GE PB3-POS-RP User Manual

PB3-POS-RP ProBridge
User Manual
PB3-POS-RP ProBridge
2
User Manual
Copyright Copyright © 2006, GE Security, Inc. All rights reserved.
Document number/0150-0231J. (July 2006)
Disclaimer THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT
Trademarks and patents
Software
license
agreement
Intended use Use this product only for the purpose it was designed for; refer to the data
compliance
Regulatory
NOTICE. GE ASSUMES NO RESPONSIBILITY FOR INACCURACIES OR OMISSIONS AND SPECIFICALLY DISCLAIMS ANY LIABILITIES, LOSSES, OR RISKS, PERSONAL OR OTHERWISE, INCURRED AS A CONSEQUENCE, DIRECTLY OR INDIRECTLY, OF THE USE OR APPLICATION OF ANY OF THE CONTENTS OF THIS DOCUMENT. FOR THE LATEST DOCUMENTATION, CONTACT YOUR LOCAL SUPPLIER OR VISIT US ONLINE AT
This publication may contain examples of screen captures and reports used in daily operations. Examples may include fictitious names of individuals and companies. Any similarity to names and addresses of actual businesses or persons is entirely coincidental.
GE and the GE monogram are registered trademarks of General Electric. The PB3-POS-RP ProBridge product and logo are registered trademarks of GE Security.
Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products.
GE software supplied with GE products is proprietary and furnished under license and can be used or copied only in accordance with the license terms.
THE ENCLOSED PROGRAM IS FURNISHED SUBJECT TO THE TERMS AND CONDITIONS OF THIS AGREEMENT. RETENTION OF THE PROGRAM FOR MORE THAN 30 DAYS, OPENING OF THE SEALED WRAPPER, IF ANY, SURROUNDING THE PROGRAM, OR USE OF THE PROGRAM IN ANY MANNER WILL BE CONSIDERED ACCEPTANCE OF THE AGREEMENT TERMS. IF THESE TERMS ARE NOT ACCEPTABLE, RETURN THE UNUSED PROGRAM AND ANY ACCOMPANYING DOCUMENTATION TO GE FOR A FULL REFUND OF THE LICENSE FEE PAID. (FOR INFORMATION REGARDING THE RETURN OF PROGRAMS ENCODED OR INCORPORATED WITHIN EQUIPMENT, CONTACT THE NEAREST GE SALES OFFICE.)
sheet and user documentation. For the latest product information, contact your local supplier or visit us online at
FCC
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
You are cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Operation of this equipment in a residential area may cause interference, in which case the user is required to take all measures that are necessary, at the user's expense, to correct the interference
WWW.GESECURITY.COM.
www.gesecurity.com.
TABLE OF CONTENTS
BEFORE YOU BEGIN....................................................5
INTRODUCTION............................................................7
PB3-POS-RP OVERVIEW.............................................................7
OMPATIBILITY.............................................................................8
C
DDITIONAL EQUIPMENT ...............................................................8
A
ISCLAIMER .................................................................................8
D
PB3 SYSTEM COMPONENTS........................................9
INSTALLATION ENVIRONMENT......................................................10
3
OWER.......................................................................................11
P
INSTALLATION...........................................................13
PB3 COMPONENTS.....................................................................13
YPICAL SYSTEM LAYOUT ...........................................................14
T
REQUIRED DIP SWITCH INFORMATION.........................15
DEFAULT (FACTORY) DIPSWITCH SETTINGS.................................15
ETAILED INSTALLATION STEPS ..................................................16
D
PB3-POS-RP ProBridge
4
User Manual
VERIFY OPERATION.................................................................... 17
DIP SWITCH SETTINGS ..............................................19
SW1 SETTINGS ..........................................................................19
SW2 S
SW3 S
SW4 S
T
ETTINGS ..........................................................................22
ETTINGS ..........................................................................24
ETTINGS ..........................................................................26
ROUBLESHOOTING ....................................................................27
HYPERTERMINAL SETUP............................................28
EQUIPMENT REQUIRED................................................................28
ETUP........................................................................................28
S
PB3 SPECIFICATIONS ...............................................40
CABLE SPECIFICATIONS..............................................................41
CONTACTING TECHNICAL SUPPORT.............................48
ONLINE PUBLICATION LIBRARY ....................................................48
Before You Begin
Read these instructions before installing or operating this product.
Note: This installation should be made by a qualified service person and should conform to local codes.
This manual provides installation and operation information. To use this document, you must have the following minimum qualifications:
A basic knowledge of CCTV systems and components
A basic knowledge of electrical wiring and low-voltage
electrical hookups
Use this product only for the purpose for which it was designed.
Customer Support
For assistance in installing, operating, maintaining, and troubleshooting this product, refer to this document and any other documentation provided. If you still have questions, contact Technical Support:
5
GE Security Call: 888-437-3287
Note: You should be at the equipment, ready with details before calling Technical
Support.
Conventions Used in this Manual Boldface or button icons highlight command entries. The
following WARNING, CAUTION, and Note statements identify potential hazards:
PB3-POS-RP ProBridge
6
User Manual
* WARNING:
Improper use of this equipment can cause severe bodily injury or equipment damage.
** CAUTION:
Improper use of this equipment can cause equipment damage.
Note: Notes contain important information about a product or procedure. * This symbol indicates electrical warnings and cautions.
** This symbol indicates general warnings and cautions.
Introduction
This manual provides all the information necessary to properly install this product.
** CAUTION:
Your system’s layout, camera assignment, PB3 termination, and serial device model should all be selected before starting the installation.
PB3-POS-RP Overview
The GE PB3-POS-RP (PB3) is a specific model of ProBridge that interfaces the DVMRe family of digital video multiplexer/recorders to retail point-of-sale (POS) devices often identified as electronic cash registers (ECRs) and some ATM’s.
One PB3 is required per device. Where multiple devices are connected to a single DVMRe unit, the individual PB3’s are interconnected through its built-in RS485 network.
7
A list of the supported can be found in the DIP switch settings section on page 24.
serial devices associated with the devices
PB3-POS-RP ProBridge
8
User Manual
Compatibility
The PB3 is compatible with the following GE DVMRe products:
DVMRe Type Software Version PPC Version
DVMRe-CD/CS V 3.07 (and above) V 3.07 (and above) DVMRe-eZ V 3.20 (and above) V 3.14 (and above) DVMRe-CT and DVMRe-CT II DVMRe-eZT
(Triplex) StoreSafe and
StoreSafe Pro II To verify the software version in your DVMRe, note the display
which identifies the version when the unit boots-up or you can click the About box in the Main Menu.
V 4.0 (and above) N/A
V 4.03 (and above) N/A
V 4.06 (and above) N/A
Additional Equipment
The installer will need to provide suitable length RS485 cable terminated with RJ-45 connectors on installations requiring multiple PB3 units that are interconnected via the unit’s built-in RS485 network.
Disclaimer
The GE ProBridge components identified within this document provide means of capturing transaction text/data for use by the DVMRe family of digital video recording/transmission products. The ProBridge components translate the data into a usable format by the DVMRe and permits associating transaction data
with specific cameras. GE assumes no responsibility for the amount and type of information available, the operation, non­operation or erroneous operation of the customer provided equipment that interfaces with the ProBridge.
PB3 System Components
You should find the following PB3 system components when the product is unboxed.
9
Figure 1-1. PB3-POS-RP Box Contents.
PB3-POS-RP ProBridge
10
User Manual
PB3-POS-RP ProBridge includes:
(1) PB3-POS-RP ProBridge unit.
(1) P/N 4310-0034B: RJ45 to RJ45 cable. Connects the
PB3 to RS485 Network. This cable is 6’ in length.
(1) P/N 4310-0068A: serial device Interconnect Cable. This cable is 14” in length.
(1) P/N 4310-0047B: RJ45 to DB9F cable. Connects the PB3 to the DVMRe. This cable is 6’ in length.
(1) P/N 4310-0069A: serial device to PB3 Cable. This cable is 6’ in length.
(1) P/N 0900-0176: Triport Cable. This cable is 6’ in length.
(1) P/N 4010-0007: 12VDC 120VAC Power Supply or (1) P/N 4010-0008: 12VDC 220VAC Power Supply.
(1) P/N 0150-0231C: PB3-POS-RP User Manual.
Installation Environment
Power: Ensure that the installation site’s AC power is stable and within the rated voltage of the external power supply. If the site’s AC power is likely to have spikes or dips, use power line conditioning or an Uninterruptible Power Supply.
Temperature: Observe the unit’s ambient temperature specifications when choosing a location for the unit. Extremes of heat or cold beyond the specified operating temperature limits may cause the unit to fail. Do not install this unit on top of other hot equipment.
Moisture: Do not expose the unit to rain or moisture. Moisture can damage internal components. Do not install this unit near sources of water.
RS232 Limitations: Cable length between the POS device and the PB3 is limited to 50’. Cable length between the PB3 unit and the DVMRe is also limited to 50’. If the supplied cables are replaced by custom made cables to address distances between components, ensure the cable is manufactured to ANSI standards for RS232 communication.
RS485 Limitations: If multiple PB3 units are connected to a single DVMRe unit, the distance between the first and last PB3 unit is limited to 3,000 feet (RS485 communication standards).
Power
The PB3 is furnished with a power supply (110 or 240 VAC). Do not use any other power supply with this product. The manufacturer accepts no responsibility for damage caused by the use of any other power supply.
11
Make sure installation is complete and all connections are made before applying power to the unit.
PB3-POS-RP ProBridge
12
User Manual
4310-0007 120VAC Power Supply
Power Supply Input
Voltage: 120 VAC Tolerance: ±10% Frequency: 60 Hz
Voltage: 12 VDC Current: 110 mA Power: 1.3 Watts Connector: 2.1mm female barrel. Center Positive
Power Supply Output
4310-0008 220VAC Power Supply
Power Supply Input
Voltage: 220 Volt AC Tolerance: ±10% Frequency: 50 Hz
Voltage: 12 Volt DC Current: 110mA Power: 1.3 Watts Connector: 2.1mm female barrel. Center Positive
Power Supply Output
Installation
Before installation please familiarize yourself with the PB3 and its typical system layout.
PB3 Components
13
Figure 2-1. ProBridge Components.
PB3-POS-RP ProBridge
*
14
User Manual
Typical System Layout
Monitor
RS232/2
Port
DVMRe Triplex
4310-0034B
RJ45 to RJ45
Cable
Port 1
Port 2
Cable
Receipt Printer
*
Cable
Receipt Printer
Port 0
*
Electronic Cash Register
Electronic Cash Register
Camera
Camera
CBR-PB3-RP
ProBridge
4310-0069A
Printer to PB3
4320-0068A
Receipt Printer
Cable
2nd
CBR-PB3-RP
ProBridge
4310-0069A
Printer to PB3
4320-0068A
Receipt Printer
Cable
Power Connections not show for clarity.
Figure 2-2. Typical System Layout.
RS485 Cable
(Supplied by Installer)
** IMPORTANT:
Your system’s layout, camera assignment, PB3 termination, and serial device model should all be selected before starting the installation.
Required Dip Switch Information
SW1 Dipswitch 1-4 Special Functions (See Section
3) Dipswitch 5-8 Camera Assignment* SW2 Dipswitch 1 Reserved Dipswitch 2-4 Baud Rate Dipswitch 5-8 Protocol
SW3 Dipswitch 1-8 serial device Device Select* SW4 Dipswitch 3 ProBridge Termination*
*These settings should be set before beginning the installation.
Default (Factory) Dipswitch Settings
SW1 SW2 SW3 SW4
1 Up 1 Down 1 Down 1 Up 2 Up 2 Down 2 Down 2 Up 3 Up 3 Down 3 Down 3 Up 4 Up 4 Down 4 Down 4 Up 5 Up 5 Down 5 Down 5 Up 6 Up 6 Down 6 Down 6 Up 7 Up 7 Down 7 Down 7 Down 8 Up 8 Down 8 Down 8 Up
15
Loading...
+ 33 hidden pages