GE Profile Advantium PSA9120SFSS, PSA9240SFSS, Profile Advantium PSA9120SF Dimension Manual

For answers to your Monogram® or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000.
Dimension Information (in inches)
this appliance must be properly grounded to avoid severe or fatal shock.
Do not, under any circumstances, cut, deform, or remove any of the prongs from the power cord. Do not use with an extension cord.
Installation Information: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
Specification Revised 7/13
240452
Listed by Underwriters Laboratories
PSA9120SF
GE Profile Series Advantium® 120 Over-the-Range Oven
66" MIN.
Mounting
height
from floor
30"
MIN.
width
required
Exhaust outlet connects to 3-1/4" X 10" duct
16-1/4"
(rear)
105°
Door open
(without obstruction)
15-1/2"
24-1/2
15-3/4"
29-7/8"
Minimum distance from door hinge side to adjacent wall should equal 1/2 inch.
13"
MAX.
12"
MIN.
For answers to your Monogram® or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000.
Dimension Information (in inches)
Hood Exhaust Duct
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard 3-1/4” x 10” rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6” diameter duct.
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with the space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of 3-1/4” x 10” rectangular or 6” diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the length of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
Specification Revised 7/13
240452
Listed by Underwriters Laboratories
PSA9120SF
GE Profile Series Advantium® 120 Over-the-Range Oven
Grille
Filter Kit Accessory
Filter Kit
JX81D–Recirculating Charcoal Filter Kit
To be used when the Advantium oven cannot be vented to the outside.
Duct Equivalent
A. Rectangular-To-Round 5 Ft.
Transition Adaptor
B. Wall Cap 40 Ft.
C. 90° Round Elbow 10 Ft.
D. 45° Round Elbow 5 Ft.
E. 90° Rectangular Elbow 25 Ft.
F. 45° Rectangular Elbow 5 Ft.
G. Roof Cap 24 Ft.
Loading...
+ 1 hidden pages