Installation Preparation
PREPARE ELECTRICAL WIRING
FORPERSONALSAFETVI " ' Receptacle : ",
_Ji Remove house fuse or open circuit breaker ' Location --r-k ",,
before beginning installation. Donot use
an extension cord or adapter plug with
this appliance, 8''ill ::
I ,:i
!
Electrical Requirements
• This appliance must be supplied with 120V, 60Hz.. and
connected to on individual properlg grounded branch circuit.
protected bg a 15 or 20 ampere circuit breaker or time delay
fuse.
oWiring must be 2 wire with ground and rated for 75°C {176%}.
• If the electrical supply does not meet the above
requirements, call a licensed electrician before proceeding.
8. /
:::::\ ; ! Hole(Max,} \ t]---
_,-F_ 3'from
! _: :':::: Ca,b',inet
/Receptacle from Wakkx_x_k
V Location
Area Ground-_' i
Figure E Black-" VVhite
Grounding Instructions-Cable Direct
This appliance must be connected to a grounded metal,
permanent wiring sgstem, or an equipment grounding
conductor must be run with the circuit conductors and be
connected to the equipment grounding terminal or lead on the
appliance.
Grounding Instructions-Power Cord Models
This appliance must be grounded. In tile event of o malfunction
or breakdown, grounding will reduce the risk of electric shock
bg providing a path of least resistance for electric current.
This appliance is equipped with o cord having an equipment
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is installed and
grounded in accordance with at! local codes end ordinances.
The improper connection of the equipment
grounding conductor can result in a risk
of electric shock. Check with a qualified
electrician or service representative if gou
are in doubt that the appliance is propertg
grounded.
For models equipped with power cord: Do not modifg the plug
provided with the appliance; if it will not fit the outlet hove a
proper outlet installed by a qualified technician.
Cabinet Preparation and Wire Routing
• The wiring meg enter the opening from efther side, rear or the
floor within the shaded area.
° Cut o 1-t/2" maximum diameter hole to admit the electrical
cable. Cable direct connections meg pass through the same
hole as the drain hose and hot water line, if convenient. If
cabinet wal! is metal, the hole edge must be €overed With
a bushing.
Note: Power cords with plug must pass through a separate
hole.
Electrical Connection to Dishwasher
Electrical connection is on the right front of dishwasher.
• For cable direct connections the cable must be routed as
shown in Figure E Cable must extend a minimum of 24" from
the rear wall.
° For power cord connections, install a 3-prong grounding tgpe
receptacle in the sink cabinet rear wall. 6" min, or !8" max.
from the opening, 6" to 18" above the floor.
..... --iii //