GE PFDS450GL, PFDS455GL Specification

39-3/4"
PFDS450GL/PFDS455GL
2-1/2
12
Connection
Connection
GE Profile™ Series 7.5 cu. ft. stainless steel capacity frontload dryer with Steam
Dimensions and Installation Information (in inches)
Gas Dryer Rating
120V
60Hz, 6A
Exhaust Options: 3-way via rear, right, and bottom.
Circuit Requirements: An individual, properly grounded
branch circuit, protected by a 30-amp circuit breaker or a time-delay fuse, is required.
LP Conversion Kit: WE25M46
Note: Dryer wall outlet must be located within 36”
of service cord entry and accessible when dryer is mounted in position.
Installation Information: For complete information, see installation instructions packed with your dryer.
34 3/8"
27"
RY
D
EMP
T
34 3/8"
39-3/4"
4-1/8"
3"
For answers to your Monogram,® Profile™ Series or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000.
1-3/4
Gas Pipe
3-1/2
Electrical
Specification Revised 3/13
270184
PFDS450GL/PFDS455GL
GE Profile™ Series 7.5 cu. ft. stainless steel capacity frontload dryer with Steam
Special Installation Requirements:
Stacked Installation:
• Brackets for stacking dryer over washer are available at an additional cost.
Custom built-in white installation template:
• Order Pub. No. 14-A025.
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side, 3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearance other than Alcove or Closet Installations:
• Minimum clearances to combustible surfaces 0" both sides, 3" rear.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
For answers to your Monogram,® Profile™ Series or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000.
Stacked Dimensions (in inches)
Storage Pedestal Dimensions (in inches)
SPSD157JMG - Champagne SPSD157JWW - White
This optional 15" pedestal raises the door opening and height of the washer or dryer. Feet on 15" pedestal allow it to adjust to 15­3/8" height.
27
79 1/2"
29-1/2
15
Specification Revised 3/13
270184
Loading...
+ 2 hidden pages