They are on the label on the front
of the dryer behind the door.
GE is a trademark of the General Electric Company. Manufactured under trademark license.
49-3000206 Rev 3
05-21 GEA
THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and design that goes into every GE Appliances
product, and we think you will too. Among other things, registration of your appliance ensures that we
can deliver important product information and warranty details when you need them.
Register your GE appliance now online. Helpful websites and phone numbers are available in the
Consumer Support section of this Owner’s Manual. You may also mail in the pre-printed registration
card included in the packing material.
249-3000206 Rev 3
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
WARNING
• Read all instructions before using the appliance.
•
DO NOT dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline,
dry-cleaning solvents, or other flammable or explosive substances, as they give off vapors that could ignite
or explode.
• DO NOT place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may
contribute to a chemical reaction that could cause a load to catch fire. To reduce the risk of fire due to
contaminated loads, the final part of the tumble dryer cycle occurs without heat (cool down period). Avoid
stopping a tumble dryer before the end of the drying cycle unless all items are quickly removed and spread
out so that the heat is dissipated.
• DO NOT allow children to play on or in this appliance. Close supervision of children is necessary when this
appliance is used near children.
• Before the appliance is removed from service or discarded, remove the door to the drying compartment.
• DO NOT reach into the appliance if the drum is moving.
• DO NOT install or store this appliance where it will be exposed to the weather.
• DO NOT tamper with controls.
• DO NOT climb or stand on this unit.
• DO NOT repair or replace any part of this appliance or attempt any servicing unless specifically recommended
in the user-maintenance instructions or in published user-repair instructions that you understand and have the
skills to carry out.
• Follow all fabric care instructions and warnings to prevent melting of garments or damage to the appliance.
• DO NOT use fabric softeners or products to eliminate static unless recommended by the manufacturer of the
fabric softener or product.
• DO NOT dry articles containing foam rubber or similarly textured rubber-like materials.
• Clean lint screen before or after each load.
• DO NOT operate the dryer without the lint filter in place.
• DO NOT store combustible materials, gasoline or other flammable liquids near the dryer. Keep area around
the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust and dirt.
• The interior of the appliance and exhaust duct should be cleaned periodically by qualified service personnel.
• Unplug the appliance or turn off the circuit breaker before servicing. Pressing the Power or Start/Pause pad
DOES NOT disconnect power.
• DO NOT operate this appliance if it is damaged, malfunctioning, partially disassembled, or has missing or
broken parts, including a damaged cord or plug.
• DO NOT spray any type of aerosol into, on or near dryer at any time. DO NOT use any type of spray cleaner
when cleaning dryer interior. Hazardous fumes or electrical shock could occur.
• See “ELECTRICAL CONNECTION” located in the Installation Instructions for grounding instructions.
To reduce the risk of fire, explosion, electric shock, or injury to persons when using your
appliance, follow basic precautions, including the following:
SAFETY INFORMATION
READ AND SAVE THESE INSTRUCTIONS
49-3000206 Rev 33
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
ADDITIONAL GAS DRYER WARNINGS
WARNING
Failure to follow safety warnings exactly could result in serious injury, death, or property
damage.
- DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of
this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
• DO NOT try to light any appliance.
SAFETY INFORMATION
• DO NOT touch any electrical switch; DO NOT use any phone in your building.
• Clear the room, building, or area of any occupants.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
- Fire or Explosion Hazard
449-3000206 Rev 3
Getting started
Quick Start
USING THE DRYER
WARNING
WARNING
• Keep flammable materials and vapors, such as
gasoline, away from dryer.
• DO NOT dry anything that has ever had anything
flammable on it (even after washing).
• No washer can completely remove oil.
To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY
INFORMATION before operating this appliance.
- Fire Hazard
• DO NOT dry anything that has ever had any type of oil
on it (including cooking oils).
• Items containing foam, rubber, or plastic must be dried
on a clothesline.
• Failure to do so can result in death, explosion, or fire.
Throughout this manual, features and appearance will vary from your model.
WiFi Connect (For customers in the United States only - on some models)
Your dryer is GE Appliances WiFi Connect enabled.
Visit geappliances.com/connect and enter your model number to
show you the proper steps to connect your appliance.
Please visit GEAppliances.com/connect to learn more about
connected appliance features, to learn what connected appliance
App’s will work with your smartphone.
WiFi Connectivity: For assistance with the appliance or the
ConnectPlus network connectivity, please call GE Appliances at
800.220.6899.
WiFi Label Location
:
Step 1
• Clean lint filter
• Loosely add items.
• Close door.
NOTE: Dryer will not
start with door open.
Step 2Step 3
• If the screen is dark,
press the Power pad
to “wake up” the
display.
• Select a sensor dry cycle.
(Defaults are set for each dry
cycle. These default settings
can be changed. See the cycle
descriptions for more information.)
• Select TIMED DRY and set Time,
Temp and Level.
Step 4
• Press the Start/
Pause pad.
OR
49-3000206 Rev 35
Getting started
Features and appearance will vary.
Model:
PFD95
USING THE DRYER
Model:
GFD85
Model:
GFD65
DA
C
BFFE
CDA
BFFE
CDA
BFFE
Models:
GFD55
GFV55
DA
C
BFFE
Model:
HFD35
CDA
BFFE
649-3000206 Rev 3
Getting started
Power
A
Press to “wake up” the display. If the display is active, press to put the dryer into idle mode.
NOTE: Pressing Power does not disconnect the appliance from the power supply.
Start and Pause
B
Press Start to begin the cycle. NOTE: The door must be closed for the dryer to start the cycle. Pressing Start
again will pause the cycle, the Start light may blink and “Pause” will display.
To continue the cycle, press Start again.
Display and Status Lights
C
The display shows the approximate time remaining until the end of the cycle. On some models, the dryer cycle
status (Sense, Drying, Damp and Cool) will be shown.
In addition, the display will show:
USING THE DRYER
(WiFi)
(on some models)
Controls
Check FilterThe Check Filter light will stay on for 15 seconds after the cycle stops.
Check Vent
(on some models)
Will allow your appliance to communicate with your smartphone for remote appliance
monitoring control and notifications.
The dryer is locked - will blink once if you press any pad or turn the cycle knob.
The Check Vent light indicates an issue has been found due to reduced airflow from a possible
blocked or restricted vent. Checking and/or cleaning the vent system is recommended. See the,
“Check Vent” light is on in the Troubleshooting Tips section.
Your dryer is equipped with Artificial Intelligence capabilities. This indicator will illuminate when
Washer Link is active, My Settings are being implemented based on your usage habits and
suggested actions are available through the SmartHQ app.
49-3000206 Rev 37
Getting started
D
USING THE DRYER
Drying
Cycles
MIXED LOADS
COTTONSFor cottons and most linens. NOTE: ENERGY STAR® models are tested on COTTONS cycle
TOWELS
(on some models)
BULKY
Bedding
SANITIZE
(on some models)
WASHER
LINK (on
some models)
ACTIVE
WEAR
(on some models)
QUICK DRYFor small loads that are needed in a hurry, such as sport or school uniforms. Can also be
DELICATESFor delicate items, special-care fabrics and knits.
PERM PRESS
(on some models)
AIR FLUFF
(on some models)
DEWRINKLE
(on some models)
STEAM
Dewrinkle
(on some models)
STEAM
Refresh
(on some models)
STEAM
SANITIZE
(on some models)
Sensor cycles automatically determine fabric dryness.
Timed cycles run for the selected time.
For loads consisting of cottons and poly-blends.
with default settings (Temp setting on High, Level setting on Dry, and ecoDry default on).
For most towels and linens.
For large coats, bed spreads, mattress covers, sleeping bags, and similar large/bulky items
such as blankets, comforters, jackets, and small rugs.
This option reduces certain types of bacteria including: Staphylococcus aureus, Pseudomonas
aeruginosa and Klebsiella pneumoniae. The anti-bacterial process occurs when high heat is
used during a portion of the drying cycle; cool down also will be longer to protect you from a
hot garment.
NOTE: Do not use this cycle on delicate fabrics.
When selected (and if connected to a compatible washer through WiFi communication)
the dryer receives load information from the washer to automatically make cycle, dryness,
temperature and time recommendations to optimize drying.
Clothing worn for active sports exercise and some casual wear. Fabrics include new
technology finishes and stretch fibers such as Spandex. Also for clothing labeled Easy Care or
Perma Press: For wrinkle-free and permanent press items.
used if the previous cycle left some items damp, such as collars or waistbands. NOTE: On
some models, the time remaining in the cycle will show counting down in the display.
For wrinkle-free, permanent press and special sports items that need extra drying care.
Provides 10 minutes of tumbling time with no heat. NOTE: On models with AIR FLUFF cycle,
select TIMED DRY and set Temp to No Heat.
For removing wrinkles from items that are dry or slightly damp. This cycle is not recommended
for delicate fabrics.
For use with larger loads than STEAM Refresh. Ideal for loads left in the dryer for an
extended time.
STEAM Dewrinkle is recommended for larger loads (9-13 garments).
NOTE: Steam cycles are not intended for use with towels.
Important - The temperature setting must be set to High and water must be turned on
before running the STEAM Dewrinkle cycle.
For slightly wrinkled dry garments. Significantly reduces wrinkles. After the STEAM Refresh
cycle, the unit will beep (if Sound is selected) and display “00.”
STEAM Refresh is recommended for small loads (3-5 garments).
NOTE: Steam cycles are not intended for use with towels.
NOTE: A single extremely light fabric item may need to have an additional item included in the
STEAM Refresh cycle to achieve optimum results.
Important - The temperature setting must be set to High and water must be turned on
before running the STEAM Refresh cycle.
For use with standard size loads, which damp from washing and/or rinsing, in which you would
like to sanitize and remove wrinkles set in from high speed spins. This cycle reduces certain
types of bacteria including: Staphylococcus aureus, Pseudomonas aeruginosa and Klebsiella
pneumoniae. This anti-bacterial process occurs when high heat is used during a portion of the
drying cycle.
NOTE: Do not use this cycle on delicate fabrics.
Important - The temperature setting must be set to High and water must be turned on
before running the STEAM SANITIZE cycle.
849-3000206 Rev 3
Getting started
USING THE DRYER
Drying
D
Cycles
TIMED DRY
Settings
E
Individual settings for cycle minutes (Time), dryness level (Level) and temperature (Temp) can be set from the
minimum (lowest in column) to maximum (highest in column). In general, the higher up the column, the more
energy will be used. NOTE: The selected cycle set Time can be further adjusted, in one minute increments, by
pressing the More Time + and Less Time - pads.
Dryness Level - Selection only used for Sensor cycles. Timed cycles run for the selected time.
NOTE: Options for Dryness Levels vary by model. Refer to the control panel on your model or to the control
panels shown earlier in this manual.
Extra DryUse for heavy-duty fabrics or items that should be very dry, such as towels.
More DryUse for heavy-duty or mixed type fabrics.
DryUse for a normal dryness level suitable for most loads. This is the preferred cycle for energy
Less Dry Use for lighter fabrics.
DampFor leaving items partially damp.
Temperature
HighFor regular to heavy cottons.
MediumFor synthetics, blends, delicates and items labeled permanent press.
Low For delicates, synthetics and items labeled tumble dry low.
Extra LowFor lingerie and special-care fabrics.
No HeatFor fluffing items without heat. For use only with the AIR FLUFF cycle.
Sensor cycles automatically determine fabric dryness.
Timed cycles run for the selected time.
Use to set your own dry time. To use:
1. Turn cycle dial to TIMED DRY.
2. Increase the drying time by pressing the Time pad.
NOTE: This pad only increases the time. When max time is reached, pressing the pad again
will reset the counter to the lowest setting.
3. Select the Temp.
4. Close the door.
5. Press Start/Pause pad.
savings.
NOTE: STEAM Dewrinkle and STEAM Refresh require the High temperature setting.
49-3000206 Rev 39
Getting started
Options
F
Reduce Static (on some models)
When selected, the dryer will spray a mist of water onto the load, at the end of the drying cycle, to reduce static.
This option is not available with BULKY, SANITIZE or STEAM cycles.
Damp Alert (Damp Alert/WiFi pad) (on some models)
This option causes the dryer to beep when clothes have dried to a damp level. Remove items that you wish
to hang dry. The Damp Alert will only beep when this option is selected (but the dry cycle will keep running).
Removing clothes and hanging them when they are damp, can reduce the need to iron some items.
Delay Dry
USING THE DRYER
Press the Delay Dry pad to set the delay start time in 1 hour increments up to 24 hours, and then back to clear
(0 hours). After selecting the delay start time, press Start and the delay time will count down the time remaining
until the cycle starts. NOTE: To set the amount of delay time faster, you can press and hold the Delay Dry pad.
Delay Dry for WiFi Connected Dryers
You have two options to set Delay Dry using your smartphone.
Option 1: Follow Delay Dry instructions. You can use the GE Appliances Laundry App to adjust the amount of
time via your smartphone.
Option 2 - Remote Start: Set your dryer to “AP” using the Delay Dry pad. This allows you to use the GE Appliances
Laundry App via your smartphone to start your dryer remotely at the time of your choosing. If the dryer is set to
AP with no activity, it will start the dryer 24 hours later.
Air Fluff (on some models)
Provides 10 minutes of tumbling time with no heat. NOTE: On models without AIR FLUFF cycle, select TIMED
DRY and set Temp to No Heat.
Sound (on some models)
Use the Sound pad to change the volume of the pad presses and the end of cycle signal. Press the pad until
you reach the desired volume or off. The clothes should be removed when the end of cycle signal goes off so
wrinkles do not set in.
NOTE:
• Remove garments promptly at the sound of signal. Place clothes on hangers so wrinkles will not set in.
• Use the Sound especially when drying fabrics like polyester, knits and permanent press. These fabrics should
be removed so wrinkles will not set in.
Wrinkle Care
Use this option to minimize the wrinkles in clothes. It provides 1 hour of no-heat tumbling after the clothes are
dry. If you are using the cycle Sound and you select the Wrinkle Care option, a signal will sound at the end of
the drying time and several times during the Wrinkle Care cycle. This will remind you that it is time to remove
the clothes.
More Time + / Less Time -
The selected cycle set Time can be further adjusted, in one minute increments, by pressing the More Time +
and Less Time - pads.
ecoDry
Available for BULKY, TOWELS, COTTONS, MIXED LOADS, ACTIVE WEAR and DELICATES. When the
ecoDry pad is pressed, cycle settings change to reduce the total energy consumption of the selected sensor cycle. NOTE: Cycle times will change when ecoDry is selected. The ecoDry option will default to on for
COTTONS. For optimal energy savings, turn ecoDry on. For optimal drying times, turn ecoDry off.
NOTE: Energy savings will vary across loads and cycles.
1049-3000206 Rev 3
Getting started
Options (cont.)
F
Light (on some models)
The drum light will turn on if the Light pad is pressed or the door is opened. It will turn off when the door is shut,
the Light pad is pressed again or after 5 minutes if the door is left open.
Small Load (on some models)
Select to use for a small load with any sensor cycle (except SANITIZE).
My Settings (on some models)
As the cycle selector knob is turned, the Time (timed dry), Level (dryness level) and Temp (temperature)
settings change to automatic pre-set default settings. If you desire a different setting, press the appropriate
pad(s). Then press and hold the My Settings pad for 3 seconds and the dryer will “remember” these settings
for that Knob Selection. In the future, when you turn the selector knob to that cycle, your settings will be
automatically recalled.
NOTE: Signal sound cannot be set for My Settings.
NOTE: On models equipped with AI (Artificial Intelligence), My Settings may be set automatically based on
your usage habits. If you would like to reset this, press and hold MY Settings to clear the memory.
Control Lock
You can lock the controls to prevent any selections from being made. Or you can lock the controls after you
have started a cycle. Children cannot accidentally start the dryer by touching pads with this option selected.
To lock/unlock the dryer controls, press and hold the Light pad for 3 seconds. The control lock icon will flash
while locking/unlocking, stay on when locked, and turn off when unlocked.
NOTE: The Power pad can still be used when the machine is locked.
USING THE DRYER
WiFi (Damp Alert/WiFi pad)
Press and hold the Damp Alert/WiFi pad for 3 seconds to activate.
49-3000206 Rev 311
Loading
Always follow fabric manufacturer’s care label when laundering.
Sorting and Loading Hints
WARNING
• Keep flammable materials and vapors, such as
gasoline, away from dryer.
• DO NOT dry anything that has ever had anything
flammable on it (even after washing).
• No washer can completely remove oil.
USING THE DRYER
As a general rule, if clothes are sorted properly for the washer, they are sorted properly for the dryer. Try also to sort
items according to size. For example, do not dry a sheet with socks or other small items.
Do not add fabric softener sheets once the load has become warm. They may cause fabric softener stains. Bounce®
Fabric Conditioner Dryer Sheets have been approved for use in this dryer when used in accordance with the
manufacturer’s instructions.
Do not overload. This wastes energy and causes wrinkling.
- Fire Hazard
• DO NOT dry anything that has ever had any type of oil
on it (including cooking oils).
• Items containing foam, rubber, or plastic must be dried
on a clothesline.
• Failure to do so can result in death, explosion, or fire.
Drying Rack(Available as an option)
A handy drying rack may be used for drying delicate items such as washable sweaters.
To install the drying rack, place the rack all the way into the dryer drum and fit its feet down and securely into place
in the dryer.
NOTES:
• The drying rack must be used with the TIMED DRY cycle. Use with sensor cycles may
result in damp items or extended cycle times.
• Do not use this drying rack when there are other clothes in the dryer.
• If your model did not come with a drying rack, order WE02X29449 on-line at
GEApplianceparts.com, 24 hours a day or by phone at 877.959.8688 during normal
business hours.
1249-3000206 Rev 3
Care and cleaning
Interior and Duct
The interior of the appliance and exhaust duct should be cleaned once a year by qualified service personnel.
The Exhaust Duct: Inspect and clean the exhaust ducting at least once a year to prevent clogging. A partially clogged
exhaust can lengthen the drying time.
Follow these steps:
1
Turn off electrical supply by disconnecting the plug from the wall socket.
2
Disconnect the duct from the dryer.
3
Vacuum the duct with the hose attachment and reconnect the duct.
The Exhaust Hood: Check with a mirror that the inside flaps of the hood move freely when operating. Make sure that there
is no wildlife (birds, insects, etc.) nesting inside the duct or hood.
Exterior
Wipe or dust any spills or washing compounds with a damp cloth. Dryer control panel and finishes may be damaged
by some laundry pretreatment soil and stain remover products. Apply these products away from the dryer. The fabric
may then be washed and dried normally. Damage to your dryer caused by these products is not covered by your
warranty.
CARE AND CLEANING
Lint Filter
Clean the lint filter before each use.
Remove by pulling straight up. Run your fingers across the filter. A waxy buildup may form
on the lint filter from using dryer added fabric softener sheets.
To remove this buildup, wash the lint screen in warm, soapy water. Dry thoroughly and
replace.
Vacuum the lint from the dryer lint filter area if you notice a change in dryer performance.
NEVER OPERATE THE DRYER WITHOUT ITS FILTER IN PLACE.
Stainless Steel (on GFD85 & PFD95 models only)
The stainless steel used to make the dryer drum provides the highest reliability available in a GE Appliances dryer.
If the dryer drum should be scratched or dented during normal use, the drum will not rust or corrode. These surface
blemishes will not affect the function or durability of the drum.
To clean stainless steel surfaces use a damp cloth with a mild, non-abrasive cleaner suitable for stainless steel
surfaces. Remove the cleaner residue and then dry with a clean cloth.
Alcosta Aluminized Steel (on all other models)
The steel used to make the dryer drum has an aluminized coating on its surface to prevent it from rusting or
corroding. Any surface blemishes will not affect the function or durability of the drum.
To clean the Alcosta surface use a damp cloth with a mild, non-abrasive cleaner suitable for stainless steel surfaces.
Remove the cleaner residue and then dry with a clean cloth.
Drum Light (on some models)
The drum light is an LED light. Replacement must be done by a qualified technician.
49-3000206 Rev 313
Installation
Instructions
If you have any questions, call GE Appliances at 800.GE.CARES
(800.432.2737)
In Canada, call 800.561.3344
BEFORE YOU BEGIN
Read these instructions completely and carefully.
orvisit our Website at: GEAppliances.com
orvisit www.GEAppliances.ca
WARNING
Dryer
• IMPORTANT– Save these instructions for
local electrical inspector’s use.
•IMPORTANT – Observe all governing
codes and ordinances.
• Install the clothes dryer according to the
manufacturer’s instructions and local codes.
• Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions for
future reference.
• Clothes dryer installation must be performed by a
qualified installer.
• This dryer must be exhausted to the outdoors.
• Before the old dryer is removed from service or
discarded, remove the dryer door.
• Service information and the wiring diagram are
located in the control console.
• Do not allow children on or in the appliance. Close
supervision of children is necessary when the
appliance is used near children.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not
covered under the Warranty.
• Install the dryer where the temperature is above
50°F for satisfactory operation of the dryer control
system.
• Remove and discard existing plastic or metal foil
duct and replace with UL-listed duct.
If you are planning to stack the washer and dryer, order
Stacking Kit number GFA28KITN to be used for this
dryer. Kit sold separately.
- Risk of Fire
• Clothes dryer installation must be performed by a
qualified installer.
• Install the clothes dryer according to these
instructions and local codes.
• DO NOT install a clothes dryer with flexible plastic
venting materials. If flexible metal (semi-rigid or
foil-type) duct is installed, it must be UL-listed and
installed in accordance with the instructions found
in “Connecting the Dryer to House Vent” later in
this manual. Flexible venting materials are known
to collapse, be easily crushed and trap lint. These
conditions will obstruct dryer airflow and increase
the risk of fire.
• DO NOT install or store this appliance in any
location where it could be exposed to water or
weather.
• To reduce the risk of severe injury or death, follow
all installation instructions.
• Save these instructions. (Installers: Be sure to
leave these instructions with the customer.)
FOR GAS DRYERS ONLY
In the Commonwealth of Massachusetts,
the following installation instructions apply:
• Installation must be performed by a qualified or
licensed contractor, plumber, or gasfitter qualified
or licensed by the State.
• If using a ball valve, it shall be a T-handle type.
• A flexible gas connector, when used, must not
exceed 4 feet (1.2 m).
1449-3000206 Rev 3
Installation Instructions
UNPACKING YOUR DRYER
Tilt the dryer sideways and remove the foam shipping pads by pulling at the sides and breaking
them away from the dryer legs. Be sure to remove all of the foam pieces around the legs.
Remove the bag containing the literature.
DRYER
28”
(71.2 cm)
DIMENSIONS
*39-3/4”
(101 cm)
Front View
*NOTE: With leveling legs retracted: 39-3/4 (101 cm). With leveling legs fully extended: 40-5/8 (103.1 cm).
With Optional Pedestal: 55-1/2” (141 cm) Min. - 56-5/8” (143.8 cm) Max.
Stacked: 79-1/8” (201 cm).
STEAM WATER HOSES (for steam dryer models only):
GE Appliances strongly recommends the use of factory
specified parts. These hoses are manufactured and tested
to meet GE Appliances specifications.
GE Appliances strongly recommends the use of new water
supply hoses. Hoses degrade over time and need to be
replaced every 5
and water damage.
Parts and Accessories
Order on-line at GEApplianceparts.com, 24 hours a day
or by phone at 877.959.8688 during normal business hours.
years to reduce the risk of hose failures
Part NumberAccessory
WE25X20060
WE49X25794
WE1M847Long Hose
OR SEPARATELY
WE1M847Long Hose and
WE1M848Short Hose
Complete Kit (hoses, Y-adapter, washers)
or
Kit (Short hose, Y-adapter, washers)
and
54-1/4” (137.8 cm)
31-3/8” (79.7 cm)
Side View
ACCESSORIES:
Order on-line at GEApplianceparts.com, 24 hours a day or
by phone at 877.959.8688 during normal business hours.
Part NumberAccessory
GFR0728SNWW
GFR0728PNSN
GFR0728PNRS Royal Sapphire Riser
GFR0728PNDG
GFR0728PTDS Black Slate Riser
49-3000206 Rev 315
White Riser
Satin Nickel Riser
Diamond Gray Riser
Part NumberAccessory
GFA28KITNStacking Kit for Dryer over Washer
GFA28DSVN
(WE16X29317)
PM08X10085
WE02X29449
GFP1528SNWW
GFP1528PNSN
GFP1528PNRS Royal Sapphire Pedestal
GFP1528PNDG Diamond Gray Pedestal
GFP1528PTDS Black Slate Pedestal
Dryer Venting Kit
Flexible Metal Dryer Transition Duct
Clothes Dryer Drying Rack
White Pedestal
Satin Nickel Pedestal
Installation Instructions
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
WARNING
Keep flammable materials and vapors, such as gasoline,
away from dryer.
Place dryer at least 18” (46 cm) above the floor for a
garage installation.
Failure to do so can result in death, explosion, or fire.
• The dryer MUST be vented to the outdoors.
• Minimum clearance between dryer cabinet and
adjacent walls or other surfaces is:
0” (0 cm) either side*0” (0 cm) front
0” (0 cm) rear
0”
*For improved performance, a 1/2” (12.7 mm)
clearance is suggested on each side.
• The rear of the dryer should face a wall.
• Consideration must be given to provide adequate
clearance for installation and service.
• Closet doors must be louvered or otherwise
ventilated and have at least 60 square inches (387
cm2) of open area. If the closet contains both a
washer and a dryer, doors must contain a minimum
of 120 square inches (774 cm2) of open area.
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT
THE REAR OF THE DRYER, THE CONFIGURATION
OF THE DUCTING MAY REQUIRE GREATER
CLEARANCE.
Gas Dryers Only:
• No other fuel burning appliance shall be installed in
the same closet as a gas dryer.
• The dryer must be disconnected from the gas
supply piping during pressure testing at pressures
greater than 1/2 psi (3.5 kPa).
• A 1/8” (3.2 mm) NPT minimum plugged tapping,
accessible for test gauge connection, must be
installed immediately upstream of the gas supply
connection to the dryer.
(0 cm)
- Explosion Hazard
top
MINIMUM CLEARANCE OTHER
THAN ALCOVE OR CLOSET
INSTALLATION
Minimum clearance to combustible surfaces and for
air opening are: 0” (0 cm) both sides*, 0” (0 cm) rear
and 0” (0 cm) top.
*For improved performance, a 1/2” (12.7 mm)
clearance is suggested on each side.
The rear of the dryer should face a wall.
Consideration must be given to provide adequate
clearance for installation and service.
MOBILE OR MANUFACTURED
HOME INSTALLATION
• Installation MUST conform to the
MANUFACTURED HOME CONSTRUCTION
AND SAFETY STANDARD, TITLE 24, PART
3280 or STANDARD FOR MOBILE HOMES
CAN/CSA-Z240 MH, or, when such standards
are not applicable, with AMERICAN NATIONAL
STANDARD FOR MOBILE HOME, ANSI/NFPA
NO. 501B.
• The dryer MUST be vented to the outdoors.
• The exhaust vent MUST be securely fastened to a
non-combustible portion of the mobile home.
• The vent MUST NOT be terminated beneath a
mobile or manufactured home.
• The vent duct material MUST BE METAL.
• KIT 14-D346-33 MUST be used to attach the dryer
securely to the structure.
• The vent MUST NOT be connected to any other
duct, vent or chimney.
• DO NOT use sheet metal screws or other
fastening devices which extend into the interior of
the exhaust vent.
• Provide an opening with a free area of at least 25
square inches (63 cm
air into the dryer room.
• See the sections for electrical connection information.
To produce steam, the dryer must connect to
the cold water supply. Since the washer must
also connect to the cold water, a “Y” connector
is inserted to allow both inlet hoses to make that
connection at the same time.
NOTE: Use new inlet hoses; never use old
hoses.
1. Turn the cold water faucet off. Remove the
washer inlet hose from the washer fill valve
connector (cold).
2. Ensure the rubber flat washer is in place and
attach one female coupling of the short hose
provided onto the washer fill valve connector.
Tighten by hand until firmly seated.
3. Attach one male end of the “Y” connector to
the other female coupling of the short hose.
Ensure the rubber flat washer is in place.
Tighten by hand until firmly seated.
CONNECTING INLET HOSES (cont.)
7. Using pliers, tighten all the couplings with an
additional two–thirds turn.
NOTE: Do not overtighten. Damage to the
couplings may result.
8. Turn the water faucet on.
9. Check for leaks around the ‘’Y’’ connector,
faucet and hose couplings.
4. Insert the filter screen in the coupling of the
washer’s inlet hose. If a rubber flat washer is
already in place remove it before installing the
filter screen. Attach this coupling to one male
end of the ‘’Y’’ connector. Tighten by hand until
firmly seated.
5. Ensure the rubber flat washer is in place
and attach a 4 ft. (1.2 m) to 6 ft. (1.8 m) long
water inlet hose (may need to be purchased
separately) to one male end of the ‘’Y’’
connector. Tighten by hand until firmly seated.
6. Ensure the rubber flat washer is in place and
attach the other end of the dryer’s long inlet
hose to the fill valve connector at the bottom
of the dryer back panel. Tighten by hand until
firmly seated.
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUST be installed
within 42 in. (107 cm) of your washer’s water
inlet. The faucets MUST be 3/4” (19.1 mm)
garden hose-type so inlet hoses can be
connected. Water pressure MUST be between
10 and 120 pounds per square inch. Your
water department can advise you of your water
pressure.
NOTE: A water softener is recommended
to reduce buildup of scale inside the steam
generator if the home water supply is very hard.
49-3000206 Rev 317
Installation Instructions
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
CONNECTING A GAS DRYER (skip for electric dryers)
TOOLS YOU WILL NEED
Ŷ
10” (25.40 cm)
Adjustable wrenches (2)
Ŷ
8” (20.32 cm)
Pipe wrench
Ŷ
Flat-blade
screwdriver
Ŷ
Slip-joint pliers
Ŷ
Level
MATERIALS YOU WILL NEED
Ŷ
GFA28DSVN Kit
(All parts included in
this Kit or parts may be
purchased separately)
Ŷ
Access Panel
Ŷ
4” (10.2 cm) dia. metal
elbow
Exhaust hood
Ŷ
Pipe compound or
PTFE tape
Ŷ
Flexible gas line
connector
• Before beginning the installation, turn off the circuit
breaker(s) or remove the dryer’s circuit fuse(s) at
the electrical box. Be sure the dryer
cord is unplugged from the wall.
• Turn the dryer’s gas shut-off valve in the supply line
to the OFF position.
Shut-off
Valve
Ŷ
4” (10.2 cm) dia. metal
duct (recommended)
Ŷ
4” (10.2 cm) Duct
clamps (2) or 4” (10.2
cm) spring clamps (2)
Ŷ
4” (10.2 cm) dia.,
UL-listed flexible
metal duct (if needed)
Ŷ
Duct tape
Ŷ
Gas pipe adapters (2),
elbow and pipe plug
Ŷ
Soap solution for
leak detection
Ŷ
Gloves
Ŷ
Safety glasses
• Disconnect and discard old flexible gas connector
and ducting material.
1849-3000206 Rev 3
Installation Instructions
CONNECTING A GAS DRYER (cont.)
GAS REQUIREMENTS
WARNING
• Use a new CSA International approved flexible
gas supply line. Never reuse old flexible
connectors.
• Install an individual manual shut-off valve
within 6ft. of the dryer in accordance with the
National Fuel Gas Code, ANSI Z223.1/NFPA
54.
• Securely tighten all gas connections.
• If connected to LP gas, have a qualified
person make sure gas pressure DOES NOT
exceed 13” (33 cm) water column.
• Examples of a qualified person include:
licensed heating personnel, authorized gas
company personnel, and authorized service
personnel.
• Failure to do so can result in death,
explosion, or fire.
• The installation must conform with local
codes, or in the absence of local codes, with
the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or the Natural Gas and Propane
Installation Code, CSA B149.1.
- Explosion Hazard
GAS SUPPLY
• A 1/8” (3.2 mm) National Pipe Taper thread
plugged tapping, accessible for test gauge
connection, must be installed immediately
upstream of the gas supply connection to the
dryer. Contact your local gas utility should you
have questions on the installation of the plugged
tapping.
• Supply line is to be 1/2” (12.7 mm) rigid pipe and
equipped with an accessible shutoff within 6 feet
(1.8 m) of, and in the same room with, the dryer.
• Use pipe thread compound appropriate for
natural or LP gas or use PTFE tape.
• Connect flexible metal connector to dryer and
gas supply.
WARNING
FOR USE WITH NATURAL GAS ONLY
Dryer as produced by manufacturer is to be used
only with a natural gas supply. A manufacturersupplied conversion kit is required to convert this
dryer for propane gas supply. Use propane
conversion kit WE25M87
made by properly trained and qualified personnel
in accordance with local codes and ordinances.
- Fire Hazard
gas
. Conversion must be
DRYER GAS SUPPLY CONNECTION
1-5/8” (4.16 cm)
5-3/4”
(14.57 cm)
You must use with this dryer a flexible metal connector
(listed connector ANSI Z21.24 / CSA 6.10). The length
of the connect shall not exceed 4 ft. (1.2 m).
49-3000206 Rev 319
NOTE: Add to vertical dimension the
GLVWDQFHEHWZHHQFDELQHWERWWRPWRÀRRU
3/8” (9.6 mm) NPT
MALE THREAD
GAS SUPPLY
ADJUSTING FOR ELEVATION
• Gas clothes dryers input ratings are based on
sea level operation and need not be adjusted for
operation at or below 2000 ft. (610 m) elevation.
For operation at elevations above 2000 ft. (610 m),
input ratings should be reduced at a rate of 4
percent for each 1000 ft. (305 m) above sea level.
• Installation must conform to local codes and
ordinances or, in their absence, the NATIONAL
FUEL GAS CODE, ANSI Z223.
Installation Instructions
CONNECTING A GAS DRYER (cont.)
CONNECTING THE DRYER TO
THE GAS SUPPLY
Install a female 3/8” (9.6 mm) NPT elbow at
A
the end of the dryer gas inlet.
Install a 3/8” (9.6 mm) flare union adapter to
the female elbow.
IMPORTANT: Use a pipe wrench to securely
hold on to the end of the dryer gas inlet to
prevent twisting the inlet.
NOTE: Apply pipe compound or PTFE tape to
the threads of the adapter and dryer gas inlet.
New Metal
Flexible Gas
Line Connector
Adapter
Elbow
Items not supplied
Attach the flexible metal gas line connector to
B
3/8” (9.6 mm)
NPT
the adapter.
Adapter
1/8” (3.2 mm)
NPT Pipe Plug
for Checking
Gas Inlet
Pressure
Shut-Off Valve
Pipe size at
least 1/2” (12.7
mm)
CONNECTING THE DRYER TO
THE GAS SUPPLY (cont.)
Install a 1/8” (3.2 mm) NPT plugged tapping
D
to the dryer gas line shut-off valve for
checking gas inlet pressure.
Install a flare union adapter to the plugged
tapping.
NOTE: Apply pipe compound or PTFE tape
to the threads of the adapter and plugged
tapping.
Apply pipe compound
or PTFE tape to all
male threads.
Shut-Off
Valve
Tighten all connections, using two adjustable
E
wrenches. Do not overtighten.
Plugged
Tapping
Apply pipe compound to the
adapter and dryer gas inlet.
Tighten the flexible gas line connection, using
C
two adjustable wrenches.
Open the gas shut-off valve.
F
2049-3000206 Rev 3
Installation Instructions
CONNECTING A GAS DRYER (cont.)
TEST FOR LEAKS
Never use an open flame to test for gas leaks.
Check all connections for leaks with soapy solution or
equivalent.
Apply a soap solution. The leak test solution must not
contain ammonia, which could cause damage to the
brass fittings.
If leaks are found, close the valve, retighten the joint
and repeat the soap test.
Open Gas
Valve
ELECTRICAL CONNECTION
INFORMATION FOR GAS DRYERS
WARNING
Plug into a grounded 3 prong outlet.
DO NOT remove ground prong.
DO NOT use an adapter.
DO NOT use an extension cord.
Failure to do so can result in death, fire or
electrical shock.
• Circuit – Individual properly polarized and grounded
15 or 20 amp circuit breaker or time-delay fuse.
• Power Supply – 2-wire plus ground, 120 Volt, single
phase, 60 Hz, alternating current.
• Outlet Receptacle – Properly grounded 3-prong
receptacle to be located
so the power cord is
accessible when the dryer
is in an installed position.
If a 2-prong receptacle is
present, it is the owner’s
responsibility to have a
licensed electrician replace
it with a properly grounded 3-prong grounding type
receptacle.
- Electrical Shock Hazard
Ensure proper
ground exists
before use.
ELECTRICAL CONNECTION
INFORMATION FOR GAS DRYERS
(cont.)
• Dryer must be electrically grounded in accordance
with local codes and ordinances, or in the absence
of local codes, with the latest edition of the
NATIONAL ELECTRICAL CODE, ANSI/NFPA
NO. 70 or CANADIAN ELECTRICAL CODE, CSA
C22.1. Check with a licensed electrician if you are
not sure that the dryer is properly grounded.
GROUNDING INSTRUCTIONS
This dryer must be grounded. In the event of a
malfunction or breakdown, grounding will reduce
the risk of electric shock by providing a path of
least resistance for electric current. This dryer
uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is
properly installed and grounded in accordance
with all local codes and ordinances.
WARNING
can result in a risk of electric shock. Check with a
qualified electrician, or service representative or
personnel, if you are in doubt as to whether the
appliance is properly grounded. DO NOT modify
the plug on the power supply cord. If it will not
fit the outlet, have a proper outlet installed by a
qualified electrician.
SAVE THESE INSTRUCTIONS
• If required by local codes, an external 18 gauge
or larger copper ground wire (not provided) may
be added. Attach to dryer cabinet with a #8-18 x
1/2” (12.7 mm) sheet metal screw (available at any
hardware store) to rear of dryer as illustrated.
Ground
Screw
Improper connection of the
equipment-grounding conductor
49-3000206 Rev 321
Installation Instructions
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
Ŷ
CONNECTING AN ELECTRIC DRYER
(Skip for gas dryers and if your dryer already has a power cord attached)
TOOLS YOU WILL NEED
Slip-joint pliers
Flat-blade
screwdriver
Phillips
screwdriver
Level
MATERIALS YOU WILL NEED
Ŷ
GFA28DSVN Kit
(All parts included in
this Kit or parts may be
purchased separately)
Ŷ
Access Panel
Ŷ
4” (10.2 cm) dia. metal
elbow
Ŷ
4” (10.2 cm) dia. metal
duct (recommended)
Ŷ
4” (10.2 cm) Duct
clamps (2) or 4” (10.2
cm) spring clamps (2)
Ŷ
4” (10.2 cm) dia.,
UL-listed flexible
metal duct (if needed)
Ŷ
Duct tape
Exhaust hood
Ŷ
Metal strain relief
clamp (UL recognized)
Ŷ
Dryer power cord kit
(not provided with
dryer)
UL rated 120/240V,
30A with 3 or 4 prongs.
Identify the plug type
as per the house
receptacle before
purchasing line cord.
Stacking installations
may require a power
cord up to 6 feet
(1.8 m) in length.
Ŷ
Gloves
Ŷ
Safety glasses
Before making the electrical connection, turn off the
circuit breaker(s) or remove the dryer’s circuit fuse(s) at
the electrical box. Be sure the dryer cord is unplugged
from the wall. NEVER LEAVE THE ACCESS COVER
OFF THE TERMINAL BLOCK.
WARNING
Disconnect power supply before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
- Electrical Shock Hazard
POWER CORDS
GE Appliances strongly recommends the use of
factory specified parts. Select the power cord to fit your
installation requirements.
NOTE: If your dryer circuit is on a circuit protected by a
GFCI breaker, then 3-wire installation is not permitted.
House wiring and dryer must be configured for 4-wire.
Part NumberTypeLengthAmperage
WX9X23-Prong4 ft. (1.2 m)30
WX9X33-Prong5 ft. (1.5 m)30
WX9X43-Prong6 ft. (1.8 m)30
WX9X184-Prong4 ft. (1.2 m)30
WX9X194-Prong5 ft. (1.5 m)30
WX9X204-Prong6 ft. (1.8 m)30
Order on-line at GEApplianceparts.com today,
24 hours a day or by phone at 877.959.8688 during
normal business hours. In Canada, visit your local
GE Appliances parts distributor or call 800.661.1616
GEAppliances.ca/en/products/parts-filters-accessories.
or
2249-3000206 Rev 3
Installation Instructions
ELECTRICAL CONNECTION
INFORMATION FOR ELECTRIC DRYERS
For electrical connections using a
power cord:
NOTE: If your dryer circuit is on a circuit protected by a
GFCI breaker, then 3-wire installation is not permitted.
House wiring and dryer must be configured for 4-wire.
WARNING
Use a new UL-listed 240V 30 amp dryer power supply
cord with closed ring terminals or spade terminals with
upturned ends.
Use a UL-listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining two supply wires to remaining two
terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical shock.
- Fire Hazard
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer: This dryer
must be grounded. In the event of a malfunction or
breakdown, grounding will reduce the risk of electric
shock by providing a path of least resistance for
electric current. This dryer uses a cord having an
equipment-grounding conductor and a grounding
plug. The plug must be plugged into an appropriate
outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
WARNING
result in a risk of electric shock. Check with a qualified
electrician, or service representative or personnel, if
you are in doubt as to whether the appliance is properly
grounded. DO NOT modify the plug on the power supply
cord. If it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
WARNING
Improper connection of the
equipment-grounding conductor can
- Electrical Shock Hazard
ELECTRICAL CONNECTION
INFORMATION FOR ELECTRIC
DRYERS
For direct wire connections:
WARNING
Use 10 gauge copper wire.
Use a UL-listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining two supply wires to remaining two
terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical shock.
- Fire Hazard
GROUNDING INSTRUCTIONS
For a permanently connected dryer: This dryer
must be connected to a grounded metal, permanent
wiring system, or an equipment-grounding conductor
must be run with the circuit conductors and
connected to the equipment-grounding terminal on
the appliance.
WARNING
result in a risk of electric shock. Check with a qualified
electrician, or service representative or personnel, if
you are in doubt as to whether the appliance is properly
grounded.
SAVE THESE INSTRUCTIONS
WARNING
TO PREVENT ELECTRIC SHOCK, DISCONNECT
POWER BEFORE SERVICING.
This dryer should be connected to an individual branch
circuit with 10 gauge copper wire minimum through a
30 amp fuse or circuit breaker. DO NOT fuse neutral.
Use copper conductors only.
Improper connection of the
equipment-grounding conductor can
- Electrical Shock Hazard
TO PREVENT ELECTRIC SHOCK, DISCONNECT
POWER BEFORE SERVICING.
This dryer should be connected to an individual branch
circuit with 10 gauge copper wire minimum through a
30 amp fuse or circuit breaker. DO NOT fuse neutral.
Use copper conductors only.
49-3000206 Rev 323
Installation Instructions
CONNECTING AN ELECTRIC DRYER (cont.)
CONNECTING DRYER USING
4-WIRE CONNECTION (MUST
BE USED FOR MOBILE HOME
INSTALLATION)
NOTE: Since January 1, 1996, the National Electrical
Code requires that new constructions use a 4-wire
connection to an electric dryer. A 4-wire cord must
also be used where local codes do not permit grounding
through the neutral. 3-wire connection is NOT for use
on new construction.
Black
Dryer’s White Strap
Looped to Neutral (N)
Green wire from
power cord
Cover
4 #10 AWG minimum copper conductors or 120/240V 30A
power supply cord kit marked for use with dryers and provided
with closed loop or spade terminals with upturned ends (not
supplied).
1. Turn off the circuit breaker(s) (30 amp) or remove
the dryer’s circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall
receptacle.
3. Remove the power cord cover located at the lower
back.
4. Remove green ground screw and retain for use
in Step 7. Leave one end of the short white strap
loose until Step 6. Remove center screw (marked
N) in terminal block.
5. Place the UL-recognized metal strain relief clamp
to power cord entry hole. Bring power cord through
strain relief clamp.
6. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of the
terminal block (marked L1 and L2).
B. Connect the neutral (white) line and the loose
end of the short white strap to the center of the
terminal block (marked N).
7. Attach ground wire of power cord with the green
ground screw (hole to left of strain relief clamp).
Tighten all terminal block screws (3) securely.
8. Properly secure power cord to strain relief clamp.
9. Reinstall the cover.
or Red
Wire
White
Wire
L1 N L2
NEVER LEAVE THE COVER OFF OF THE
TERMINAL BLOCK.
Black
or Red
Wire
Metal Strain
Relief
Clamp UL
CONNECTING DRYER USING
3-WIRE CONNECTION
NOTE: If your dryer circuit is on a circuit protected by a
GFCI breaker, then 3-wire installation is not permitted.
House wiring and dryer must be configured for 4-wire.
If required, by local code, install external ground (not
provided) to grounded metal, cold water pipe, or other
established ground determined by a qualified electrician.
Black
or Red
Wire
Ground
White Strap
Cover
3 #10 AWG minimum copper conductors or 120/240V 30A
power supply cord kit marked for use with dryers and provided
with closed loop or spade terminals with upturned ends (not
supplied).
3-wire Connection
Not for use in Canada.
DO NOT use for Mobile Home Installations.
NOT for use on new construction.
NOT for use on recreational vehicles.
NOT for use in areas where local codes prohibit
grounding through the neutral conduction.
1. Turn off the circuit breaker(s) (30 amp) or remove
the dryer’s circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall
receptacle.
3. Remove the power cord cover located at the lower
back.
4. Place the UL-recognized metal strain relief clamp
to power cord entry hole. Bring power cord through
strain relief clamp.
5. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of
the terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
6. Be sure ground white strap is connected to green
ground screw on cabinet rear. Tighten all terminal
block screws (3) securely.
7. Properly secure power cord to strain relief clamp.
8. Reinstall the cover.
White
Wire
L1 N L2
NEVER LEAVE THE COVER OFF OF THE
TERMINAL BLOCK.
Black
or Red
Wire
Metal Strain
Relief
Clamp UL
2449-3000206 Rev 3
Installation Instructions
Ŷ
Ŷ
Ŷ
Ŷ
EXHAUSTING THE DRYER
WARNING
This dryer MUST be vented to the outdoors.
Use only 4” (10.2 cm) rigid metal ducting for
the home exhaust duct.
Use only 4" (10.2 cm) rigid metal, UL-listed
flexible metal, or UL-listed metal foil dryer
transition duct to connect the dryer to the
home exhaust.
DO NOT use any plastic to vent the dryer,
this includes the home exhaust duct, dryer
transition duct, or within the dryer.
DO NOT use flexible metal or metal foil ducting
for a home exhaust duct or within the dryer.
DO NOT exhaust into a chimney, kitchen
exhaust, gas vent, wall, ceiling, attic, crawl
space, or concealed space of a building.
DO NOT install a screen in or over the exhaust
duct.
DO NOT install a booster fan in the exhaust duct.
DO NOT use duct longer than specified in the
exhaust length table.
Failure to follow these instructions can result in
death or fire.
TOOLS AND MATERIALS YOU WILL
NEED TO INSTALL EXHAUST DUCT
Ŷ
1/4" (6.4 mm) Socket &
Nut Driver
Ŷ
Duct tape or
duct clamp
PARTS AVAILABLE FROM
GEAPPLIANCEPARTS.COM OR
LOCAL SERVICE ORGANIZATIONS
• For best drying performance, a rigid metal transition
duct is recommended.
• Rigid metal transition ducts reduce the risk of
crushing and kinking.
UL-LISTED FLEXIBLE METAL CLOTHES
DRYER TRANSITION DUCT
• If rigid metal cannot be used, then UL-listed flexible
metal clothes dryer transition duct (GE Appliances
part – PM08X10085) can be used.
• Never install transition duct in walls, ceilings, floors
or other enclosed spaces.
• Total length of transition duct should not exceed 8’
(2.4 m).
• For many applications, installing elbows at both
the dryer and the wall is highly recommended (see
illustrations in next section). Elbows allow the dryer
to sit close to the wall without kinking and/or crushing
the transition duct, maximizing drying performance.
• Avoid resting the duct on sharp objects.
UL-LISTED FLEXIBLE METAL (FOIL-TYPE)
TRANSITION DUCT
• In special installations, it may be necessary to
connect the dryer to the home exhaust vent
using flexible metal (foil-type) transition duct. UL–
LISTED universal flexible dryer transition duct
(GE Appliances parts – PM8X73 or WX8X73)
may be used ONLY in installations where rigid
metal or flexible metal transition ducting cannot
be used AND where a 4” (10.2 cm) diameter can
be maintained throughout the entire length of the
transition duct.
• In Canada and the United States, only transition
ducts that comply with “UL 2158A STANDARD FOR CLOTHES DRYER TRANSITION DUCT”
shall be used.
• Avoid resting the duct on sharp objects.
• For best drying performance:
1. Slide one end of the duct over the clothes
dryer outlet pipe.
2. Secure the duct with a clamp.
3. With the dryer in its permanent position,
extend the duct to its full length. Allow 2” (5.08
cm) of duct to overlap the exhaust pipe. Cut
off and remove excess duct. Keep the duct as
straight as possible for maximum airflow.
4. Secure the duct to the exhaust pipe with the
other clamp.
49-3000206 Rev 325
Installation Instructions
EXHAUSTING THE DRYER (cont.)
• DO cut duct as short
as possible and
install straight into
wall.
• DO NOT bend
or collapse
ducting.
Use elbows
if turns are
necessary.
• DO NOT use
excessive
exhaust
length. Cut
duct as short
as possible.
EXHAUST LENGTH
Using exhaust longer than specified length will:
• Increase the drying times and the energy cost.
• Reduce the dryer life.
• Accumulate lint, creating a potential fire hazard.
The correct exhaust installation is YOUR
RESPONSIBILITY.
Problems due to incorrect installation are not
covered by the warranty.
The MAXIMUM ALLOWABLE length of the exhaust
system depends upon the type of duct, number of turns,
the type of exhaust hood (wall cap) and all conditions
noted on the chart.
• Internal elbows added for side or bottom vent
conversions must be included in the total elbow count.
• Any elbow greater than 45° should be treated as a 90°
elbow; one elbow of 45° or less may be ignored.
• Two 45° elbows will be treated like one 90° elbow.
• For the side exhaust installations, add one 90° elbow to
the chart.
• For every additional 90° elbow, reduce the allowable
vent system length by 10 feet (3 m).
• When calculating the total vent system length, you
must add all the straight portions and elbows of the
system (including the transition duct).
•DO use elbows
when turns are
necessary.
Elbows
• DO NOT
set dryer
on duct
installations
4" DIA.
EXHAUST
LENGTH
FOR
NORMAL
• DO NOT
crush duct
against
the wall
4" DIA.
.
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
4" DIA.
Use only for short run
VENT
MODELS
No. of 90° ElbowsRigid MetalRigid Metal
090 Feet (27.4 m)60 Feet (18.3 m)
160 Feet (18.3 m)45 Feet (13.7 m)
245 Feet (13.7 m)35 Feet (10.7 m)
335 Feet (10.7 m)25 Feet (7.6 m)
425 Feet (7.6 m)15 Feet (4.6 m)
EXHAUST
LENGTH
FOR
LONG
4"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
4" DIA.
4" DIA.
Use only for short run
installations
4" DIA.
2-1/2"
VENT
MODELS
No. of 90° ElbowsRigid MetalRigid Metal
0200 Feet (61 m)175 Feet (53.3 m)
1185 Feet (56.4 m)165 Feet (50.3 m)
2175 Feet (53.3 m)155 Feet (47.2 m)
3165 Feet (50.3 m)145 Feet (44.2 m)
4155 Feet (47.2 m)135 Feet (41.1 m)
5145 Feet (44.2 m)125 Feet (38.1 m)
4"
2-1/2"
.
2649-3000206 Rev 3
Installation Instructions
EXHAUSTING THE DRYER (cont.)
EXHAUST SYSTEM CHECKLIST
HOOD OR WALL CAP
• Terminate in a manner to prevent back drafts or entry of
birds or other wildlife.
• Termination should present minimal resistance to
the exhaust airflow and should require little or no
maintenance to prevent clogging.
• Wall caps must be installed at least 12” (30.5 cm)
above ground level or any other obstruction with the
opening pointed down.
SEPARATION OF TURNS
• For best performance, separate all turns by at least
4 ft. (1.2 m) of straight duct, including distance
between last turn and dampened exhaust hood
(wall cap).
SEALING OF JOINTS
• All joints should be tight to avoid leaks. The male end
of each section of duct must point away from the dryer.
• Duct joints should be made air- and moisture-tight
by wrapping the overlapped joints with duct tape or
aluminum tape.
• Do not assemble ductwork with any fasteners that
extend into the duct. These fasteners can accumulate
lint, creating a potential fire hazard.
• Horizontal runs should slope down towards the
outdoors 1/4” (6.4 mm) per foot.
• Provide an access for inspection and cleaning of
the exhaust system, especially at turns and joints.
Exhaust system shall be inspected and cleaned at
least once a year.
INSULATION
• Ductwork that runs through an unheated area or is
near air conditioning should be insulated to reduce
condensation and lint build-up.
STANDARD REAR EXHAUST
We recommend that you install your dryer before
installing your washer. This will permit direct
access for easier exhaust connection.
Slide the end of the exhaust duct on the back of the
dryer and secure with duct tape or a hose clamp.
Duct
NOTE: We strongly recommend using rigid metal
exhaust duct. However, if flexible ducting is used it
must be UL-Listed metal, not plastic.
• For straight line installation, connect the dryer
exhaust to the external exhaust hood using duct
tape or clamp.
Wall Side
Duct Tape
Dryer
Side
RECOMMENDED CONFIGURATION
TO MINIMIZE EXHAUST BLOCKAGE
Using duct elbows will prevent duct kinking and
collapsing.
BEFORE YOU BEGIN
• Remove and discard existing plastic or metal foil
duct and replace with UL-listed duct.
• Remove any lint from the wall exhaust opening.
Wall
Internal
Duct
Opening
Check that exhaust
hood damper
opens and closes
freely.
49-3000206 Rev 327
Wall
Transition
Ducting
Installation Instructions
EXHAUSTING THE DRYER (cont.)
SIDE VENTING
WARNING
Disconnect dryer from electrical supply.
Wear gloves and arm guards.
Close the back opening with the access
panel included in kit GFA28DSVN.
Failure to do so may result in fire, electrical
shock or lacerations.
• Remove the 4 screws that secure the access panel
and save. Remove the access panel.
Remove
4 screws
and save
• Detach and remove the right or left side knockout
as desired. Remove the screw that secures the
dryer exhaust duct and save. Pull the exhaust duct
out of the dryer.
Right
knockout
- Fire Hazard
Access Panel
SIDE VENTING (cont.)
• Insert and connect the elbow/exhaust duct assembly
to the blower housing and orient the elbow for either
left or right venting.
Left Venting
Right Venting
• Locate the bracket from the kit.
• Remove the adhesive liner from the bottom of the
bracket and position it behind the elbow duct tab.
• Press down firmly to secure the bracket to the bottom
of the dryer.
Exhaust Duct
Remove screw and save
• Locate the 12-1/2” (31.5 cm) exhaust duct and
elbow duct from the kit and assemble together.
Apply duct tape around the joint to eliminate leaks
between ducts.
12-1/2" (31.5 cm)
Left Knockout
Elbow Duct Tab
Bracket
Saved Screw
• Using one of the screws from earlier, secure the
elbow duct tab to the bracket.
2849-3000206 Rev 3
Installation Instructions
EXHAUSTING THE DRYER (cont.)
SIDE VENTING (cont.)
For LEFT venting:
• Locate the 15-1/2” (39.4 cm) exhaust duct from the kit.
• Insert exhaust duct through knockout opening on
the LEFT side of dryer.
• Assemble exhaust duct to elbow duct.
• Wrap the joint with duct tape to avoid air leaks.
Left
Venting
For RIGHT venting:
• Locate the 9-1/2” (24.2 cm) exhaust duct from the kit.
• Insert exhaust duct through knockout opening on
the RIGHT side of dryer.
• Assemble exhaust duct to elbow duct.
• Wrap the joint with duct tape to avoid air leaks.
Right
Venting
BOTTOM VENTING
Dryer Exhaust to the bottom of cabinet for Gas
and Electric models WITHOUT Built-In Pedestal™.
WARNING
Disconnect dryer from electrical supply.
Wear gloves and arm guards.
Close the back opening with the access
panel included in kit GFA28DSVN.
Failure to do so may result in fire, electrical
shock or lacerations.
• Remove the 4 screws that secure the access panel
and save. Remove the access panel.
Remove
4 screws
and save
• Remove the screw that secures the dryer exhaust
duct and save. Pull the exhaust duct out of the dryer.
- Fire Hazard
Access Panel
• Install the new access panel from the kit.
• Secure access panel with 4 screws saved from
earlier.
NEVER LEAVE THE BACK OPENING WITHOUT
THE ACCESS PANEL.
Exhaust Duct
Remove screw and save
• Detach and remove the bottom knockout.
Bottom Knockout
49-3000206 Rev 329
Installation Instructions
EXHAUSTING THE DRYER (cont.)
BOTTOM VENTING (cont.)BOTTOM VENTING (cont.)
• Locate the 12-1/2” (31.5 cm) exhaust duct and
elbow duct from the kit and assemble together.
Apply duct tape around the joint to eliminate leaks
between ducts.
12-1/2” (31.5 cm)
• Install the new access panel from the kit.
• Secure access panel with 4 screws saved from
earlier.
• Insert and connect the elbow/exhaust duct
assembly to the blower housing and insert the
elbow through the bottom knockout.
NEVER LEAVE THE BACK OPENING WITHOUT
THE ACCESS PANEL.
3049-3000206 Rev 3