![](/html/05/0516/0516d8ce522377e33b0fa9cce28ce54dd00c4fedbeb8cdb66633d3b56fa2bb56/bg1.png)
Specification Created 9/08
240 442
Listed by
Underwriters
Laboratories
PSB2200N
GE Profile Advantium® 240 Wall Oven
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Cutout width
25-1/8"
30
Required
cutout location
36-3/4"
minimum
from floor
Junction
box
location
(240-Volt
models only)
A=Allow 1" overlap of oven over top and bottom
edges of cutout.
B=Allow 11/16"-3/4" for overlap ov oven over side
edges of cutout.
4-3/16
17-1/2"
Cutout height
A
B
23-1/2"
Cutout depth
29-25/32"
21-1/2"
Excluding
Handle
Construct Solid
Bottom Min.
3/8" Plywood
Supported by
2 x 4 or 1 x 2
Runners, all
Four Sides.
(Must Support
150 lbs.)
Conduit
(48-1/2"
long)
1" Min. above toekick or adjus t
to oven installation height
2" MIN between cutout s
2-1/2" MIN bet ween cutouts
recommended—2" MIN required
9-1/4" cutout height
28-1/2" cutout width
Junction box location
A
B
A
B
Construct Solid Bottom
MIN 3/8" Plywood Suppor ted by
2 x 4 or 1 x 2 Runne rs, all Four Sides.
(Must Support 150 lbs. for Advantium)
(Must Support 200 lbs. for Wall Oven)
4-3/16
D
Excluding
Handle
H
W
Conduit
(46" long)
Cabinet width
(240-volt models only)
C
L
(Must support 130 lbs.)
2 x 4’s or
equivalent
solid floor
Suitable
bracing
to support
runners
21-5/8"
over centerline
of cabinet
A=Allow 7/8” over lap of oven over bottom and 1/4" overlap at top
edges of cutout.
B=Allow 2-1/8” for overlap of oven over side edg es of cutout.
Cabinet
Width
(inches)
W
WidthH Height
D
Depth
(excluding
handle)
X
Cutout
Width
Y
Cutout
Height
Z
Cutout
Depth
(minimum)
PSB2200/1 with out
accessory drawer
30 29-25/32 19 -1 /8 21-1 /2 25-1/8 17-1/ 2 23 -1/ 2
PSB2200/1 with
accessory drawer
30 29-25/32 2 2-1/ 4 21-3/4
25-1/8 to
28 -1 /2*
21 23 -1/ 2
*For existing cutouts a maximum width of 28-1/2" is acceptable
A=Allow 7/8” over lap of oven over bottom and 1/4" overlap at top
edges of cutout.
B=Allow 2-1/8” for overlap of oven over side edg es of cutout.
Note: Cabinets
installed adjacent
to wall ovens must
have an adhesion
spec of at least a
194°F temperature
rating.
Note: 2" minimum
between cutouts
when installed
above warming
drawer or single
wall oven.
Installation
Information:
Before installing,
consult installation
instructions packed
with product for current
dimensional data.
Advantium wall oven/GE Profile cooking tower dimensions and cabinet installation information (in inches)
![](/html/05/0516/0516d8ce522377e33b0fa9cce28ce54dd00c4fedbeb8cdb66633d3b56fa2bb56/bg2.png)
Specification Created 9/08
240 442
Listed by
Underwriters
Laboratories
PSB2200N
GE Profile Advantium® 240 Wall Oven
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Installation over a GE/Monogram
Warming Drawer:
30”
23-1/2”
25-1/4”
Min.
21”
2” Min.
(3” recommend ed)
Per w arming
drawer
requir ement
Construct
Solid Bo ttom
Min. 3/8 ”
Plywood
Supported
by 2x4 or 2x2
Runners all
Four Sid es
5” mi n.
from floor
1” mi n.
above
toeki ck
Warming Drawer:
Construct S olid
Bottom Min.
3/8” Plyw ood
Supported by
2x4 or 2 x2
Runners a ll
Four Side s
30”
23-1/2”
21”
2” Min.
Per Oven
Requirement
Per warmi ng drawer requirement
2” Min.
(3” recommen ded)
25-1/4”
Min.
5” mi n.
from floor
1” mi n.
above
toeki ck
PSB2200N
GE Profile Advantium® 240 Wall Oven
Prepare the opening
The Advantium 240V can be installed in combination with
other GE/Monogram appliances. Always follow each product's
Installation Instructions to compete the installation.
Single Advantium 240V Installation:
Order a 30" wide single oven cabinet or cut the opening in a wall
to the dimensions shown.
* For existing cutouts, a
maximum width of 28-1/2"
is acceptable. If the opening
is slightly wider, secure a
furring strip on each side of
the cutout for securing the
oven.
• Always maintain 36-3/4"
minimum height from
the floor to the cutout in
any single or combined
installation.
• Allow 3/4" to 2-1/8" case
trim overlap on the sides
and 7/8" overlap on the
bottom of the opening for
all models. The amount of overlap on the sides depends on the
actual cutout width. Allow 1-1/4" case trim overlap on the top for
models PSB2200 and PSB2201 and for models ZSC2200, ZSC2201
and ZSC2202.
• Oven overlaps will conceal cut edges on all sides of the opening.
Prepare the opening (cont.)
When installed over a single oven or a
warming drawer, allow at least 2" between
the two openings. This separation will
provide clearance for bottom overlap of the
Advantium 240V and the other appliance
overlaps.
Construct a solid oven floor of 3/8" min. thick
plywood supported by 2 x 4 or 2 x 2 runners
on all sides.
• the support must be level and rigidly
mounted, flush with the bottom edge of
the cutout.
* For existing cutouts, a maximum width of
28-1/2" is acceptable. If the opening is slightly
wider, secure a furring strip on each side of
the cutout for securing the oven.
Note: Additional clearances between the
cutouts may be required. Check to be sure the
oven supports above the Warming Drawer
location do not obstruct the required interior
depth and height. See Warming Drawer
installation instructions for details.
Installation over a GE/Monogram Oven
and Warming Drawer:
* For existing cutouts, a maximum width of
28-1/2" is acceptable. If the opening is slightly
wider, secure a furring strip on each side of
the cutout for securing the oven.
Note: Additional clearances between the
cutouts may be required. Check to be sure the
oven supports above the Warming Drawer
location do not obstruct the required interior
depth and height. See Warming Drawer
installation instructions for details.
CAUTION: For personal safety, the mounting
surface must be capable of supporting the
cabinet load, in addition to the added weight
of this approximate 80-pound oven and 30pound drawer, plus additional oven loads of up
to 50 pounds or a total weight of 160 pounds.
30”
23-1/2”
25-1/4”
Min.
21”
Construct
Base
Min. 3/8”
Plywood
Supported
by 2x4 or 2x2
Runners all
Four Sides
5” mi n.
from floor
1” mi n.
above
toeki ck
Preparation WITH an Accessory Drawer