PGP9830DJ/tJ
Cabinet Dimensions (in inches)
21 7⁄8ʺ
(21
15
⁄16ʺ SS)
20
1
⁄2ʺ
22ʺ
29
3
⁄4ʺ
2
3
⁄16ʺ
(2
1
⁄4ʺ SS)
283⁄4ʺ
Cut-out Dimensions (in inches)
Note: A 5" minimum spacing to adjacent side wall is required
(29
13
⁄16ʺ SS)
GE Profile™ Series 30" Downdraft Gas Cooktop
Dimensions anD installation information
Wall I N stallat I o N: Wall installations
require 25" countertop depth. When cabinet
is flush against the wall, the fan housing can
be rotated to the horizontal position for direct
venting through rear wall. Make a countertop
cutout in the range cabinet according to unit
dimensions and installation type. Duct hole is
positioned in back of cabinet for through-thewall ducting.
PeNINsula or IslaNd INstallatIoN:
For peninsula/islands a minimum 26"countertop
depth is suggested. Blower should be in vertical
position. Island or peninsula cabinets may
require adjustment in cutout depth and/or
location within the width dimensions. Duct hole
is positioned in bottom of cabinet for island or
peninsula installation.
slab INstallatIoN: For peninsula or
island installation and rear wall ducting, 6" PVC
duct or locally approved piping should be used
if installing under a poured concrete slab.
INsta l l atIoN I N form at I oN: Before
installing, consult installation instructions,
packed with product, for current dimensional
data.
Note: These cooktops are approved for indoor
use only.
*U.L. Requirement.
25
(21
21 7⁄8ʺ
15
⁄16ʺ SS)
201⁄2ʺ
22ʺ
(29
293⁄4ʺ
13
283⁄4ʺ
⁄16ʺ SS)
(2
23⁄16ʺ
1
⁄4ʺ
20-5/8
9
C
20
L
4
10-1/2
28-7/8
1-7/8"
16
MIN. Required*
For answers to your Monogram® or GE® appliance
questions, visit our website at geappliances.com
or call GE Answer Center® service, 800.626.2000.
*Note: A 5" minimum spacing to adjacent side wall is required
Dimension and installation information are shown in inches.
Listed by
Underwriters
Laboratories
Speci fication Revise d 5/15
PGP9830DJ/tJ
Venting Options
Through Cabinet Toe Space
Inside Wall to Roof Direct to Outside
Between Floor Joist
GE Profile™ Series 30" Downdraft Gas Cooktop
Dimensions anD installation information
INstallINg the ductWork: Use
galvanized or aluminum duct in 6" round
or 3-1/4" x 10" size, or combination of
both. PVC duct or locally approved
piping should be used if installing under
a poured concrete slab. Local building
code must be followed in specifying type
and schedule of all duct used.
Note: Ductwork must be vented to
outside. Do not vent into a wall, ceiling,
crawlspace, attic or any concealed space.
Always use an appropriate roof or wall
cap with damper.
Laundry-type wall caps should never
be used. For maximum efficiency use
the shortest and straightest duct run
possible, with as few fittings as possible.
For satisfactory performance the
duct run should not exceed 100
feet equivalent length. Refer to the
table of equivalent lengths (shown in
installation instructions) for various duct
configurations.
10-1/8
6-1/8
9-1/8
18-3/4
Rear Wall VentingDownward Venting
Dimension and installation information are shown in inches.
Listed by
Underwriters
Laboratories
Speci fication Revise d 5/15