These instructions do not purport to cover all details or variations in equipment nor to provide every
possible contingency to be met during installation, operation, and maintenance. If further information is
desired or if particular problems arise that are not covered sufficiently for the purchaser’s purpose, the
matter should be referred to GE Security.
This document contains proprietary information of GE Security and is furnished to its customer solely to
assist that customer in the installation, testing, operations, and/or maintenance of the equipment
described. This document shall not be reproduced in whole or in part nor shall its contents be disclosed to
any third party without the written approval of GE Security.
Please refer to the current GE Security product catalog for detailed warranty information.
Main
800-727-2339 Technical Support 888-437-3287
Outside the US 903-845-6941 Sales & Literature 800-547-2556
Main Fax 903-845-6811
Web: www.gesecurity.com
ORDERING INFORMATION
PART # DESCRIPTION
NX-8 KIT Includes NX-8 Control, NX-108E LED Keypad, & 16.5V 40VA Transformer
NX-8 NX-8 Control Only
NX-108E 8 Zone LED Keypad
NX-116E 16 Zone LED Keypad
NX-124E 24 Zone LED Keypad
NX-148E Alphanumeric LCD Keypad
NX-200 ** Zone Doubling Kit (Includes 100 3.74k and 100 6.98k resistors)
NX-216E 16 Zone Expander Module
NX-320E Smart Power Supply and Buss Extender
NX-408E # 8 Zone Wireless Expansion Module (UL LISTED PART #60-904)
NX-416E # 16 Zone Wireless Expansion Module (UL LISTED PART #60-904)
NX-448E # 48 Zone Wireless Expansion Module (UL LISTED PART #60-904)
NX-507E Seven Relay Module
NX-508E Eight Output Module
NX-534E ** Two-Way Listen-In Module
NX-540E ** "Operator" Telephone Interface Module
NX-591E ** Cellemetry Interface
NX-1192E 192 Zone LCD Keypad
NX-1208E 8 Zone LED Keypad
NX-1248E 48 Zone LCD Keypad
NX-1308E 8 Zone LED Door Design Keypad
NX-1316E 16 Zone LED Door Design Keypad
NX-1324E 24 Zone LED Door Design Keypad
NX-1448E 48 Zone Fixed Language Icon Keypad
** These products have not been tested and approved by Underwriters Laboratories, Inc.
# These wireless devices are only UL listed for residential applications.
2
NX-8 Control
Page 3
Table of Contents
GENERAL DESCRIPTION....................................................................................................................................... 4
The NetworX NX-8 represents a new approach to security systems design. Drawing on our experience in the world
market as the largest exporter of USA manufactured controls, we have developed the most flexible, durable, and userfriendly control ever seen in our industry. Featuring sophisticated software that allows up to 99 users to interface with
48 zones, 8 partitions, and a host of integrated fire, access, verification, and input/output modules, all reported with the
most comprehensive and fast SIA and Contact ID formats. The NetworX design allows a fully loaded system to be
housed in one single metal enclosure, establishing for the first time, a logical solution and design response to modular
systems. Up to 32 modules can be added to expand the capabilities of the NX-8.
Board Installation
Inside the can, several 2-holed insertion points have been constructed. This
allows for either vertical or horizontal placement of the modules. Notice that
each insertion point has two sizes of holes -a larger hole and a smaller hole.
Diagram 1
PC board will be seated. The end with the half-moon protrusion fits into the
larger hole. The smaller hole is for the screw.
Diagram 2
grooved edge downward. The half-moon protrusion will be in the large hole. It
does not require force. Insert one of the provided screw into the smaller hole
(from inside the can) to secure it in place. A screwdriver should reach through
the notch that runs the length of the guide to tighten the screw. The second
PBC guide should be positioned opposite the first (grooved edge up) and
placed in the lower insertion point, using the same procedures described
above. Once mounted, screw it in securely.
Diagram 3
K
: The black plastic PCB guides are grooved on one edge where the
: Place the first black plastic PCB guide in the top insertion point,
: The PC Board should slide freely in the grooves of both guides.
IMPORTANT!
1. If separate power supplies are necessary to accommodate additional devices, safety
standards require that each power supply be prominently marked with adequate instructions
for removing all power from the unit.
2. Dispose of used batteries according to the manufacturer’s instructions and/or local
government authorities.
3. Installation personnel should thoroughly read and understand the installation instructions
and the users manuals for the panel and all the accessories to be included with the system
before attempting to install a security system.
WARNING!
Replace only with Panasonic #LC12V4BP or Yuasa #NP4-12 battery. Observe polarity when
installing a new battery. Installing the battery backwards may cause damage to the panel. There
is a risk of explosion if the battery is replaced with an incorrect type.
NOTE
Electrical codes will vary depending upon the country and city where the system is installed. It is
the installer’s responsibility to ensure that the electrical installation is safe and conforms to all
applicable codes, laws, or regulations. Only qualified persons should connect this device to the
mains supply.
4
NX-8 Control
Page 5
FEATURE DEFINITIONS
- If enabled, the NX-8 will wait the programmed number of seconds in location 40 prior to sending an alarm.
Abort
During this delay time, the "Cancel" LED will flash. To abort the report, type in a code and press the [Cancel] key. The
LED will extinguish. If the report is not aborted within the allotted time, the LED will extinguish when the report is sent.
ADialer Delay@ must be enabled in the ACharacteristic Select@ of locations 110-149. (See locations 40 and 110-149,
pages 24 and 35)
AC Fail / Low Battery Report/Warning
- The NX-8 can be programmed to report AC failure and/or Low Battery
conditions to the central station. It can also be programmed to sound the keypad immediately upon detection of the
condition. The AC failure report/warning can be delayed.(See locations 37 and 39, page 23)
AC Power / Low Battery Sounder Alert
- If enabled, the NX-8 will beep the keypad sounder upon arming or
disarming if the AC power is missing or a low battery has been detected. (See location 23, page 19)
Arm / Disarm Codes
- The NX-8 can have 99 four-digit codes or 66 six-digit codes to arm/disarm the control. All
codes must have the same number of digits. The factory d efault for Use r #1 is [1]-[2]-[3]-[4] when using a 4-digit code,
or [1]-[2]-[3]-[4]-[5]-[6] for a 6-digit code. This code can then be used to enter the new arm/disarm codes. (See
location 41, page 24)
Automatic Arming
- If programmed, the NX-8 will Auto Arm at a specified time. At this time, the keypad will beep for
50 seconds before the panel arms. The arming process will be stopped if a code is entered on the keypad. The NX-8
will attempt to arm after every 45 minutes of inactivity until the next “opening” time (loc. 52), or until t he system is
armed. The 45-minute timer will be extended when there is activity in the building causing the "Ready" LED to turn off
and on. If closing reports are sent, the user code will be 97. (See locations 23, and 52-55, pages 19 and 27)NOTE:
For UL installations, this feature shall be disabled.
Auto Cancel / Abort
- If enabled, the Cancel and/or Abort features will be automatic (pressing the [Cancel] button is
not required). The Cancel and Abort features, in locations 23 and 40 respectively, must be enabled to permit this Auto
feature to work. For proper operation of these features, ADialer Delay@ must be enabled in the ACharacteristic Select@
of locations 110-149 Zone Types. (See location 41, page 24)
Automatic Bypass / Instant Arming
- When enabled, the control panel can automatically bypass interior follower
zones if an exit is not detected during the exit delay time. Entry delay zones can also be made instant.
(See location 23, segments 1 and 3, page 19)
Auto Test
- This feature will cause the panel to call the central station to report a communicator test at a specifie d
interval. (See location 51, page 27)
Auxiliary Outputs
- The NX-8 has four programmable outputs that can be used to activate relays, LED=s, etc. (See
the terminal description on page 56 and locations 45-50, page 25)
Auxiliary Power Overcurrent
- The NX-8 will illuminate the "Service" LED on the keypad whenever too much current
is drawn from any device powered by the system. This condition can be reported to the central station.
(See location 37, page 23)
Box Tamper
- The NX-8 has an input for a normally closed tamper switch (see terminal drawing). The Box Tamper
can be programmed to report and/or sound the siren and/or the keypad. These terminals can be enabled or disabled
in programming. (See locations 37 and 39, page 23)
Built In Siren Driver
- The NX-8 has a built-in 112db siren driver. When desired, this built-in driver can be easily
converted to a 1 amp voltage output through programming. (See location 37, page 23)
Bypass Toggle
- This feature will enable the end user to toggle (turn on or off) the bypass of an interior zone with the
system armed by pressing the [Bypass] key. (See location 23, page 19)
Call Back
- When enabled, the control will use the call back phone number to call the download computer before
beginning a download. (See location 21, page 18)
Cancel
- If enabled, the NX-8 will send a "Cancel" report if when the system is disarmed and the [Cancel] button is
pressed within 5 minutes of an alarm. Once the [Cancel] key is pressed, the "Cancel" L ED will illumi nate until the
central station acknowledges the "Cancel" report. ADialer Delay@ must be enabled in the ACharacteristic Select@ of
locations 110-149. (See location 23, page 19)
Code Required Options
- The NX-8 can be programmed to require a code for bypassing zones and/or initiating a
download using the [r]-[9]-[8] or [r]-[9]-[9] function. (See locations 23 and 41, pages 19 and 24)
NX-8 Control
5
Page 6
Communication Formats
- The NX-8 can report in multiple formats. It is recommended that you use Contact ID or
SIA formats if possible. If you wish to report to a pager or in a 4+2 format to a central station, you must program each
code to be reported. (See locations 56-83 and 111-149, pages 28-30 and 35-38)
Cross Zoning
- This feature requires two or more trips on a zone or zones programmed as "cross zones" within a
specified time before reporting an alarm. During the time between trips, the NX-8 can be programmed to sound the
keypad and/or the siren. The NX-8 can also be programmed to report an alarm after two or more trips on the same
zone. (See locations 37, 39, 40 and 110-149, pages 23-24, 35-38)
Dual / Split / Multiple Reports
- The NX-8 can send communication reports to three different phone numbers for
dual, split or multiple reports selectable by event or partition. (See locations 4, 10, and 16, pages 14-17)
Duress Code
- If a duress code is programmed the NX-8 will send a duress signal whenever the panel is armed or
disarmed with this code. If open/close reports are sent, the user code will be 254. (See location 44, page 25) Dynamic Battery Test - The NX-8 can be programmed to perform a Dynamic Battery Test for a sele cted duratio n the
first time the panel is armed or disarmed every day, as well as by pressing [r][4] Test Function. If the panel is not
armed or disarmed during the day, it will perform the test at midnight. The NX-8 can also be programmed to perform a
missing battery test every 12 seconds. (See locations 37 and 40, pages 23 and 24)
Entry-Guard
- This unique low level arming mode has been developed to reduce the most common source of false
alarms. When armed with the AInstant@ LED on, the opening of any zones designated as "Entry Guard zone" will
initiate the keypad sounder and start the entry delay before creating an alarm. All other zones will function as normal.
This arming mode will encourage system owners to use their system more frequently when the premises are
occupied. (See locations 111-149, pages 35-38)NOTE: For UL installations, this feature shall be disabled.
Exit Error
- If enabled, the NX-8 will send an "Exit Error Report" if an entry/exit zone is faulted at the instant the exit
delay expires. This report will be sent along with the user number that armed the system, if the panel is not disarmed
before the entry delay expires. The alarm report will also be sent. Even if this feature is not enabled, the siren will
sound if any entry/exit zone is faulted at the instant the exit delay expires. (See location 23, page 19)
Expander Trouble
- The NX-8 will report expander trouble to the central station if enabled. This condition will
illuminate the "Service" LED on the keypad even if not reported. NOTE: The keypads are considered expanders. The
number of the expansion devices reported can be found on page 54. (See location 37, page 23)
Fail to Communicate
- The NX-8 will illuminate the "Service" LED if a report fails to reach the central station. If
enabled, when the next report is successfully communicated, a Fail to Com municate code will be reported. (See
location 37, page 23)
Fire Alarm Verification
- When enabled, the NX-8 will verify a Fire alarm by requiring more than one trip on a smoke
detector within a specified time before creating an alarm. (See location 40, page 24) This feature is not approved
for residential use in California.
Force Arming
- When enabled, the NX-8 can be Force Armed with zones violated. Under this condition, if a force
armable zone is not secure, the "Ready" LED will flash. At the end of the exit delay, these zones will become
bypassed. If these zones become secured any time during the arming cycle, they will be unbypassed and active in the
system. If "Bypass Report" is enabled, the force arming zones can be programmed to report bypass when they are
Force Armed (default), or to not report bypass even if "Bypass Report" is enabled. (See locations 37, and 111-149,
pages 23 & 35-38) NOTE: For UL installations, this feature shall be disabled.
Ground Fault
- If the NX-870 is used, a fault of the earth ground can be reported to the central station. If it is not
reported, this condition will illuminate the "Service" LED on the keypad. (See location 37, page 23) Group Bypass - A designated group of zones can be programmed to bypass by pressing [Bypass]- [0]-[Bypass]-
[Bypass] prior to arming. (See locations 111-149, pages 35-38) NOTE: For UL installations, this feature shall be
disabled.
Immediate Restore By Zone
- The NX-8 can be programmed to send alarm and restore reports as soon as they
occur, or wait until the siren time has expired. (See location 37, page 23) Internal Event Log - Up to 185 events can be stored in memory along with the date and time of the event. These
events can later be viewed through downloading. All reportable events report to the log.
Keypad Activated Panics
- The NX-8 has three keypad activated panics that will send reports to the central station:
Auxiliary 1 (Fire), Auxiliary 2 (Medical), and Keypad Panic. Auxiliary 1 will activate the steady (Fire) siren, Auxiliary 2
will sound the keypad, and the Keypad Panic can be programmed to be silent or audible (sound siren). (See location
23, page 19)
6
NX-8 Control
Page 7
Keypad Sounder Control
location 39, page 23)
- The NX-8 can be programmed to sound the keypad sounder for certain events. (See
Keypad Tamper
- If enabled, the NX-8 will disable the keypad for 60 seconds and communicate a tamper signal to the
central station if 30 keypresses are entered without producing a valid code. (See location 23, page 19)
Keyswitch Arm/Disarm
- Any zone on the NX-8 can be programmed as a keyswitch zone. If this is done, a
momentary short on this zone will arm/disarm the control. If opening/closing reports are sent, the user code will be 99.
(See "Default Zone Types", page 20)
LED Extinguish
- This feature will extinguish all LED=s on the keypad, except the "Power" LED, after 60 seconds
without a keypress. Pressing any numeric key will illuminate all LED=s. (See location 23, page 19)
Local Programming Lockout
- This feature will disable programming of all locations or specified locations from the
keypad. (See location 21, page 18)
Log Full Report
Lost Clock Service Light
- A report can be sent to the central station when the event log is full. (See location 37, page 23)
- The NX-8 can be programmed to illuminate the "Service" LED when the internal clock has
an invalid time due to power loss. (See location 37, page 23) Manual Test- The NX-8 can be programmed to perform a bell and/or communicator test w hen [r]-[4] is entered while
the system is in the disarmed state. (See location 37, page 23)
On Board Zone Disable
- The eight zones on the NX-8 panel can be disabled in order to have a completely wireless
alarm system. (See location 37, page 23)
Partitions
- The NX-8 can be partitioned into a maximum of eight separate systems with distinct reporting codes, user
codes, and operating features for each system. (See locations 26 - 36, pages 21 - 22)
Program Code
- The factory default for the "Go To Program" code is [9]-[7]-[1]-[3] when using a 4-digit code or, if the
6-digit option is used, the default is [9]-[7]-[1]-[3]-[0]-[0]. The program code can also be used as an Arm/Disa rm code.
If used as an Arm/Disarm code, and open/close reports are sent, the user code will be 255. (See location 43, page
24)
Quick Arm Feature
- The NX-8 has a one button "Quick Arm" feature which can be used to arm the system by
pressing the [Exit] key or the [Stay] key on the keypad. If closing reports are sent, the user code will be 98. (See
location 23, page 19)
Recent Closing
- If enabled, the NX-8 will send a "Recent Closing Report" to the central station if an alarm occurs
within 2 minutes after the panel is armed. The user number that armed the system will also be sent. (See location
23, page 19)
Re-exit
- The NX-8 has the ability to restart the exit delay for a quick exit without disarming the system by pressing
the [Exit] key while the system is armed. (See location 23, page 19)
Shutdown
- This mode will cause the keypads to turn off all LED=s, except the "Power" LED, and not accept
keypresses. (See location 21, page 18)
Siren Blast For Arming
- The NX-8 can be programmed to give a one second siren blast when the panel is armed, at
the end of the exit delay, or when the central station receiver acknowledges the closing report. It can also give one
blast for remote (keyswitch) arming and two blasts for remote disarming. (See location 37, page 23) Note
: Remote
arming shall not be enabled in SIA classified installations.
Siren Supervision
- The NX-8 has a ASiren Supervision@ circuit that will constantly monitor the siren on the NX-8 and
can be programmed to report if the wires are cut. (See location 37, page 23)
Silent Exit Option
- The exit delay can be silenced by pressing [r]-[Exit] before arming the control panel or when
using the re-exit feature.
Start/End Programming and End Downloading
- A report can be sent when local programming is started and
ended. A report can also be sent when a download session ends. (See location 37, page 23)
Swinger Shutdown
- This feature allows a zone or zones to be automatically bypassed after a specified number of
alarms. When a zone is tripped, the alarm ‘counter’ reflects “1” in memory. If a new (first) alarm is detected in a
different zone, the counter remains at “1”. If an alarm is detected on a previously tripped zone, the count increments to
“2”. The ‘counter’ will increment each time an alarm is detected on a zone with multiple trips. Bypassing will occur on
the zone that causes the count to equal the number programmed in location 38; the ‘counter’ will reset to zero (0); and
NX-8 Control
7
Page 8
begin a new trip count where the next alarm will set the ‘counter’ to 1. If immediate restore is enabled in location 37,
the alarms (and restores, if enabled) will be sent as they occur. If immediate restore is not enabled, a second or
subsequent alarm will not be sent until the siren times out. (See location 37 and 38, page 23) Factory default is 1.
Telephone Line Monitor
- The NX-8 has a Telephone Line Monitor that monitors the voltage and current of the
telephone line for a detection of a faulted phone line. This condition can also be reported to the central station. If the
report is enabled, only the Telephone Line Restore will be reported unless the NX-870 is being used. (See locations
37, 39, and 40, pages 23-24)
Temporal Siren Disable
- If disabled, the Fire Siren will be steady and Fire Voltage Out will be the same as Burglary
(continuous). Otherwise, the Fire Siren will be temporal. (See location 37, page 23) NOTE: For UL installations,
do NOT disable.
Tone Sniff Answering Machine Defeat
- If enabled, only one call is required to defeat the answering machine. To use
this feature you must have a Hayes 1200 Smart Modem. From the computer, call the panel as normal. When the
answering machine answers, the panel will hear the tones from the modem and seize the phone line for a download.
(See location 21, page 18)
Two Call Answering Machine Defeat
- If enabled, to defeat an answering machine, two telephone calls must be
made to the premises. On the first call, let the phone ring one or two times. The control panel will detect these rings
and start a 45 second timer, during which, the control panel will answer the next call on the first ring. This is not
recommended for commercial applications. (See location 21, page 18)
Walk-Test Mode
- If enabled, entering [r] [Chime] followed by a user code will allow a walk-through zone test where
all zones become silent and local (non-reporting). During this test the chime light will flash on the LED keypad. Each
time a zone is faulted, the zone light on the LED keypad will illuminate and the chime will sound. The number of the
faulted zone(s) will be displayed on the LCD keypad. It will also be entered into alarm memory and the internal log.
To exit at any time during this mode, enter a user code. Otherwise the AWalk-Test Mode@ will automatically exit after
15 minutes. (See location 41, page 24)
Wireless Sensor Missing/Low Battery
- The NX-8 will send a report to the central station when a wireless sensor
has detected a low battery or has not reported to the receiver. The "Service" LED will illuminate when either condition
exists. (See location 37, page 23)
Zone Bypassed Sounder Alert
- If this feature is enabled, the NX-8 will beep the keypad sounder upon arming if a
zone is bypassed. (See location 23, page 19)
Zone Doubling
- This feature allows you to use the eight zones on the panel as sixteen normally closed zones. When
this feature is used European double E.O.L. configuration cannot be used on the first sixteen zones. THIS FEATURE DOES NOT INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES BEYOND 48. If one of the sixteen zones
must be a fire zone, it must be one of Zones 1 to 8. The corresponding upper zone will become unavailable. For
example, if Zone 6 is a fire zone, then Zone 14 will not be available. (See location 37, page 23)
Zone Types (Configurations)
- The NX-8 has 20 programmable Zone Types that determine how each zone will
function and report. The default Zone Types are listed on page 20. (See locations 111-149, pages 35-38)
8
NX-8 Control
Page 9
PROGRAMMING THE LED KEYPADS
]
This section describes how to program the address and partition of each keypad as well as the options that are
available. The address of the keypad is important because this is how the panel supervises the keypads.
The factory default for the Master code is [1]-[2]-[3]-[4] when using a 4-digit code or [1]-[2]-[3]-[4]-[5]-[6] for a 6-digit
code. The factory default for the "Go To Program" code is [9]-[7]-[1]-[3] for a 4-digit code or [9]-[7]-[1]-[3]-[0]-[0] for a
6-digit code.
[r] [9] [2] (Applies to LED keypad ONLY)
1) Enter [r] [9] [2] [program code].
2) Enter the zone number (1 - 48) you want the keypad to start at.
3) Enter [r] to save and exit.
[r]-[9]-[3] Set keypad options
1) Enter [r]-[9]-[3] [program code]- The "Service" LED will flash.
2) LEDs 1-8 can now be toggled on/off to enable/disable the following functions:
3) After enabling/disabling the desired functions press [r]
LED
[r]-[9]-[4] Set Keypad Number and Partition
[r]-[9]-[5] Set elapsed increments since last autotest
[r]-[9]-[6] Set system date
[r]-[9]-[7] Set system clock
Keypad Feature Enabled
1 RESERVED. DO NOT PROGRAM THIS AT ALL!
2 Enable Silent Keypad option. Silences the entry/exit sounder & chime only.
3 Enable Ding Dong sound for Chime - If off, chime will be a single tone. (See location 40, page 24)
4 Enable Keypress Silence option
(silences the pulsing keypad sounder for 5 seconds when a key is pressed)
5 Enable Armed Status Suppression
(will not allow the keypad to display faulted or bypassed zones when the system is armed)
6 Enable Panic, Fire, Medical Beeptone
(will sound a short beep to verify that the keypress was accepted)
7 Suppresses the "Service" LED (NOTE: For UL installations, the Service LED shall not be suppressed
(will not allow the "Service" LED to illuminate for any reason. If there is a system trouble, pressing [r]-[2
will still show the service menu.)
8 Enable multi-partition viewing
(enables temporary viewing of all partitions by pressing [r]-[1]-[partition number])
1) Enter [r]-[9]-[4]-[program code]- The "Service" LED and the "Instant" LED will flash.
2) Enter the keypad number (1-8)
3) Press [r]- The "Instant" LED will illuminate steady and the"Service" LED will remain flashing.
4) Enter the partition number for the keypad (The keypad will automatically exit this mode at this time)
1) Enter [r]-[9]-[5]-[program code]-The "Service" LED will flash.
2) Enter [100's digit] -[10's digit]-[1's digit]-[#]
1) Enter [r]-[9]-[6]-[master code]. The "Service" LED will flash.
2) Enter [day of week (1=Sun)]-[month 10's digit]-[month 1's digit]-[day 10's digit]
1) Enter [r]-[5]-[master code] - The "Ready" LED will flash.
2) Enter the 2 digit user number (always 2 digits such as "03" for user 3) - The "Ready" LED will illuminate
steady.
3) Enter the new user code designated for that individual - The "Ready" LED will flash indicating that the code
was accepted. If it rejects the code, the sounder will beep 3 times,
Note for NX1300 Series LED Keypad
: The zone lights will illuminate indicating the first digit of the “user
code”. (Lights 1-8 on = code is blank; lights 1-8 off = “0”; lights 1 and 8 = “9”.) Use the up and down scroll
keys to view the next digit or enter a new 4- or 6-digit “user code”. While using the scroll keys you can
change any digit by entering a new digit. This will advance you to the next digit.
4) If another user code needs to be programmed, return to step 2.
5) Press [#] while the "Ready" LED is flashing to exit the User Code Programming Mode.
ASSIGNING AUTHORITY LEVEL:
1) Enter [r]-[6]-[master code] - The "Ready" LED will flash.
2) Enter [2 digit user number] (always 2 digits such as 03 for user 3) - The "Ready" LED will illuminate steady
and the "Instant" LED will flash. Refer to the chart below for the description of each LED. Turn the LED on
for the features that you desire.
LED ATTRIBUTES IF LED 8 IS OFF
1 Reserved
2
Arm Only
3
Arm Only After Close Window
4
Master arm/disarm (can program other codes)
5
Arm/disarm code
6
Allowed to bypass zones (see location 23)
7
Code will send open / close reports
8
If this LED is on, LEDs 1-7 will use the chart to the right
LED
1
2
3
4
5
6
7
8
Activate output #1
Activate output # 2
Activate output # 3
Activate output # 4
Arm/disarm
Bypass Zones
Open / Close Reporting
If this LED is off, LEDs 1-7 use the chart to the left
ATTRIBUTES IF LED 8 IS ON
3) Enter [r] - The "Instant" LED will illuminate steady.
This moves you to the partition enable. (This tells the system what partition this user can arm/disarm.
LEDs 1-8 illuminate for each partition that the user has authorization for. To change any of these
numbers, press 1-8 to permit or deny access to the user. (Example: If LED #2 is lit, then user has
assigned access to that partition. By pressing the [2] key, the LED will go off indicating the user has
been denied access to that partition.)
4) Enter [r]
This returns you back to step 2 above. At this point you may enter another user number to assign
attributes for. You may continue this procedure until you have assigned authority levels to all user
numbers - or - you may press [#] key to exit the Assigning Authority Level Program.
NOTE
: Any master arm/disarm code can add or change a user code if the master code has access to the
same partitions as the code being added/changed. Consequently, when programming the user co des
for a partitioned system, leave at least one code (can be "go to program code" if enabled in location
43) access to all partitions or you will not be able to add new users. If you desire the end user to be
able to add new codes, you must remove the partition authority from all blank codes.
[r]-[9]-[8]
Pressing [r]-[9]-[8] while the system is disarmed will cause the control to do a callback for a do wnload.
NOTE: A valid user code may be required after [r]-[9]-[8] if enabled in location 41, page 24.
[r]-[9]-[9]
Pressing [r]-[9]-[9] while the system is disarmed will cause the control panel to seize the phone line for a
download. NOTE: A valid user code may be required after [r]-[9]-[9] if enabled in location 24.
10
NX-8 Control
Page 11
PROGRAMMING THE NX-8 CONTROL PANEL
ENTERING THE PROGRAM MODE: To enter the Program Mode, press [r]-[8]. At this time, the five function LEDs
(Stay, Chime, Exit, Bypass, & Cancel) will begin to flash. Next, enter the "Go To Program Code" (FACTORY
DEFAULT IS [9]-[7]-[1]-[3]). If the "Go To Program Code" is valid, the "Service" LED will flash and the five function
LEDs will illuminate steady. You are now in the Program Mode and ready to select the module to program.
SELECTING THE MODULE TO PROGRAM: Since all modules connected to the NX-8 are programmed through the
keypad, the module you are programming should be the first entry. To program the NX-8 Control Panel, enter [0]-[#].
The [0] is the module number of the control and the [#] is the entry key. Other module entry numbers can be found in
their corresponding manuals.
PROGRAMMING A LOCATION: Once the number of the module to be programmed has been entered, the "Armed"
LED will illuminate, indicating it is waiting for a programming location to be entered. Any location can be accessed by
directly entering the desired programming location followed by the pound [#] key. If the location en tered is a valid
location, the "Armed" LED will extinguish, the "Ready" LED will illuminate and the binary data for the first segment of
this location will be shown by the zone LED's. While entering new data, the "Ready" LED will begin flashing to
indicate a data change in process. The flashing will continue until the new data is stored by pressing the [r] key.
Upon pressing the [r] key, the keypad will advance to the next segment and display its data. This procedure is
repeated until the last segment is reached. Pressing the [#] key will exit from this location, and the "Armed" LED will
illuminate again waiting for a new programming location to be entered. If the desired location is the next sequential
location, press the [POLICE] key. If the previous location is desired press the [FIRE] key. If the same location is
desired press the [MEDIC] key. To review the data in a location, repeat the above procedure, pressing the [r] key
without any numeric data entry. Each time the [r] key is pressed, the programming data of the next segment will be
displayed for review.
EXITING A LOCATION: After the last segment of a location is programmed, pressing the [r] key will exit that location,
turn the "Ready" LED off and the "Armed" LED on. The [r] key must be pressed or the data will not be saved. To exit
before the last segment, press [#]. As before, you are now ready to enter another programming location. If an attempt
is made to program an invalid entry for a particular segment, the keypad sounder will emit a triple error beep (beep,
beep, beep), and remain in that segment awaiting a valid entry.
EXITING THE PROGRAM MODE : When all the desired changes in programming have been made, it is time to exit
the program mode. Pressing the [Exit] key will exit this programming level, and go to the "Select a Module To
Program" level. If no additional modules are to be programmed, pressing the [Exit] key again will e xit the program
mode. If there is a module to be programmed, it may be selected by entering its address followed by the [#] key (see
"Selecting the Module To Program" above). The procedure for programming these devices is the same as for the
control panel, except the locations will be for the module selected.
TYPES OF PROGRAMMING DATA
Programming data is always one of two types. One type of data is numerical and can take on values from 0 -15 or 0 255 depending on the location's segment. The other type of data is a feature selection type. Feature selection data is
used to turn features on or off. Use the following procedures when working with these two data types:
NUMERICAL DATA: Numerical data is programmed by entering a number from 0-255 on the numeric keys of the
system keypad. To view the data in a location, a binary process is used. With this process, the LED=s for zones 1
through 8 are utilized, and the numeric equivalents of their illuminated LED=s are added together to determine the data
in a programming location. The numeric equivalents of these LED=s are as follows:
Zone 1 LED = 1
Zone 5 LED = 16
Example: If the numerical data to be programmed in a location is "66", press [6]-[6] on the keypad. The LED=s for
Zone 2 and Zone 7 will become illuminated indicating 66 is in that location (2 + 64 = 66). See this example on page
12. Once the data is programmed, press the [r] key to enter the data and advance to the next segment of that
location. After the last segment of a location is programmed, pressing the [r] key will exit that location, turn the
"Ready" LED off and the "Armed" LED on. As before, you are now ready to enter another programming location. If an
attempt is made to program a number too large for a particular segment, the keypad sounder will emit a triple beep,
indicating an error, and remain in that segment awaiting a valid entry.
On the LCD keypad, the number in the location will be displayed. For locations with a maximum of 15, the
hexidecimal equivalent will be displayed in parenthesis. Example: 11 (B) or 14 (E).
Zone 2 LED = 2
Zone 6 LED = 32
Zone 3 LED = 4
Zone 7 LED = 64
Zone 4 LED = 8
Zone 8 LED = 128
NX-8 Control
11
Page 12
PROGRAMMING EXAMPLE – Figure 1 (Numerical Data)
Advances to the next
Zone 1 LED = 1
Zone 4 LED = 8
To change data in a
segment, enter the data
followed by []
Enters the previous
programming “location”.
Data = 9
}
Returns to the “location” just
programmed.
Zone 2 LED = 2
Zone 7 LED = 64
programming “location”.
Data = 66
}
Pressing [#] will exit a
location without
changing the data in
the current segment.
Press the key on the numeric keypad that corresponds to the feature you wish to enable/disable. When an LED is “on, a feature
is enabled; when “off” the feature is disabled. For example: With the 1, 5, & 7 LEDs “on”, Quick Arm, Audible Keypad Panic and
Keypad Auxiliary 2 are enabled.
FEATURE SELECTION DATA: Feature selection data will display the current condition (on or off) of eight features
associated with the programming location and segment selected. Pressing a button on the touchpad (1 thru 8) that
corresponds to the "feature number" within a segment, will toggle (on/off) that feature. Pressing an y numeric key
between [1] and [8] for selection of a feature, will make the corresponding LED illuminate (feature ON). Press the
number again, and the LED will extinguish (feature OFF). You will see that numerous features can be selected from
within one segment. For instance, if all eight features of a segment are desired, pressing [1]-[2]-[3]-[4]-[5]-[6]-[7]-[8] will
turn on LED's 1 thru 8 as you press the keys, indicating that those features are enabled.
numbers of the enabled features will be displayed. However, the features not enabled will display a hyphen (-).
desired setting of features is selected for this segment, press the [r] key. This will enter the data and automatically
advance to the next segment of the location. When you are in the last segment of a location and press the [r] to enter
the data, you will exit that location. This will now turn the "Ready" LED off and the "Armed" LED on. As before, you
are now ready to enter another programming location.
LCD Keypad Users Note: The
LOADING FACTORY DEFAULTS
To load the factory defaults, enter the program mode using the procedure on page 13, then type [9]-[1]-[0]-[#]. The
keypad will beep 3 times indicating that the loading is in progress. The loading takes about 6 seconds.
ENROLLING MODULES AND KEYPADS
For supervision purposes, the NX-8 has the ability to automatically find and store in its memory, the presence of all
keypads, zone expanders, wireless receivers, and any other module connected to the data terminal. This allows these
modules to be supervised by the control panel. To enroll the modules, enter the Program Mode of the NX-8 control
panel as described on page 13. When the Program Mode is exited, the NX-8 control will automatically enroll the
devices. The enrolling process takes about 12 seconds, during which time the "Ser vice" LED will illuminate. User
codes will not be accepted during the enrolling process. If a speaker is attached to the NX-8, it will click at this time. If
a siren or bell is attached to the NX-8, it will sound for about 1 second. Once a module is enrolled, if it is not detected
by the control, the "Service" LED will illuminate.
L QUICK START INSTALLATION
For most routine installations, the "Quick Start" option will allow for enabling a majority of the options available with the
NX-8, when communicating in Contact ID or SIA formats and without partitioning. The "Quick Start" locations can be
identified by the L symbol.
CONTROL PANEL PROGRAMMING LOCATIONS
L LOCATION 0 - PHONE NUMBER 1 (20 segments, numerical data)
The first telephone number is programmed in location 0. A "14" indicates the end of the phone number. Delays of four
seconds can be programmed at any point in the phone number by programming a "13" in the appropriate segment. If
tone dialing is desired, program a "15" in the segment where tone dialing should begin. If the entire number should be
tone dialing, program a "15" in the first segment. Program an A11" for a Ar@, and a A12" for a A#@.
cancel on a non- call waiting line will prevent successful connection to the central station.
Caution: A call-waiting
L LOCATION 1 - ACCOUNT CODE FOR THE PHONE #1 (6 segments, numerical data)
The account code sent when Phone #1 is dialed is programmed in location 1. Program a A10" in the segment
immediately after the last digit of the account code. If the account code is 6 digits long, program all 6 segments.
L LOCATION 2 - COMMUNICATOR FORMAT FOR PHONE #1 (1 segment, numerical data)
Location 2 contains the communicator format used to transmit to the receiver connected to Phone #1. Consult the
instructions for your central station receiver to determine which format is compatible. Select a format from the list on
the following page. If you require a format other than those listed, review the override options described in location 18,
to build the appropriate format. A "15" must be programmed in location 2 in addition to the entries in location 18 in
order to create a special format. If this location contains a "0", the built-in communicator will be disabled, and the NX8 will function as a local only control.
L LOCATION 3 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE # 1 (2 segments, numerical data)
After the
Segment 1- Dial attempts: Location 3, Segment 1 is used to enter the number of dial attempt s ( 1 to 15 Attempts ) the
communicator will make to Phone #1 before ending the notification process. Factory default is "8" and the
communicator will make eight (8) attempts to the first number.
NX-8 Control
13
Page 14
Segment 2- Phone #1 Backup Control: Programming a "0" in Segment 2 of this location will cause the NX-8 to make
the designated number of attempts to Phone #2 before setting the "Fail To Communicate" condition and stop
reporting. Programming a "1" in this segment will cause the NX-8 to stop trying to communicate after the designated
number of attempts have been made to Phone #1. If a "2" is programmed in this segment, it will cause the NX-8 to
make the dial attempts in increments of two. The first two attempts will be made to Phone #1, the next two attempts to
Phone #2, then repeating until the total number of attempts designated in Segment 1 is completed.
COMMUNICATOR FORMAT SELECTIONS
DATA
FORMAT
0 Local
1 Universal 4+2
2 3+1 fast (or 4+1)
3 Reserved
4 Pager
5 3/1 or 4/1 slow
6 3/1 or 4/1 slow 1800hz transmit 1400hz handshake double round parity 20 p.p.s. hex capability
7 3/1 or 4/1 fast
8 3/1 or 4/1 fast
9 3/1 or 4/1 fast with parity 1800hz transmit 2300hz handshake single round w/parity 40 p.p.s. hex capability
10 3/1 or 4/1 fast with parity 1800hz transmit 1400hz handshake single round w/parity 40 p.p.s. hex capability
11 4+2 express
12 4+2 fast
13 Ademco Contact ID
14 SIA
15 Custom format
Communicator is disabled
Two digit event code 1800hz transmit 2300hz handshake double round parity
40pps
One digit event code 1900Hz transmit 1400Hz handshake double round parit y
p.p.s.
DTMF (see pages 52-53)
FSK (see pages 52-53)
(See location 18, page 18)
DESCRIPTION
REPORTING EVENTS TO PHONE NUMBER 1
Phone #1 has two programming locations that are used to select which events are reported to this phone number.
Location 4 is used to select which events are reported to Phone #1. Location 5 is used to select which partitions are
reported to Phone #1. If dual or split reporting is not desired, location 4 should be used to select all events to Phone
#1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired, and the split is based
on the event type (such as alarm, open/close, etc.), location 4 should be used to select only those events that should
be reported to Phone #1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired,
and the split is based on partition, location 4 should be programmed as a "0" and location 5 should be used to select
those partitions that should be reported to Phone #1. If no events should be reported to Phone #1, both locations
should be programmed as "0" (disabling all options).
2 = Opening and Closings.
3 = Zone Bypass and Bypass Restores.
4 = Zone Trouble and Trouble Restores.
5 = Power Fail, Low Battery, Power Restore, and Low Battery Restore.
6 = Bell Cut , Telephone Line Cut, Bell Cut Restore, Telephone Line Restore.
7 = Test Reports.
8 = Start and End programming, Download complete.
14
NX-8 Control
Page 15
Segment 2: 1 = Zone and Box Tamper and Tamper Restore.
2 = Auxiliary Power Overcurrent, Ground Fault, and Restore for both.
3 = Wireless Sensor Missing and Restore.
4 = Wireless Sensor Low Battery and Restore.
5 = Expander Trouble and Restore.
6 = Fail To Communicate.
7 = Reserved.
8 = Reserved.
Location 5 is used when events to be reported to a phone number are based upon the partition regardless of the
event. If this location is used, location 4 should be programmed as "0".
Phone #2 is programmed in location 6. A "14" indicates the end of the phone number. Delays of four seconds can be
programmed at any point in the phone number by programming a "13" in the appropriate segment. If tone dialing is
desired, program a "15" in the segment where tone dialing should begin. If the entire number should be tone dialing,
program a "15" in the first segment. Program an A11" for a Ar@, and a A12" for a A#@.
non- call waiting line will prevent successful connection to the central station.
Caution: A call-waiting cancel on a
L LOCATION 7 - ACCOUNT CODE FOR THE PHONE #2 (6 segments of numerical data)
The account code sent when Phone #2 is dialed is programmed in location 7. Program a A10" in the segment
immediately after the last digit of the account code. If the account code is 6 digits long, program all 6 segments. If
this location is left unprogrammed, account code 1 will be used when the second phone number is dialed.
L LOCATION 8 - COMMUNICATOR FORMAT FOR PHONE # 2 (1 segment, numerical data)
Location 8 contains the communicator format used to transmit to the receiver connected to Phone #2. Consult the
instruction manual for your central station receiver to determine which format is compatible, and select from the 15
formats listed on page 14. If you require a format other than those listed, review the override options described in
Location 18 to build the appropriate format. A "15" must be programmed in location 8 in addition to the entries in
location 18 in order to create a special format. If this location contains a "0", format 1 will be used when Phone #2 is
dialed.
LOCATION 9 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE #2 (2 segments, numerical data)
Segment 1, Dial attempts: Segment 1 of Location 9 is used to enter the number of dial attempts (1 to 15 attempts)
the communicator will make to Phone #2 before ending the notification process. Factory default is "8" and the
communicator will make the same number of attempts as those programmed in location 3.
Segment 2, Phone #2 Backup Control: Programming a " 0" in Segment 2 of this location will cause the NX-8 to make
the designated number of attempts to Phone #1 before setting the "Fail To Communicate" condition and stop
reporting. Programming a "1" in this segment will cause the NX-8 to stop trying to communicate after the designated
number of attempts have been made to Phone #2. If a "2" is programmed in this segment, it will cause the NX-8 to
make the dial attempts in increments of two. The first two attempts will be made to Phone #2, the next two attempts to
Phone #1, then repeating until the total number of attempts designated in Segment 1 is completed.
NX-8 Control
15
Page 16
REPORTING EVENTS TO PHONE NUMBER 2
Phone #2 can be used to back up Phone #1 or for a second receiver to multi-report or split report events. Phone #2
has two programming locations that are used to select which events are reported to this phone number. Location 10 is
used to select which events are reported to Phone #2, and location 11 is used to select which partitions are reported
to Phone #2. If dual or split reporting is not desired, location 10 and location 11 should be left at the factory default of
"0". If multi-reporting or split reporting is desired, and the split is based on the event type (such as alarm, open close
etc.), location 10 should be used to select only those events that should be reported to Phone #2, and location 11
should be left at the factory default of "0". If dual or split reporting is desired, and the split is based on partition, then
location 10 should be programmed as "0", and location 11 should be used to select those partitions that should be
reported to the Phone #2. If no events should be reported to Phone #2, both locations should be "0".
LOCATION 10 - EVENTS REPORTED TO PHONE #2 (2 segments of feature selection data)
Segment 1: 1 = Alarms and Alarm Restores.
2 = Opening and Closings.
3 = Zone Bypass and Bypass Restores.
4 = Zone Trouble and Trouble Restores.
5 = Power Fail, Low Battery, Power Restore, and Low Battery Restore.
6 = Bell Cut , Telephone Line Cut, Bell Cut Restore, Telephone Line Restore.
7 = Test Reports.
8 = Start and End programing, Download complete.
Segment 2:1 = Zone and Box Tamper and Tamper Restore.
2 = Auxiliary Power Overcurrent and Ground Fault and Restore for both.
3 = Sensor Missing and Restore.
4 = Sensor Low Battery and Restore.
5 = Expander Trouble and Restore.
6 = Fail To Communicate.
7 = Reserved.
8 = Reserved.
Location 11 is used when events to be reported to a phone number are based upon the partition regardless of the
event. If this location is used, location 10 should be "0".
Phone #3 is programmed in location 12. A "14" indicates the end of the phone number. Delays of four seconds can
be programmed at any point in the phone number by programming a "13" in the appropriate segment. If tone dialing is
desired, program a "15" in the segment where tone dialing should begin. If the entire number should be tone dialing,
program a "15" in the first segment. Program an A11" for a Ar@, and a A12" for a A#@.
non- call waiting line will prevent successful connection to the central station.
The account code sent when Phone #3 is dialed is programmed in location 13. Program a A10" in the segment
immediately after the last digit of the account code. If the account code is 6 digits long, program all 6 segments. If
location 6 is left unprogrammed, account code 1 will be used when the Phone #3 is dialed.
LOCATION 14 - COMMUNICATOR FORMAT FOR PHONE #3 (1 segment, numerical data)
Location 14 contains the communicator format used to transmit to the receiver connected to phone #3. Consult the
instruction manual for your central station receiver to determine which format is compatible, and select from the 15
formats listed on page 14. If you require a format other than those listed, review the override options described in
Location 18 to build the appropriate format. A "15" must be programmed in location 14 in addition to the entries in
location 18 in order to create a special format. If this location contains a "0", format 1 will be used when Phone #3 is
dialed.
16
Caution: A call-waiting cancel on a
NX-8 Control
Page 17
LOCATION 15 - DIAL ATTEMPTS/BACKUP CONTROL FOR PHONE #3 (2 segments, numerical data)
Segment 1, Dial Attempts: Segment 1 of Location 15 is used to enter the number of dial attempts (1 to 15 attempts)
the communicator will try to Phone #3 before ending the notification process. Factory default is "8" and the
communicator will make the same number of attempts as those programmed in location 3.
Segment 2, Phone # 3 Backup Control: Programming a "0" in Segment 2 of this location will cause the NX-8 to
make the designated number of attempts to Phone #2 before setting the "Fail To Communicate" condition and stop
reporting. Programming a "1" in this segment will cause the NX-8 to stop trying to communicate after the designated
number of attempts have been made to Phone #3. If a "2" is programmed in this segment, it will cause the NX-8 to
make the dial attempts in increments of two. The first two attempts will be made to Phone #3, the next two attempts to
Phone #2, then repeating until the total number of attempts designated in Segment 1 is completed.
REPORTING EVENTS TO PHONE NUMBER 3
Phone #3 can be used for a third receiver to multi-report or split report events. Phone #3 has two programming
locations that are used to select which events are reported to this phone number. Location 16 is used to select which
events are reported to Phone #3, and Location 17 is used to select which partitions are reported to Phone #3. If dual
or split reporting is not desired, location 16 and location 17 should be left at the factory default of "0". If multireporting or split reporting is desired and the split is based on the event type (such as alarm, open/close, etc.), then
location 16 should be used to select only those events that should be reported to Phone #3 and location 17 should be
left at the factory default of "0". If dual or split reporting is desired, and the split is based on partition, then location 16
should be programmed to "0" and location 17 should be used to select those partitions that should be reported to
Phone #3. If no events should be reported to Phone #3, both locations should be "0".
2 = Opening and Closings.
3 = Zone Bypass and Bypass Restores.
4 = Zone Trouble and Trouble Restores.
5 = Power Fail, Low Battery, Power Restore, and Low Battery Restore.
6 = Bell Cut, Telephone Line Cut, Bell Cut Restore, Telephone Line Restore.
7 = Test Reports.
8 = Start and End programming, Download complete.
Segment 2:1 = Zone and Box Tamper and Tamper Restore.
2 = Auxiliary Power Overcurrent and Ground Fault and Restore for both.
3 = Sensor Missing and Restore.
4 = Sensor Low Battery and Restore.
5 = Expander Trouble and Restore.
6 = Fail To Communicate.
7 = Reserved.
8 = Reserved.
Location 17 is used when events to be reported to a phone number are based upon the partition regardless of the
event. If this location is used, location 16 should be "0".
LOCATION 18 - CUSTOM COMMUNICATOR FORMAT (See locations 2, 8, &14)
Segment 1: 1 = On for 1800hz transmit; Off for 1900hz.
2= On for 2300hz handshake; Off for 1400hz.
3= On for cksum parity; Off for double round parity.
4= On for 2 digit event code; Off for 1 digit event code.
5= Reserved.
6= Reserved.
7= On for 20 p.p.s.; Off for 10 or 40 p.p.s.
8= On for 10 p.p.s.; Off for 20 or 40 p.p.s.
Segment 2 :1= On for pager format (no handshake required).
2= On for 1400/2300 handshake.
3= Reserved
4= Reserved.
5= On for Contact ID.
6= On for SIA.
7= On for Contact ID or 4+3.
8= On for DTMF.
Location 19 contains the eight digit access code the NX-8 must receive from the downloading software before the
panel will permit downloading to occur. The factory default code is 84800000.
L LOCATION 20 - NUMBER OF RINGS TO ANSWER (1 segment, numerical data)
Location 20 contains the number of rings to answer for a download. Enter a number from A0" (disabled) to "15".
Factory default is "8" and the NX-8 will answer on 8 rings.
L LOCATION 21 - DOWNLOAD CONTROL (1 segment, feature selection data)
Location 21 contains the feature selections for the controlling of download sessions. The following features can be
enabled or disabled using this location. (See the feature definitions beginning on page 5)
Segment 1:
1 - On enables two call answering machine defeat.
2 - On enables tone sniff answering machine defeat.
3 - On requires call back before download session.
4 - Shutdown (can only be viewed from the keypad, must be changed through downloading).
5 - On locks all local programming. (can only be viewed from the keypad, must be changed through
downloading)
6 - On locks programming of all locations associated wit h the communicator (can only be viewed from the
keypad, must be changed through downloading)
7 - On locks out download section. (can only be viewed from the keypad, must be changed through
downloading. If "On", locations 19 - 22 cannot be viewed from the keypad; can only be viewed
from the keypad when "Off".)
8 - On enables call back at auto test interval.
L LOCATION 22 - DOWNLOAD CALL BACK NUMBER (20 segments, numerical data)
If a telephone number is programmed into this location, and "Require Callback" is enabled in location 21, the control
panel will hang up for approximately 36 seconds (ensuring that the calling party has disconnected), and then call back.
If tone dialing is desired, program a "15" in the segment where tone dialing should begin. If the entire number should
be tone dialing, program an A15" in the first segment. Four-second delays can be obtained anywhere in the sequence
by programming a "13" in the appropriate delay location. WARNING: THE CALLBACK PHONE NUMBER SHOULD
ALWAYS BE REVIEWED FOR ACCURACY BEFO R E DISCONNECTING.
18
NX-8 Control
Page 19
L LOCATION 23 - PARTITION 1, FEATURE AND REPORT SELECTIONS (3 segments, feature selection data)
Location 23 is used to enable certain features that can be accessed or are visible to the user from the keypad of the
system. In addition, certain communicator reports are enabled in location 23. Each of these features can be enabled
by partition. For additional partition information see locations 88-109 on pages 32-35. If the feature selection location for any partition is left blank, that partition will use this location for the feature selection.
This location contains 3 segments of 8 features each. (See the feature definitions beginning on page 5.)
Segment 1:1 - On enables the Quick Arm feature.
2 - On enables the Re-exit feature.
3 - On enables the Automatic Bypass feature. Factory default is “enabled.”
4 - On enables the Silent Keypad Panic feature (overrides the audible panic selection).
5 - On enables the Audible Keypad Panic feature.
6 - On enables the Keypad Aux 1 feature (FIRE).
7 - On enables the Keypad Aux 2 feature (MEDICAL).
8 - On enables the Keypad Multiple Code Attempt Tamper feature.
Segment 2 :1 - On enables the LED Extinguish feature.
2 - On enables the Require Code for Bypassing feature.
3 - On enables the Zone Bypassed Sounder Alert feature.
4 - On enables the AC Power/Low Battery Sounder Alert feature.
5 - On enables Bypass toggle.
6 - On enables Silent Auto Arm.
7 - On enables the Automatic Instant feature.
8 - Reserved.
Segment 3:1 - On enables Opening and Closing reports.
2 - On enables Zone Bypass reporting.
3 - On enables Zone Restore reporting.
4 - On enables Zone Trouble reporting.
5 - On enables Zone Tamper reporting.
6 - On enables the Cancel reporting. Factory default is “enabled.”
7 - On enables the Recent Closing report. Factory default is “enabled.”
8 - On enables the Exit Error report. Factory default is “enabled.”
Location 24 is used to program the Entry/Exit times. There are 2 separate Entry/Exit times.
Segment 1, Entry time 1:This is the entry time that will be used when a delay 1 zone type initiates a n
entry delay. Valid entries are 30-255 seconds.
Segment 2, Exit time 1:This is the exit time that will be used for all zones designated as delay 1. Valid
entries are 45-255 seconds.
Segment 3,Entry time 2: This is the entry time that will be used when a delay 2 zone type initiates a n
entry delay. Valid entries are 30-255 seconds.
Segment 4, Exit time 2:This is the exit time that will be used for all zones designated as delay 2. Valid
entries are 45-255 seconds.
NX-8 Control
19
Page 20
DEFAULT ZONE TYPES (Configurations)
Creates an instant yelping siren alarm regardless of the armed state of the control
A trip will start entry delay 1. The lack of a trip during exit delay will enable the
This zone will be instant when the system is armed
ays are being timed. It is delayed during entry and exit delay times. This zone will
This zone will be instant when the system
and no entry or exit delay is being timed. It is delayed during entry and exit delay times. This
Creates an instant silent alarm regardless of the armed state of the control panel. It
. It will
A trip will start entry delay 2. The lack of a trip during exit delay will enable the
Creates an instant silent alarm regardless of the armed state of the
This zone type will arm and disarm the partition or partitions of the control panel
This zone will be instant when the system
and exit delay times. If a
"Cross Zone" is not being timed it will start a "Cross Zone" timer. If a "Cross Zone" is being timed it will
This zone creates an instant alarm whenever it is tripped and the Stay LED
will start entry delay 1. This zone will
bypass when the "Group Bypass" command is entered at the keypad. The lack of a trip during exit delay
This zone will be instant when the system
is armed and no entry or exit delays are being timed. It is delayed during entry/exit delay times. This zone
lly
This zone creates an instant alarm whenever it is
tripped and the Armed LED is on. This zone will bypass when the "Group Bypass" command is entered at
A trip will start entry delay 1. The lack of a trip
This zone type
This zone will be instant
when the system is armed and no entry or exit delay is being timed. It is delayed during entry and exit
This zone type
This zone creates an instant alarm whenever it is tripped and the
A trip will start entry delay 2. The lack of a trip
This zone type
Zones can be programmed to be one of twenty different zone types (configurations). Zone types # 17 - 20 can be used
for wireless or hardwired zones using European double EOL configuration. The default zone types are listed below.
These zone types can be customized by programming locations 110-149.
DATA DESCRIPTION OF DEFAULT ZONE TYPES
"1" DAY ZONE - Instant when system is armed trouble zone when system is disarmed.
"2"
"3"
"4"
"5"
"6" INSTANT - This zone creates an instant alarm whenever it is tripped and the Armed LED is on.
"7"
"8"
"9"
"10"
"11"
"12"
24-HOUR AUDIBLE panel.
ENTRY/EXIT DELAY 1Automatic Bypass or Instant mode if so programmed.
FOLLOWER WITH AUTO- BYPASS DISABLED -
and no entry or exit del
not automatically bypass even if enabled in Segment 1 of Location 23.
INTERIOR FOLLOWER WITH AUTO- BYPASS ENABLED -
is armed
zone will automatically bypass if enabled in Segment 1 of Location 23.
24-HOUR SILENT will not display on the keypad.
FIRE - This zone will light the Fire LED and sound the temporal siren each time the zone is shortedalso rapidly flash the Fire LED indicating a trouble if the zone is open.
ENTRY/EXIT DELAY 2Automatic Bypass or Instant mode if so programmed.
24-HOUR SILENT SUPERVISEDcontrol panel. It will display on the keypad.
KEYSWITCH ZONE -
that it resides in each time the zone is shorted. Keyswitch arming will report as user #99.
INTERIOR FOLLOWER WITH "CROSS ZONE" ENABLED -
is armed and no entry or exit delay is being timed. It is delayed during entry
20
"13"
"14"
"15"
"16"
"17"
"18"
"19"
"20"
create an instant alarm. This zone will automatically bypass when enabled in Segment 1 of Location 23.
INSTANT ENTRY GUARD -
is off. It will start an entry delay time 2 if it is tripped and the system is armed and the Stay LED is on.
ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED - A trip
will enable the Automatic Bypass or Instant mode if so programmed.
INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED -
will bypass when the "Group Bypass" command is entered at the keypad. This zone will automatica
bypass if enabled in Segment 1 of Location 23.
INSTANT WITH GROUP BYPASS ENABLED the keypad.
ENTRY/EXIT DELAY 1 WITH TAMPER ENABLED-
during exit delay will enable the Automatic Bypass or Instant mode if so programmed.
can be used to enable tamper on a wireless transmitter.
INTERIOR FOLLOWER WITH TAMPER AND AUTO-BYPASS ENABLED -
delay times. This zone will automatically bypass if enabled in Segment 1 of Location 23.
can be used to enable tamper on a wireless transmitter.
INSTANT WITH TAMPER ENABLED -
Armed LED is on. This zone type can be used to enable tamper on a wireless transmitter.
ENTRY/EXIT DELAY 2 WITH TAMPER ENABLED-
during exit delay will enable the Automatic Bypass or Instant mode if so programmed.
can be used to enable tamper on a wireless transmitter.
NX-8 Control
Page 21
NOTE: To “null” a zone, program the zone in “Partition Select” as zero (0) in all partitions and do not
use end-of-line resistors.
L LOCATION 25 - ZONES 1-8 ZONE TYPE (8 segments, numerical data)
Location 25 contains the Zone Type for zones 1-8. Segment 1 is for zone 1, and Segment 8 is for zone 8.
Default Zone Types are found in the table on page 20. To customize a Zone Type, see page 35.
Location 26 is used to select the partition(s) that zones 1 - 8 reside in. A zone may reside in any combination of the 8
partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions it resides in are armed. A zone that resides in more than 1 partition will be reported to its lowest partition number.
Location 26 has 8 segments. Segment 1 corresponds to zone 1, and Segment 8 corresponds to zone 8.
L LOCATION 27 - ZONES 9-16 ZONE TYPE (8 segments, numerical data)
Location 27 contains the Zone Type for zones 9 -16. Segment 1 is for zone 9, Segmen t 8 is for zon e 16. Defau lt
Zone Types are found in the table on page 20. To customize a Zone Type, see page 35.
Location 28 is used to select the partition(s) that zones 9-16 reside in. A zone may reside in any combination of the 8
partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Location 28 has 8
segments. Segment 1 corresponds to zone 9 and Segment 8 corresponds to zone 16.
L LOCATION 29 - ZONES 17-24 ZONE TYPE (8 segments, numerical data)
Location 29 contains the Zone Type for zones 17-24. Segment 1 is for zone 17, Segment 8 is for zone 24. Default
Zone Types are found in the table on page 20. To customize a Zone Type, see page 35.
Location 30 is used to select the partition(s) that zones 17-24 reside in. A zone may reside in any combination of the
8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Location 30 has 8
segments. Segment 1 corresponds to zone 17 and Segment 8 corresponds to zone 24.
L LOCATION 31 - ZONES 25-32 ZONE TYPE GROUP (8 segments, numerical data)
Location 31 contains the Zone Type for zones 25-32. Segment 1 is for zone 25, Segment 8 is for zone 32. Default
Zone Types are found in the table on page 20. To customize a Zone Type, see page 35.
Location 32 is used to select the partition(s) that zones 25-32 reside in. A zone may reside in any combination of the
8 partitions. If a burglary zone resides in more than 1 partition it will only be active when all partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 25 and Segment 8 corresponds to zone 32.
L LOCATION 33 - ZONES 33-40 ZONE TYPE (8 segments, numerical data)
Location 33 contains the Zone Type for zones 33-40. Segment 1 is for zone 33 Segment 8 is for zone 40. Default
Zone Types are found in the table on page 20. To customize a Zone Type, see page 35.
LOCATION 34 - PARTITION SELECT, ZONES 33-40 (8 segments of feature selection data)
Location 34 is used to select the partition(s) that zones 33-40 reside in. A zone may reside in any combination of the
8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 33 and Segment 8 corresponds to zone 40.
L LOCATION 35 - ZONES 41-48 ZONE TYPE (8 segments of numerical data)
Location 35 contains the Zone type for zones 41-48. Segment 1 is for zone 41 Segment 8 is for zone 48. Default
Zone Types are found in the table on page 20. To customize a Zone Type, see page 35.
Location 36 is used to select the partition or partitions that zones 41-48 reside in. A zone may reside in any
combination of the 8 partitions. If a burglary zone resides in more than 1 partition it will only be active when all
partitions are armed. A zone that resides in more than 1 partition, will be reported to its lowest partition.
Location 36 has 8 segments. Segment 1 corresponds to zone 41 and Segment 8 corresponds to zone 48.
L LOCATION 37 - SIREN AND SYSTEM SUPERVISION (5 segments, feature selection data)
Location 37 is used to enable various system feature and reporting options. (Refer to the feature definitions.)
Segment 1:1 - On if siren sounds for "Telephone Line Cut" when armed.
2 - On if siren sounds for "Telephone Line Cut" when disarmed.
3 - On if siren blast at arming.
4 - On if siren blast at exit expiration.
5 - On if siren blast at closing kissoff.
6 - On if siren sounds during a "Cross Zone" verification time.
7 - On if siren sounds for a Zone or Box Tamper.
8 - On if siren blasts 1 time for keyswitch or wireless arming; 2 times for disarming. (
be disabled for SIA CP-01 installations.
Segment 2:1 - On if siren driver should be a voltage output. Off if on board siren driver enabled.
2 - On if siren sounds for expander trouble (Required for UL installations).
3 - On for Immediate Restore by zone. Off for zones to restore only when siren is off.
4 - On if Dynamic Battery Test performed at arming. Off if performed at disarming. (See loc 40)
5 - On if Battery Missing Test is performed every 12 seconds.
6 - On if Manual Bell Test performed during [r]-[4] test function.
7 - On if Manual Communicator Test performed during [r]- [4] test function.
8 - On if Box Tamper terminals on the control panel are enabled.
Segment 3: 1 - On if Box Tamper report enabled.
2 - On if AC Fail reporting enabled.
3 - On if Low Battery reporting enabled.
4 - On if Aux. Power Overcurrent report enabled.
5 - On if Siren Supervision report enabled.
6 - On if Telephone Line Cut report enabled.
7 - On if Ground Fault Detection report enabled.
8 - On if Expander Trouble reporting enabled.
Segment 4:1 - On if Fail To Communicate report enabled.
2 - On if Log Full report enabled.
3 - On if Autotest report enabled.
4 - On if Start/End programming report enabled.
5 - On if End Download report enabled.
6 - On if Sensor Low Battery report enabled.
7 - On if Sensor Missing report enabled.
8 - Reserved.
Segment 5: 1 = On enable Lost Clock service light.
2 = On enables Zone Doubling (requires NX-200 Zone Doubling Kit).
3 = On disables On-Board 8 zones.
4 = On will allow two trips on same cross-zone to activate an alarm.
5 = On will not allow zones that are force armed to report bypass.
6 = Reserved.
7 = Use internal crystal for clock.
8 = Disable Temporal Siren on Fire. NOTE: Do NOT disable for UL listed systems
)
L LOCATION 38 - SWINGER SHUTDOWN COUNT
Location 38 contains the number of trips during an arming cycle that the NX-8 will allow before bypassing a zone. The
count determination is described in the feature definitions beginning on page 5. Factory default is 1.
.
L LOCATION 39 - KEYPAD SOUNDER CONTROL (1 segment, feature selection data)
NOTE: Must
.
Segment 1: 1 - On if keypad sounds for ATelephone Line Cut@ when the system is armed.
2 - On if keypad sounds for ATelephone Line Cut@ when disarmed.
3 - On if keypad sounds upon AC Power Failure.
4 - On if keypad sounds when a Low Battery is detected.
5 - On if keypad sounds during Cross Zone trip time.
6 - On if keypad sounds for zone and box tampers.
7 - Reserved.
8 - On if keypad sounds for expander trouble (required for UL installations).
NX-8 Control
23
Page 24
L LOCATION 40 - SYSTEM TIMERS (10 segments, numerical data)
Location 40 contains the duration of various system timing functions. Example: If you desire the duration of the
Dynamic Battery Test to be 30 minutes, you should program [3]-[0]-[r] in segment 1 of this location. The [3]-[0] is the
number of minutes, and the [r] stores the data and moves to the next segment of this location.
Segment 1 Dynamic Battery Test duration in minutes (0-255 minutes). Factory default is 0 = no test.
Segment 2 AC Fail report delay in minutes 0-255 minutes. Factory default is 5.
Segment 3 Power Up Delay in seconds (0-60 seconds). Factory default is 60.
Segment 4 Siren Time in minutes (1-254 minutes). Factory default is 8.
Segment 5 Telephone Line Cut delay in seconds (0-255 seconds). Factory default is 0 = no TLM.
Segment 6 Cross Zone time in minutes (0-255 minutes). Factory default is 5.
Segment 7 Chime time in 50 mS (1/20th second) increments from 0-12 seconds (0 = follows zone 255
latched). Factory default is 3.
Segment 8 Dialer delay in seconds (15-255 seconds). Factory default is 30.
Segment 9 Fire Alarm Verification time in seconds (120-255 seconds). Factory default is 0 = no fire alarm
verification. NOTE: This feature is not approved for residential use in California
Segment 10 Listen-In time in seconds (0-255 seconds). Factory default is 0 = no Listen-In time.
Note for UL LISTED SYSTEMS: The "Listen-In" feature cannot be enabled. The "Dynamic Battery Test"
feature cannot exceed four (4) hours. The dial delay shall be set to -0-.
LOCATION 41 - SPECIAL FEATURES (1 segment, feature selection data)
Segment 1:
1 - On enables the 6-digit code option. If 6-digit option is enabled, all arm/disarm codes and the "Go To
Program Code" are 6 digits. If this option is enabled, the default user 1 code is [1]-[2]-[3]-[4]-[5]-[6].
NOTE: IF YOU ENABLE THIS OPTION, VERIFY THAT THE "GO TO PROGRAM CODE" IS A
SIX-DIGIT CODE BEFORE EXITING PROGRAMMING.
2 - On requires code entry for [r]-[9]-[8] (perform call back download) and [r]-[9]-[9] (answer incoming
call for download) functions.
3 - Enable Auto Cancel / Abort (Refer to feature definitions beginning on page 5)
4 - Enable Walk-Test Mode (Refer to feature definitions beginning on page 5)
5-8 Reserved.
L LOCATION 42 - GO TO PROGRAM CODE (6 segments, numerical data)
Location 42 contains the "Go To Program Code". This location contains either a 4 or 6-digit code. If the 6-digit code
option is enabled in Location 41, THIS CODE MUST CONTAIN SIX (6) DIGITS. If this option is not enabled in
location 41, the last 2 segments (digits) will be ignored. With the NX-8 disarmed, the "Go To Program Code" can be
used to enter the Program Mode.
LOCATION 43 - GO TO PROGRAM CODE PARTITION AND AUTHORIZATION (2 segments, feature selection)
The "Go To Program Code" can be used as a standard arm/disarm code. When using the code to arm or disarm, the
user ID is 255. (This code may not be changed in the Run Mode.)
Segment 1:1 - Reserved.
2 - On enables "Go To Program Code" as an arm only code.
3 - On enables "Go To Program Code" as an arm only after closing.
4 - On enables "Go To Program Code" as a master arm/disarm code (can change user codes)
5 - On enables "Go To Program Code" as an arm/disarm code.
6 - On enables "Go To Program Code" to bypass zones.
7 - On enables "Go To Program Code" opening and closing reports.
8 - Reserved.
Segment 2:1 - On enables the "Go To Program Code" for Partition #1.
2 - On enables the "Go To Program Code" for Partition #2.
3 - On enables the "Go To Program Code" for Partition #3.
4 - On enables the "Go To Program Code" for Partition #4.
5 - On enables the "Go To Program Code" for Partition #5.
6 - On enables the "Go To Program Code" for Partition #6.
7 - On enables the "Go To Program Code" for Partition #7.
8 - On enables the "Go To Program Code" for Partition #8.
24
NX-8 Control
Page 25
L LOCATION 44 - DURESS CODE (6 segments, numerical data)
Location 44 contains the "Duress" code. This Location contains either 4 or 6 digits. If the 6-digit code option is
enabled in Location 41, THIS CODE MUST CONTAIN SIX (6) DIGITS. If the 6-digit option is not enabled in location
41, the last 2 digits will be ignored. If the duress code is programmed, it will work for all partitions.
Location 45 is used to select which partition(s) the events must occur in before the output will activate. Location 45
has 4 segments. Segment 1 corresponds to output 1, and Segment 4 corresponds to output 4.
Location 46 contains special timing feature activation for the four auxiliary outputs. Segment 1 corresponds to output
1, Segment 4 corresponds to output 4.
Segments 1 - 4:1 = On if output should be timed in minutes; Off if timed in seconds.
2 = On if output should latch; Off if output should be timed.
3 = On if output should stop timing upon code entry; Off if the output should continue to time
upon code entry.
4 = On if output should only activate between the closing and opening time in loc. 52 and 53.
5 = On if output should only activate between the opening and closing time in loc. 52 and 53.
6 = On if output should be inverted (0 volts going to 12 volts when activated).
7 = Reserved.
8 = Reserved.
LOCATION 47 - AUXILIARY OUTPUT #1, EVENT AND TIME (2 segments, numerical data)
Segment 1: Use Table 1 on page 26 to select the event that will activate Auxiliary Output 1.
Segment 2: Program the timing from 0-255 (minutes or seconds, depending on data programmed in
Segment 1, Location 46). Programming a "0" makes the output follow the event.
LOCATION 48 - AUXILIARY OUTPUT #2, EVENT AND TIME (2 segments, numerical data)
Segment 1: Use Table 1 on page 26 to select the event that will activate Auxiliary Output 2.
Segment 2: Program the timing from 0-255 (minutes or seconds, depending on data programmed in
Segment 2, Location 46). Programming a "0" makes the output follow the event.
LOCATION 49- AUXILIARY OUTPUT #3, EVENT AND TIME (2 segments, numerical data)
Segment 1: Use Table 1 on page 26 to select the event that will activate Auxiliary Output 3.
Segment 2: Program the timing from 0-255 (minutes or seconds, depending on data programmed in
Segment 3, Location 46). Programming a "0" makes the output follow the event.
LOCATION 50- AUXILIARY OUTPUT #4, EVENT AND TIME (2 segments, numerical data)
Segment 1: Use Table 1 on page 26 to select the event that will activate Auxiliary Output 4. .
Segment 2: Program the timing from 0-255 (minutes or seconds, depending on data programmed in
Segment 4, Location 46). Programming a "0" makes the output follow the event.
47
48 / Code Entry (See note below)
49 ˜ / Key FOB Function 1
50 ˜ / Key FOB Function 2
EVENT
Fire Trouble
Chime
Dynamic Battery Test Time
Open Period
Closed Period
Listen-In
Line Seizure
Ground Start
Fail To Communicate
Telephone Line Fault
Program Mode
Download In Process
Smoke Power
Short Circuit (Over-current)
Box Tamper
Siren Tamper
Any Open
Any Short
Any Fault (Open/ Short on Non-Fire Zone)
Beeping Keypad
˜Events 49 & 50 require NX-408E, NX-416E, or NX-448E wireless receivers to operate.
/ If set to follow condition, these events will be 1 second.
Notes : When Event 48 is programmed, it is possible to program a user code's authorization to select which output(s)
a particular code will activate. When LED 8 is on for an authorization, then LEDs 1- 4 correspond to that code
activating outputs 1 - 4 respectively. (See programming the LED keypads on page 9.)
26
NX-8 Control
Page 27
L LOCATION 51 - AUTOTEST CONTROL (4 segments, numerical data)
Segment 1:Program a "1" if the interval is to be in hours; Program a "0" if in days. Add a A2" to suppress
the daily test or a A3" to suppress the hourly test if any report has been sent.
Segment 2: Program the Autotest interval from 1-255 hours/days.
Segment 3: Program the Autotest report hour in 24-hour format (if the interval is in hours, this segment is
ignored).
Segment 4: Program the Autotest report time, number of minutes after the hour.
LOCATION 52 - OPENING TIME (2 segments, numerical data)
Location 52 contains the time in 24 hour format the NX-8 enables codes designated as arm only after closing. This
time is only valid on those days programmed in location 54. Note: Opening time must be earlier than closing time for
Auto Arm, Aux. Outputs, or Code Authorization to function properly.
Segment 1: Program the hour of the opening time.
Segment 2: Program the minutes after the hour of the opening time.
Location 53 contains the time in 24 hour format the NX-8 disables the disarm capability for codes designated as arm
only after closing. This is also the time the Automatic Arming sequence will begin (if enabled in location 55). Note:
Opening time must be earlier than closing time for Auto Arm, Aux. Outputs, or Code Authorization to function properly.
Segment 1: Program the hour of the closing / auto arm time.
Segment 2: Program the minutes after the hour of the closing / auto arm time.
LOCATION 54 - DAYS OF THE WEEK EACH PARTITION IS OPEN (8 Segments, feature selection data)
Location 54 selects which days of the week each partition is open. On these days, Aarm only after close window@
codes will be able to arm and disarm during open window. NOTE: If any partition is not programmed to be opened
and is programmed to Auto-Arm (Location 55), the NX-8 will try to arm every 45 minutes for the duration of the
closed period. On days not selected here, Aarm only after close window@ codes will not disarm. Segment 1 is for partition 1, and segment 8 is for partition 8. (See locations 52 and 53 for the opening and closing times for the
open days.)
Segment 1-8: 1 - Open on Sunday.
2 - Open on Monday.
3 - Open on Tuesday.
4 - Open on Wednesday.
5 - Open on Thursday.
6 - Open on Friday.
7 - Open on Saturday.
8 - Reserved.
LOCATION 55 - DAYS OF THE WEEK FOR AUTO ARMING IN PARTITIONS 1 THRU 8 (8 Segments, feature
selection data)
Location 55 selects which days each partition will auto arm. Segment 1 is for partition 1, and segment 8 is for partition
8. If a zone is faulted when the panel tries to auto arm, the zone will be bypassed.
Segments 1-8: 1 - Auto Arming on Sunday.
2 - Auto Arming on Monday.
3 - Auto Arming on Tuesday.
4 - Auto Arming on Wednesday.
5 - Auto Arming on Thursday.
6 - Auto Arming on Friday.
7 - Auto Arming on Saturday.
8 - Reserved.
NX-8 Control
27
Page 28
LOCATIONS 56- 83 ARE ONLY USED WHEN REPORTING EVENTS TO A PAGER OR USING A SLOW FORMAT
SUCH AS 4+2. WHEN USING CONTACT ID OR SIA, THERE IS NO NEED TO PROGRAM THESE LOCATIONS.
Location 56 contains the event code for any zone "Restore" for a 4+2 format. The digit programmed in this location will
be sent as the tens digit in place of the alarm event code. The zone ID will always be reported as the ones digit of the zone number (i.e. 9 for zone 29). This location contains 8 segments. Any segment left as "0" will follow the
Segment 1 selection.
Location 57 contains the event code for a zone "Bypass" for a 4+2 format. The digit programmed in this location will
be sent as the tens digit. The zone ID will always be reported as the ones digit of the zone number (i.e. 9 for
zone 29). This location contains 8 segments. Any segment left as "0" will follow the Segment 1 selection.
Location 58 contains the event code for a zone "Tamper" for a 4+2 format. The digit programmed in this location will
be sent as the tens digit. The zone ID will always be reported as the zone number(i.e. 9 for zone 29). Any
segment left as "0" will follow the Segment 1 selection.
LOCATION 59 - TROUBLE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical
data )
Location 59 contains the event code for a zone "Trouble" for a 4+2 format. The digit programmed in this location will
be sent as the tens digit. The zone ID will always be reported as the zone number(i.e. 9 for zone 29). Any
segment left as "0" will follow the event code for partition 1.
Location 60 contains the event code for a zone "Sensor Low Battery" for a 4+2 format. The digit programmed in this
location will be sent as the tens digit.. The zone ID will always be reported as the zone number(i.e. 9 for zone 29).
Any segment left as "0" will follow the Segment 1 selection.
Location 61 contains the event code for a zone "Sensor Missing" for a 4+2 format. The digit programmed in this
location will be sent as the tens digit.. The zone ID will always be reported as the zone number(i.e. 9 for zone 29).
Any segment left as "0" will follow the Segment 1 selection.
Location 62 contains the tens and ones digits that will be sent for a 4+2 format if the Duress code is enabled in
location 44. Segment 1 contains the tens digit, segment 2 contains the ones digit.
LOCATION 63 - KEYPAD AUXILIARY 1 COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments,
numerical data )
Location 63 contains the tens and ones digits that will be sent for a 4+2 format if the keypad "Auxiliary 1" (FIRE) is
enabled in the partition feature selection . Segment 1 contains the tens digit, segment 2 contains the ones digit.
Location 64 contains the tens and ones digits that will be sent for a 4+2 format if the keypad "Auxiliary 2" (MEDICAL)
is enabled in the partition feature selection. Segment 1 contains the tens digit, segment 2 contains the ones digit.
Location 65 contains the tens and ones digits that will be sent for a 4+2 format if the keypad "Panic" is enabled in the
partition feature selection Segment 1 contains the tens digit segment 2 contains the ones digit.
Location 66 contains the tens and ones digits that will be sent for a 4+2 format if the keypad "Multiple Code Entry"
(Tamper) is enabled in the partition feature selection. Segment 1 contains the tens digit, se gment 2 contai ns the ones
digit.
Location 67 contains the tens and ones digits that will be sent for a 4+2 format if the "Box Tamper" feature is enabled
in location 37. Segment 1 contains the tens digit of the "Box Tamper". Segment 2 contains the ones digit of the "Box
Tamper". Segment 3 contains the tens digit of the "Box Tamper Restore". Segment 4 contains the ones digit of the
"Box Tamper Restore".
LOCATION 68 - AC FAIL / AC FAIL RESTORE COMMUNICATOR CODES, SLOW SPEED FORM ATS ONLY
(4 segments, numerical data)
Location 68 contains the tens and ones digits for a 4+2 format that will be sent if "AC Fail Reporting" is enabled.
Segment 1 contains the tens digit of the "AC Fail Reporting". Segment 2 contains the ones digit of the "AC Fail
Reporting". Segment 3 contains the tens digit of the "AC Fail Restore". Segment 4 contains the ones digit of the "AC
Fail Restore".
Location 69 contains the tens and ones digits for a 4+2 format that will be sent if "Low Battery Reporting" is enabled..
Segment 1 contains the tens digit of the "Low Battery Reporting". Segment 2 contains the ones digit of the "Low
Battery Reporting". Segment 3 contains the tens digit of the "Low Battery Restore". Segment 4 contains the ones
digit of the "Low Battery Restore".
LOCATION 70 - AUX POWER OVERCURRENT/ AUX POWER OVERCURR ENT RESTORE COMMUNICAT OR
CODES, SLOW SPEED FORMATS ONLY (4 segments, numerical data)
Location 70 contains the tens and ones digits for a 4+2 format that will be sent if "Aux Power Overcurrent Reporting"
is enabled. Segment 1 contains the tens digit of the "Aux Power Overcurrent ReportIng". Segment 2 contains the
ones digit of the "Aux Power Overcurrent Reporting". Segment 3 contains the tens digit of the "Aux Power Overcurrent
Restore". Segment 4 contains the ones digit of the "Aux Power Overcurrent Restore".
LOCATION 71 - BELL TAMPER AND BELL TAMPER RESTORE COMMUNICATOR CODES, SLOW SPEED
FORMATS ONLY (4 segments, numerical data)
Location 71 contains the tens and ones digits for a 4+2 format that will be sent if siren supervision reporting is
enabled. Segment 1 contains the tens digit of the "Bell Tamper Reporting". Segment 2 contains the ones digit of the
"Bell Tamper Reporting". Segment 3 contains the tens digit of the "Bell Tamper Restore". Segment 4 contains the
ones digit of the "Bell Tamper Restore".
LOCATION 72 - TELEPHONE LINE CUT AND TELEPHONE LINE CUT RESTORE COMMUNICA TOR CODES,
SLOW SPEED FORMATS ONLY (4 segments, numerical data)
Location 72 contains the tens and ones digits for a 4+2 format that will be sent if "Telephone Line Cut Reporting" is
enabled. Segment 1 contains the tens digit of the "Telephone Line Cut Reporting". Segment 2 contains the ones digit
of the "Telephone Line Cut Reporting". Segment 3 contains the tens digit of the "Telephone Line Cut Restore".
Segment 4 contains the ones digit of the "Telephone Line Cut Restore".
LOCATION 73 - GROUND FAULT AND GROUND FAULT RESTORE COMMUNICATOR CODES, SLOW SPEED
FORMATS ONLY (4 segments, numerical data)
Location 73 contains the tens and ones digits for a 4+2 format that will be sent if "Ground Fault Reporting" is enabled,
and the NX-870 is installed. Segment 1 contains the tens digit of the "Ground Fault Reporting". Segment 2 contains
the ones digit of the "Ground Fault Reporting". Segment 3 contains the tens digit of the "Ground Fault Restore".
Segment 4 contains the ones digit of the "Ground Fault Restore".
30
NX-8 Control
Page 31
LOCATION 74 - EXPANDER TROUBLE AND EXPANDER TROUBLE RESTORE COMMUNICATOR COD ES,
SLOW SPEED FORMATS ONLY (4 segments, numerical data)
Location 74 contains the tens and ones digits for a 4+2 format that will be sent if "Expander Trouble Reporting" is
enabled. Segment 1 contains the tens digit of the "Expander Trouble Reporting". Segment 2 contains the ones digit
of the "Expander Trouble Reporting". Segment 3 contains the tens digit of the "Expander Trouble Restore". Segment
4 contains the ones digit of the "Expander Trouble Restore".
LOCATION 75 - FAIL TO COMMUNICATE COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY
(2 segments, numerical data)
Location 75 contains the tens and ones digits for a 4+2 format that will be sent if the "Fail To Communicate
Reporting" is enabled. Segment 1 contains the tens digit, segment 2 contains the ones digit.
LOCATION 76 - LOG FULL COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (2 segments, numerical
data)
Location 76 contains the tens and ones digits for a 4+2 format if the "Log Full Reporting" is enabled. Segment 1
contains the tens digit, segment 2 contains the ones digit.
LOCATION 77 - OPENING COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical
data)
Location 77 contains the tens digit of a 4+2 format if the "Opening Reporting" is enabled. The ones digit is the ones
digit of the user number that did the opening. If the user is greater than 9, the numbers will begin repeating. If
it is required to report openings and closings for more than 9 users, Contact ID or SIA format must be used. Any
segment left as "0" will follow the Segment 1 selection.
Segment 1 - Opening Code for Partition #1.
Segment 2 - Opening Code for Partition #2.
Segment 3 - Opening Code for Partition #3.
Segment 4 - Opening Code for Partition #4.
Segment 5 - Opening Code for Partition #5.
Segment 6 - Opening Code for Partition #6.
Segment 7 - Opening Code for Partition #7.
Segment 8 - Opening Code for Partition #8.
LOCATION 78 - CLOSING COMMUNICATOR CODE, SLOW SPEED FORMATS ONLY (8 segments, numerical
data)
Location 78 contains the tens digit of a 4+2 format if the "Closing Reporting" is enabled. The ones digit is the ones
digit of the user number that did the closing. If the user is greater than 9, the numbers will begin repeating. If
it is required to report openings and closings for more than 9 users, Contact ID or SIA format must be used. Any
segment left as "0" will follow the Segment 1 selection.
Segment 1 - Closing Code for Partition #1.
Segment 2 - Closing Code for Partition #2.
Segment 3 - Closing Code for Partition #3.
Segment 4 - Closing Code for Partition #4.
Segment 5 - Closing Code for Partition #5.
Segment 6 - Closing Code for Partition #6.
Segment 7 - Closing Code for Partition #7.
Segment 8 - Closing Code for Partition #8.
Location 79 contains the tens and ones digits for a 4+2 format that will be sent if the "Autotest" or "Manual Test" is
enabled. Segment 1 contains the tens digit segment 2 contains the ones digit.
LOCATION 80 - RECENT CLOSING AND EXIT ERROR COMMUNICATOR CODE, SLOW SPEED FORMATS
ONLY (2 segments, numerical data)
Location 80 contains the tens digit for a 4+2 format that will be sent if "Recent Closing" and/or "Exit Error Reporting" is
enabled. Segment 1 contains the tens digit for the "Recent Closing Reporting". Segment 2 contains the digit for the
"Exit Error Reporting". The ones digit is the ones digit of the user who closed. If the user number is greater than 9, the numbers will begin repeating(i.e. 9 for user 29). If it is required to report Recent Closings and Exit
Errors for more than 9 users, Contact ID or SIA format must be used.
NX-8 Control
31
Page 32
LOCATION 81 - START PROGRAM AND END PROGRAM COMMUNICATOR CODES, SLOW SPEED FORMATS
ONLY (4 segments, numerical data)
Location 81 contains the tens and ones digits for a 4+2 format that will be sent if "Start / End Programming Reporting"
is enabled. Segment 1 contains the tens digit of the "Start Program Reporting". Segment 2 contains the ones digit of
the "Start Program Reporting". Segment 3 contains the tens digit of the "End Program Reporting". Segment 4
contains the ones digit of the "End Program Reporting".
LOCATION 82 - END DOWNLOAD COMMUNICATOR CODE, SLOW SPEED FORM ATS ONLY (4 segments,
numerical data)
Location 82 contains the tens and ones digits for a 4+2 format that will be sent if "End Downloading Reporting" is
enabled. Segment 1 and 2 are reserved. Segment 3 contains the tens digit of the "End Download Reporting".
Segment 4 contains the ones digit of the "End Download Reporting". Note: A start download report will be sent to the
internal event log.
Location 83 contains the tens digit for a 4+2 format that will be sent if "Cancel Reporting" is enabled. Segment 1
contains the tens digit for the "Cancel Communicator Reporting". The ones digit is the ones digit of the user who canceled. If the user number is greater than 9, the numbers will begin repeating (i.e. 9 for user 29). If it is
required to report Cancels for more than 9 users, Contact ID or SIA format must be used.
LOCATIONS 84-87 RESERVED.
*** LOCATIONS 88-109 ARE FOR PROGRAMMING DIFFERENT ACCOUNT CODES AND/OR ***
*** FEATURES FOR EACH PARTITION. IF A LOCATION IS LEFT UNPROGRAMMED, THE ***
** FEATURE FOR PARTITION 1 AND ACCOUNT CODE FOR THE PHONE NUMBER WILL BE USED **
LOCATION 88 - ACCOUNT CODE FOR PARTITION 1 (6 segments, numerical data)
Location 88 contains the account code sent when partition 1 is reported. If location 88 is left unprogrammed (all
A10"s), then the account code corresponding to the Phone number dialed will be used. If the account code is
less than six digits, program a A10" in the segment immediately after the last digit of the account code. If the account
code is 6 digits long, program all 6 segments.
LOCATION 89 - ACCOUNT CODE FOR PARTITION 2 (6 segments, numerical data)
Location 89 contains the account code sent when partition 2 is reported. If location 89 is left unprogrammed (all
A10"s), then the account code corresponding to the Phone number dialed will be used. If the account code is
less than six digits, program a A10" in the segment immediately after the last digit of the account code. If the account
code is 6 digits long program all 6 segments.
Location 90 is used to enable certain features that can be accessed or are visible to the user from the keypad of the
system. In addition, certain communicator reports are enabled in this location. Each of these features can be
enabled by partition. This location contains 3 segments, with eight possible features per segment. Refer to Location
23, Segments 1,2, and 3 (page 19) for the feature selections. If all segments are blank (nothing enabled), the
features for partition 1 will be used.
LOCATION 91 - PARTITION 2 ENTRY EXIT TIMERS (4 segments, numerical data)
Location 91 is used to enter in seconds the Entry and Exit times. There are 2 separate entry and exit times. Valid
entries are 10-255 seconds. If all segments are A0", the entry and exit times for partition 1 will be used.
Segment 1, Entry time 1: Entry time that will be used when a Delay 1 zone type initiates an entry delay.
Segment 2, Exit time 1: Exit time that will be used for all zones designated as Delay 1.
Segment 3, Entry time 2: Entry time that will be used when a Delay 2 zone type initiates an entry delay.
Segment 4, Exit time 2: Exit time that will be used for all zones designated as Delay 2.
LOCATION 92 - ACCOUNT CODE FOR PARTITION 3 (6 segments, numerical data)
The account code sent when partition 3 is reported is programmed in location 92. If location 92 is left
unprogrammed (all A10" ) then the account code corresponding to the Phone number dialed will be used. If
the account code is less than six digits, program a A10" in the segment immediately after the last digit of the account
code. If the account code is 6 digits long program all 6 segments.
Location 93 is used to enable certain features that can be accessed or are visible to the user from the keypad of the
system. In addition, certain communicator reports are enabled in this location. Each of these features can be enabled
by partition. This location contains 3 segments, with eight possible features per segment. Refer to Location 23,
Segments 1, 2, and 3 (page 19) for the feature selections. If all segments are blank (nothing enabled), the features
for partition 1 will be used.
LOCATION 94 - PARTITION 3 ENTRY EXIT TIMERS (4 segments, numerical data)
Location 94 is used to enter in seconds the Entry and Exit times. There are 2 separate entry and exit times. Valid
entries are 10-255 seconds. If all segments are A0", the entry and exit times for partition 1 will be used.
Segment 1, Entry time 1: Entry time that will be used when a Delay 1 zone type initiates an entry delay.
Segment 2, Exit time 1: Exit time that will be used for all zones designated as Delay 1.
Segment 3, Entry time 2: Entry time that will be used when a Delay 2 zone type initiates an entry delay.
Segment 4, Exit time 2: Exit time that will be used for all zones designated as Delay 2.
LOCATION 95 - ACCOUNT CODE FOR PARTITION 4 (6 segments, numerical data)
The account code sent when partition 4 is reported is programmed in location 95. If location 95 is left
unprogrammed (a ll A10" ) then the account code corresponding to the Phone number dialed will be used. If the
account code is less than six digits, program a A10" in the segment immediately after the last digit of the account code.
If the account code is 6 digits long, program all 6 segments.
Location 96 is used to enable certain features that can be accessed or are visible to the user from the keypad of the
system. In addition, certain communicator reports are enabled in this location. Each of these features can be
enabled by partition. This location contains 3 segments, with eight possible features per segment. Refer to Location
23, Segments 1,2, and 3 (page 19) for the feature selections. If all segments are blank (nothing enabled), the
features for partition 1 will be used.
LOCATION 97 - PARTITION 4 ENTRY EXIT TIMERS (4 segments, numerical data)
Location 97 is used to enter in seconds the Entry and exit times. There are 2 separate entry and exit times. Valid
entries are 10-255 seconds. If all segments are A0", the entry and exit times for partition 1 will be used.
Segment 1, Entry time 1: Entry time that will be used when a Delay 1 zone type initiates an entry delay.
Segment 2, Exit time 1: Exit time that will be used for all zones designated as Delay 1.
Segment 3, Entry time 2: Entry time that will be used when a Delay 2 zone type initiates an entry delay.
Segment 4, Exit time 2: Exit time that will be used for all zones designated as Delay 2.
LOCATION 98 - ACCOUNT CODE FOR PARTITION 5 (6 segments, numerical data)
The account code sent when partition 5 is reported is programmed in location 98. If location 98 is left
unprogrammed (a ll A10" ) then the account code corresponding to the Phone number dialed will be used. If the
account code is less than six digits, program a A10" in the segment immediately after the last digit of the account code.
If the account code is 6 digits long, program all 6 segments.
Location 99 is used to enable certain features that can be accessed or are visible to the user from the keypad of the
system. In addition, certain communicator reports are enabled in this location. Each of these features can be enabled
by partition. This location contains 3 segments, with eight possible features per segment. Refer to Location 23,
Segments 1,2, and 3 (page 19) for the feature selec tions. If all segments are blank (nothing enabled), the features
for partition 1 will be used.
LOCATION 100 - PARTITION 5 ENTRY EXIT TIMERS (4 segments, numerical data)
Location 100 is used to enter in seconds the Entry and exit times. There are 2 separate entry and exit times. Valid
entries are 10-255 seconds. If all segments are A0", the entry and exit times for partition 1 will be used.
Segment 1, Entry Time 1: Entry time that will be used when a delay 1 zone type initiates an entry delay.
Segment 2, Exit Time 1: Exit time that will be used for all zones designated as delay 1.
Segment 3, Entry Time 2: Entry time that will be used when a delay 2 zone type initiates an entry delay.
Segment 4, Exit Time 2: Exit time that will be used for all zones designated as delay 2.
NX-8 Control
33
Page 34
LOCATION 101 - ACCOUNT CODE FOR PARTITION 6 (6 segments, numerical data)
The account code sent when partition 6 is reported is programmed in location 101. If location 101 is left
unprogrammed (all A10" ) then the account code corresponding to the Phone number dialed will be used.
Program the account code is less than six digits, program a A10" in the segment immediately after the last digit of the
account code. If the account code is 6 digits long, program all 6 segments.
Location 102 is used to enable certain features that can be accessed or are visible to the user from the keypad of the
system. In addition, certain communicator reports are enabled in this location. Each of these features can be
enabled by partition. This location contains 3 segments, with eight possible features per segment. Refer to Location
23, Segments 1, 2, and 3 (page 19) for the feature selections. If all segments are blank (nothing enabled), the
features for partition 1 will be used.
LOCATION 103 - PARTITION 6 ENTRY EXIT TIMERS (4 segments, numerical data)
Location 103 is used to enter in seconds the Entry and Exit times. There are 2 separate entry and exit times. Valid
entries are 10-255 seconds. If all segments are A0", the entry and exit times for partition 1 will be used.
Segment 1, Entry Time 1: Entry time that will be used when a Delay 1 zone type initiates an entry delay.
Segment 2, Exit Time 1: Exit time that will be used for all zones designated as Delay 1.
Segment 3, Entry Time 2: Entry time that will be used when a Delay 2 zone type initiates an entry delay.
Segment 4, Exit Time 2: Exit time that will be used for all zones designated as Delay 2.
LOCATION 104 - ACCOUNT CODE FOR PARTITION 7 (6 segments, numerical data)
The account code sent when partition 7 is reported is programmed in location 104. If location 104 is left
unprogrammed (a ll A10" ) then the account code corresponding to the Phone number dialed will be used. If the
account code is less than six digits, program a A10" in the segment immediately after the last digit of the account code.
If the account code is 6 digits long, program all 6 segments.
Location 105 is used to enable certain features that can be accessed or are visible to the user from the keypad of the
system. In addition, certain communicator reports are enabled in this location. Each of these features can be
enabled by partition. This location contains 3 segments, with eight possible features per segment. Refer to Location
23, Segments 1,2, and 3 (page 19) for the feature selections. If all segments are blank (nothing enabled), the
features for partition 1 will be used.
LOCATION 106 - PARTITION 7 ENTRY EXIT TIMERS (4 segments, numerical data)
Location 106 is used to enter in seconds the Entry and Exit times. There are 2 separate entry and exit times. Valid
entries are 10-255 seconds. If all segments are A0", the entry and exit times for partition 1 will be used.
Segment 1, Entry Time 1: Entry time that will be used when a Delay 1 zone type initiates an entry delay.
Segment 2, Exit Time 1: Exit time that will be used for all zones designated as Delay 1.
Segment 3, Entry Time 2: Entry time that will be used when a Delay 2 zone type initiates an entry delay.
Segment 4, Exit Time 2: Exit time that will be used for all zones designated as Delay 2.
LOCATION 107 - ACCOUNT CODE FOR PARTITION 8 (6 segments, numerical data)
The account code sent when partition 8 is reported is programmed in location 107. If location 107 is left
unprogrammed (a ll A10" ) then the account code corresponding to the Phone number dialed will be used. If the
account code is less than six digits, program a A10" in the segment immediately after the last digit of the account code.
If the account code is 6 digits long, program all 6 segments.
Location 108 is used to enable certain features that can be accessed or are visible to the user from the keypad of the
system. In addition, certain communicator reports are enabled in this location. Each of these features can be
enabled by partition. This location contains 3 segments, with eight possible features per segment. Refer to Location
23, Segments 1,2, and 3 (page 19) for the feature selections. If all segments are blank (nothing enabled), the
Location 109 is used to enter in seconds the Entry and Exit times. There are 2 separate entry and exit times. Valid
entries are 10-255 seconds. If all segments are A0", the entry and exit times for partition 1 will be used.
Segment 1, Entry Time 1: Entry time that will be used when a Delay 1 zone type initiates an entry delay.
Segment 2, Exit Time 1: Exit time that will be used for all zones designated as Delay 1.
Segment 3, Entry Time 2: Entry time that will be used when a Delay 2 zone type initiates an entry Delay.
Segment 4, Exit Time 2: Exit time that will be used for all zones designated as Delay 2.
LOCATIONS 110-149 ARE USED TO CHANGE THE ZONE TYPES (Configurations) AS LISTED IN THE TABLE
ON PAGE 20. THESE LOCATIONS ARE CONSIDERED ADVANCED PROGRAMMING A ND SHOULD
ONLY BE CHANGED WITH A THOROUGH UNDERSTANDING OF THE OPERATION OF EACH BIT.
LOCATION 110 - ZONE TYPE 1 ALARM EVENT CODE (1 segment, numerical data)
Location 110 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2 the digit in location 110 should be from 1-
15.The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 111 - ZONE TYPE 1 CHARACTERISTIC SELECT (3 segments, feature selection data)
Segment 1: 1 = Fire (turn on if this is a fire zone).
2 = 24 hour (turn on for non-fire 24 hour zones).
3 = Keyswitch zone. (normally open switch)
4 = Follower (turn on for burglary zones that are Instant during non-entry times).
5 = Delay 1 zone (follows timer 1 entry and exit times).
6 = Delay 2 zone (follows timer 2 entry and exit times).
7 = Interior (turn on if this zone should Automatically Bypass or Bypass for Stay Arming).
8 = Local only (turn on if this zone should not be reported).
Segment 2:1 = On if Zone Type will beep the keypad for alarm.
2 = On if Zone Type will sound the yelping siren for alarm.
3 = On if Zone Type will sound the temporal siren for alarm.
4 = On if Zone Type will chime.
5 = On if Zone Type can be bypassed.
6 = On if Zone Type is included in the group shunt.
7 = On if Zone Type is force armable.
8 = On if Zone Type is entry guard.
Segment 3:1 = On enables Fast Loop Response. (50mS)- Off= 500mS
2 = On enables Double End Of Line Tamper zone. (Mainly used for tamper on wireless zones)
3 = On enables Trouble Reporting zone. (Day zone and Fire zones)
4 = On if Zone Type is a Cross Zone.
5 = On enables Dialer Delay zone. (See location 40, page 24)
6 = On if Zone Type will swinger shutdown. (See location 38, page 23)
7 = On enables Restore reporting.
8 = On enables Listen-In. (See location 40, page 24)
LOCATION 112 - ZONE TYPE 2 ALARM EVENT CODE (1 segment, numerical data)
Location 112 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the numbe r
programmed in this location will be sent as the tens digit. When using 4+2 the digit in location 112 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 113 - ZONE TYPE 2 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 114 - ZONE TYPE 3 ALARM EVENT CODE (1 segment, numerical data)
Location 114 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 114 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
NX-8 Control
35
Page 36
LOCATION 115 - ZONE TYPE 3 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 116 - ZONE TYPE 4 ALARM EVENT CODE (1 segment, numerical data)
Location 116 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2 the digit in location 116 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 117 - ZONE TYPE 4 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 118 - ZONE TYPE 5 ALARM EVENT CODE (1 segment, numerical data)
Location 118 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 118 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 119 - ZONE TYPE 5 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 120 - ZONE TYPE 6 ALARM EVENT CODE (1 segment, numerical data)
Location 120 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2 the digit in location 120 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 121 - ZONE TYPE 6 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 122 - ZONE TYPE 7 ALARM EVENT CODE (1 segment, numerical data)
Location 122 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53.The zone ID will be that zone that is in alarm. If 4 +2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 122 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 123 - ZONE TYPE 7 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 124 - ZONE TYPE 8 ALARM EVENT CODE (1 segment, numerical data)
Location 124 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 124 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 125 - ZONE TYPE 8 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 126 - ZONE TYPE 9 ALARM EVENT CODE (1 segment, numerical data)
Location 126 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 126 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 127 - ZONE TYPE 9 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 128 - ZONE TYPE 10 ALARM EVENT CODE (1 segment, numerical data)
Location 128 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 128 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
36
NX-8 Control
Page 37
LOCATION 129 - ZONE TYPE 10 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 130 - ZONE TYPE 11 ALARM EVENT CODE (1 segment, numerical data)
Location 130 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 130 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 131 - ZONE TYPE 11 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 132 - ZONE TYPE 12 ALARM EVENT CODE (1 segment, numerical data)
Location 132 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53.The zone ID will be that zone that is in alarm. If 4 +2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 132 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 133 - ZONE TYPE 12 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 134 - ZONE TYPE 13 ALARM EVENT CODE (1 segment, numerical data)
Location 134 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 134 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 135 - ZONE TYPE 13 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 136 - ZONE TYPE 14 ALARM EVENT CODE (1 segment, numerical data)
Location 136 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 136 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 137 - ZONE TYPE 14 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 138 - ZONE TYPE 15 ALARM EVENT CODE (1 segment, numerical data)
Location 138 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 138 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 139 - ZONE TYPE 15 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 140 - ZONE TYPE 16 ALARM EVENT CODE (1 segment, numerical data)
Location 140 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 140 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 141 - ZONE TYPE 16 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
NX-8 Control
37
Page 38
LOCATION 142 - ZONE TYPE 17 ALARM EVENT CODE (1 segment, numerical data)
Location 142 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the
list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number programmed in this
location will be sent as the tens digit. When using 4+2, the digit in location 142 should be from 1-15. The zone ID for 4+2
formats will be the ones digit of the zone that is in alarm.
LOCATION 143 - ZONE TYPE 17 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 144 - ZONE TYPE 18 ALARM EVENT CODE (1 segment, numerical data)
Location 144 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the
list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number programmed in this
location will be sent as the tens digit. When using 4+2, the digit in location 144 should be from 1-15. The zone ID for 4+2
formats will be the ones digit of the zone that is in alarm.
LOCATION 145 - ZONE TYPE 18 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 146 - ZONE TYPE 19 ALARM EVENT CODE (1 segment, numerical data)
Location 146 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the
list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number programmed in this
location will be sent as the tens digit. When using 4+2, the digit in location 146 should be from 1-15. The zone ID for 4+2
formats will be the ones digit of the zone that is in alarm.
LOCATION 147 - ZONE TYPE 19 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
LOCATION 148 - ZONE TYPE 20 ALARM EVENT CODE (1 segment, numerical data)
Location 148 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the
list on page 53. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number programmed in this
location will be sent as the tens digit. When using 4+2, the digit in location 148 should be from 1-15. The zone ID for 4+2
formats will be the ones digit of the zone that is in alarm.
LOCATION 149 - ZONE TYPE 20 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 35.
38
NX-8 Control
Page 39
NX-8 PROGRAMMING WORKSHEETS
L
7
3
(Factory defaults for segments are in bold italics text and "Quick Start" locations are identified with the L symbol.)
Siren sounds for telephone line cut while disarmed.
2
Siren blast at arming.
3
Siren blast at exit delay expiration.
4
Siren blast at closing kissoff.
5
Siren sounds during a cross zone verification time.
6
Siren sounds for a tamper.
7
Siren blast one time for keyswitch arming, two times for disarming.
8
Convert siren driver to voltage out.
Siren sounds for expander trouble (required for U.L.).
2
Immediate Restore by zone.
3
Dynamic battery test performed upon arming.
4
Battery missing test performed every 12 seconds.
5
Manual bell test performed during [r]-[4] test function.
6
Manual communicator test performed during [r]-[4] test function.
7
Box tamper enabled.
8
DESCRIPTION
1
1
2
3
4
5
6
7
8
1
1
2
3
4
5
6
7
8
1
1
2
3
4
5
6
7
8
2
1
2
3
4
5
6
7
8
2
1
2
3
4
5
6
7
8
2
1
2
3
4
5
6
7
8
DEFAULT
3
1
2
3
4
5
6
7
8
4
1
2
3
4
5
6
7
8
5
1
2
3
4
5
6
7
8
6-6-6-6-6-6-6-6
3
1
2
3
4
5
6
7
8
4
1
2
3
4
5
6
7
8
5
1
2
3
4
5
6
7
8
6-6-6-6-6-6-6-6
3
1
2
3
4
5
6
7
8
4
1
2
3
4
5
6
7
8
5
1
2
3
4
5
6
7
8
PROGRAMMING DATA
6
1
2
3
4
5
6
7
8
7
1
2
3
4
5
6
7
8
_ _ _ _ _ _ _ _
6
1
2
3
4
5
6
7
8
7
1
2
3
4
5
6
7
8
_ _ _ _ _ _ _ _
6
1
2
3
4
5
6
7
8
7
1
2
3
4
5
6
7
8
8
1
2
3
4
5
6
7
8
8
1
2
3
4
5
6
7
8
8
1
2
3
4
5
6
7
8
42
NX-8 Control
Page 43
LOC PG
37 23
L
1
1
38 23 SWINGER SHUTDOWN COUNT
L
39 23
L
40
L
Segment #3 (Circle numbers to program)
2
3
4
5
6
7
8
Segment #4 (Circle numbers to program)
2
3
4
5
6
7
8
Segment #5 (Circle numbers to program)
1
2
3
4
5
6
7
8
KEYPAD SOUNDER CONTROL
Segment #1 (Circle numbers to program)
1
2
3
4
5
6
7
8
24
SYSTEM TIMERS
Segment #1 Dynamic Battery Test duration (0-255 minutes)
Segment #2 AC Failure report delay (0-255 minutes)
Segment #3 Power Up Delay (0-60 seconds)
Segment #4 Siren Time (1-254 minutes)
Segment #5 Telephone Line Cut delay (0-255 seconds)
Segment #6 Cross Zone Time (0-255 minutes)
Segment #7 Chime Time in 50 mS increments (0-255)
Segment #8 Dialer delay (15-255 seconds)
Segment #9 Fire Alarm Verification Time (120-255 sec.)
Segment #10 Listen-In Time (0-255 seconds)
DESCRIPTION
Box Tamper report enabled.
AC Fail report enabled.
Low Battery report enabled.
Auxiliary power over current report enabled.
Siren supervision report enabled.
Telephone Line Cut report enabled.
Ground Fault Detection report enabled.
Expander trouble report enabled.
Failure To Communicate report enabled.
Log Full report enabled.
Autotest report enabled.
Start and End Programming report enabled.
End Download report enabled.
Sensor Low Battery report enabled.
Sensor Missing report enabled.
Reserved.
Lost Clock service LED enable.
Zone Doubling enable.
Disable on-board eight zones.
Enables two trips on the same cross-zone to activate the alarm.
Disables bypass reports for force armed zones
Reserved.
Clock uses internal crystal.
Disable Temporal Siren on Fire (Do not disable on UL listed systems)
Keypad sounds for Telephone Line Cut when in the Armed state.
Keypad sounds for Telephone Line Cut when in the Disarmed state.
Keypad sounds upon AC Power Failure.
Keypad sounds upon Low Battery Detection.
Keypad sounds during Cross Zone Trip Time.
Keypad sounds for Tamper Alarm.
Reserved.
Keypad sounds for expander trouble (required for UL).
DEFAULT
1
0
5
60
8
0
5
3
30
0
0
DATA
_
_
_
_
_
_
_
_
_
_
_
NX-8 Control
43
Page 44
LOC PG
41 24
42 24 GO TO PROGRAM CODE
L
43 24
L
44
45
46 25 AUXILIARY OUTPUTS 1-4 SPECIAL TIMING
SPECIAL FEATURES
Segment #1 (Circle numbers to program)
Enables six digit code option. All arm/disarm/Go To Program codes require six digits
1
Requires valid user code entry for [r]-[9]-[8] and [r]-[9]-[9] functions to work.
2
Enable Auto Cancel / Abort.
3
Enable Walk-Test Mode.
4
Reserved.
5
Reserved.
6
Reserved.
7
Reserved.
8
GO TO PROGRAM CODE PARTITION AND AUTHORIZATION
Segment #1 (Circle numbers to program)
Reserved.
1
Enables "Go To Program Code" as an arm only code.
2
Enables "Go To Program Code" as an arm only after closing.
3
Enables "Go To Program Code" as a master arm/disarm code (can change user codes)
4
Enables "Go To Program Code" as an arm/disarm code.
5
Enables "Go To Program Code" to bypass zones.
6
Enables "Go To Program Code" opening and closing reports.
Auxiliary output to latch.
Auxiliary output to stop timing upon user code entry.
Auxiliary output to activate only between closing and opening time.
Auxiliary output to activate only between opening and closing time.
Invert auxiliary output ( 0 volts going to 12 volts when activated).
Reserved
Reserved
DESCRIPTION
1
1
2
3
4
5
6
7
8
2
1
2
3
4
5
6
7
8
DEFAULT
9-7-1-3-0-0
15-15-15-15-15-15
3
1
2
3
4
5
6
7
8
4
1
2
3
4
5
6
7
8
1
1
2
3
4
5
6
7
8
DATA
_ _ _ _ _ _
_ _ _ _ _ _
2
1
2
3
4
5
6
7
8
3
1
2
3
4
5
6
7
8
4
1
2
3
4
5
6
7
8
44
NX-8 Control
Page 45
Program a "1" if the interval is hours, a "0" if in
uppress the
255 days or
Program the autotest report time, minutes after the
LOC PG
47
48
49
50
51
L
52
53 27
25
25
25
25
27
27
54 27
55 27
DESCRIPTION
AUXILIARY OUTPUT #1, EVENT & TIME
Segment #1: Program the event number for output #1 here.
Segment #2: Program the timing for output #1 here .
AUXILIARY OUTPUT #2, EVENT & TIME
Segment #1: Program the event number for output #2 here.
Segment #2: Program the timing for output #2 here .
AUXILIARY OUTPUT #3, EVENT & TIME
Segment #1: Program the event number for output #3 here.
Segment #2: Program the timing for output #3 here .
AUXILIARY OUTPUT #4, EVENT & TIME
Segment #1: Program the event number for output #4 here.
Segment #2: Program the timing for output #4 here .
AUTOTEST CONTROL
DEFAULT
0=Burglary alarm
10 seconds
1=Fire alarm
10 seconds
2= 24 Hour Alarm
10 seconds
21-Armed State
0=Follow condition
Segment #1:
days. Add a A2" to suppress the daily test or a A3" to s
hourly test.
Segment #2: Program the autotest interval from 1hours.
Segment #3: Program the autotest report in 24 hour time format.
24
Segment #4:
hour.
OPENING TIME
Segment #1: Program the hour of the opening time.
Segment #2: Program the minutes after the hour of the
opening time.
CLOSING TIME / AUTO ARMING TIME
Segment #1: Program the hour of the closing time / auto
arming time.
20
Segment #2: Program the minutes after hour of closing / auto
arming time.
LED Extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC Power/Low Battery sounder alert
Enables Bypass toggle
Enables Silent Auto Arm
Enables Automatic Instant
Reserved
10-10-10-10-10-10 _ _ _ _ _ _
Segment #2
LED Extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC Power/Low Battery sounder alert
Enables Bypass toggle
Enables Silent Auto Arm
Enables Automatic Instant
Reserved
10-10-10-10-10-10 _ _ _ _ _ _
LED Extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC Power/Low Battery sounder alert
Enables Bypass toggle
Enables Silent Auto Arm
Enables Automatic Instant
Reserved
10-10-10-10-10-10 _ _ _ _ _ _
0-0-0-0
Segment #3
Open/Close
1
Bypass
2
Restore
3
Trouble
4
Tamper
5
Cancel
6
Recent Closing
7
Exit Error
8
0
0
0
0
Segment #3
Open/Close
1
Bypass
2
Restore
3
Trouble
4
Tamper
5
Cancel
6
Recent Closing
7
Exit Error
8
0
0
0
0
Segment #3
Open/Close
1
Bypass
2
Restore
3
Trouble
4
Tamper
5
Cancel
6
Recent Closing
7
Exit Error
8
0
0
0
0
RESERVED
_
_
_
_
_
_
_
_
_
_
_
_
48
NX-8 Control
Page 49
LOC PG
99 33
PARTITION 5, FEATURE AND REPORTING SELECTION
Segment #1
Quick Arm
1
Re-Exit
2
Auto Bypass
3
Silent Panic
4
Audible Panic
5
Auxiliary 1
6
Auxiliary 2
7
Multi Keypress Tamper
8
100
101 34 PARTITION 6, ACCOUNT CODE
102 34
33
PARTITION 5, ENTRY/EXIT TIMERS Segment #1 (Entry Time #1)
Segment #2 (Exit Time #1)
Segment #3 (Entry Time #2)
Segment #4 (Exit Time #2)
PARTITION 6, FEATURE AND REPORTING SELECTION
Segment #1
Quick Arm
1
Re-Exit
2
Auto Bypass
3
Silent Panic
4
Audible Panic
5
Auxiliary 1
6
Auxiliary 2
7
Multi Keypress Tamper
8
103
104 34 PARTITION 7, ACCOUNT CODE
105 34
34
PARTITION 6, ENTRY/EXIT TIMERS Segment #1 (Entry Time #1)
Segment #2 (Exit Time #1)
Segment #3 (Entry Time #2)
Segment #4 (Exit Time #2)
PARTITION 7, FEATURE AND REPORTING SELECTION
Segment #1
Quick Arm
1
Re-Exit
2
Auto Bypass
3
Silent Panic
4
Audible Panic
5
Auxiliary 1
6
Auxiliary 2
7
Multi Keypress Tamper
8
106
PARTITION 7, ENTRY/EXIT TIMERS
34
Segment #1 (Entry Time #1)
Segment #2 (Exit Time #1)
Segment #3 (Entry Time #2)
Segment #4 (Exit Time #2)
DESCRIPTION DEFAULT DATA
Segment #2
Segment #2
Segment #2
107 34 PARTITION 8, ACCOUNT CODE
LED Extinguish enable
1
Require user code for bypassing zones
2
Bypass sounder alert
3
AC Power/Low Battery sounder alert
4
Enables Bypass toggle
5
Enables Silent Auto Arm
6
Enables Automatic Instant
7
Reserved
8
LED Extinguish enable
1
Require user code for bypassing zones
2
3
Bypass sounder alert
4
AC Power/Low Battery sounder alert
5
Enables Bypass toggle
6
Enables Silent Auto Arm
7
Enables Automatic Instant
8
Reserved
LED Extinguish enable
1
Require user code for bypassing zones
2
3
Bypass sounder alert
4
AC Power/Low Battery sounder alert
5
Enables Bypass toggle
6
Enables Silent Auto Arm
7
Enables Automatic Instant
8
Reserved
Segment #3
Open/Close
1
Bypass
2
Restore
3
Trouble
4
Tamper
5
Cancel
6
Recent Closing
7
Exit Error
8
0
0
0
0
_
_
_
_
10-10-10-10-10-10 _ _ _ _ _ _
Segment #3
Open/Close
1
Bypass
2
Restore
3
Trouble
4
Tamper
5
Cancel
6
Recent Closing
7
Exit Error
8
0
0
0
0
_
_
_
_
10-10-10-10-10-10 _ _ _ _ _ _
Segment #3
Open/Close
1
Bypass
2
Restore
3
Trouble
4
Tamper
5
Cancel
6
Recent Closing
7
Exit Error
8
0
0
0
0
_
_
_
_
10-10-10-10-10-10 _ _ _ _ _ _
NX-8 Control
49
Page 50
LOC PG
108 34
PARTITION 8, FEATURE AND REPORTING SELECTION
DESCRIPTION DEFAULT DATA
Segment #1 Segment #2 Segment #3
Quick Arm
1
Re-Exit
2
Auto Bypass
3
Silent Panic
4
Audible Panic
5
Auxiliary 1
6
Auxiliary 2
7
Multi Keypress Tamper
8
LED Extinguish enable
1
Require user code for bypassing zones
2
3
Bypass sounder alert
4
AC Power/Low Battery sounder alert
5
Enables Bypass toggle
6
Enables Silent Auto Arm
7
Enables Automatic Instant
8
Reserved
Open/Close
1
Bypass
2
Restore
3
Trouble
4
Tamper
5
Cancel
6
Recent Closing
7
Exit Error
8
109 35 PARTITION 8, ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1) 0 _ Segment #2 (Exit Time #1) 0 _ Segment #3 (Entry Time #2) 0 _ Segment #4 (Exit Time #2) 0 _
110 35 ZONE TYPE 1 ALARM EVENT CODE 8 _
111 35 ZONE TYPE 1 CHARACTERISTIC SELECT
Segment #1 (Circle numbers to program)
Delay 1 zone (enable to follow Timer 1 Entry/Exit
1
Fire (enable for fire zone).
2
24 Hour (enable for non-fire 24 hour
zone).
3
Keyswitch zone.
4
Follower (enable for burg zones that are
instant during non-entry times).
5
times).
Delay 2 zone (enable to follow Timer 2 Entry / Exit
6
times).
Interior (Enable for auto bypass or stay arming).
7
Local Only (enable if zone is not to be reported).
8
Segment #2 (Circle numbers to program) 1
Keypad audible on alarm.
2
Yelping siren on alarm.
3
Temporal siren on alarm.
4
Chime.
5
Bypassable.
6
Group Shunt.
7
Force armable.
8
Entry Guard.
Segment #3 (Circle numbers to program)
1
Fast Loop Response.
2
Double End of Line Tamper zone.
3
Trouble zone (Day zone).
4
Cross Zone.
5
Dialer Delay zone.
6
Swinger zone.
7
Restore reporting.
8
Listen-In.
THE DEFAULTS LISTED IN THE ODD NUMBERED LOCATIONS BELOW REPRESENT TH E THREE SEGMENTS OF
EACH OF THOSE LOCATIONS. USE THE THREE SEGMENT CHARTS FROM LOCATION 111 TO UNDER STAND
THESE DEFAULTS.
35 ZONE TYPE 2 ALARM EVENT CODE
35 ZONE TYPE 2 CHARACTERISTIC SELECT
35 ZONE TYPE 3 ALARM EVENT CODE
36 ZONE TYPE 3 CHARACTERISTIC SELECT
36 ZONE TYPE 4 ALARM EVENT CODE
36 ZONE TYPE 4 CHARACTERISTIC SELECT
36 ZONE TYPE 5 ALARM EVENT CODE
36 ZONE TYPE 5 CHARACTERISTIC SELECT
36 ZONE TYPE 6 ALARM EVENT CODE
36 ZONE TYPE 6 CHARACTERISTIC SELECT
36 ZONE TYPE 7 ALARM EVENT CODE
36 ZONE TYPE 7 CHARACTERISTIC SELECT
36 ZONE TYPE 8 ALARM EVENT CODE
36 ZONE TYPE 8 CHARACTERISTIC SELECT
36 ZONE TYPE 9 ALARM EVENT CODE
36 ZONE TYPE 9 CHARACTERISTIC SELECT
36 ZONE TYPE 10 ALARM EVENT CODE
37 ZONE TYPE 10 CHARACTERISTIC SELECT
37 ZONE TYPE 11 ALARM EVENT CODE
37 ZONE TYPE 11 CHARACTERISTIC SELECT
37 ZONE TYPE 12 ALARM EVENT CODE
37 ZONE TYPE 12 CHARACTERISTIC SELECT
37 ZONE TYPE 13 ALARM EVENT CODE
37 ZONE TYPE 13 CHARACTERISTIC SELECT
37 ZONE TYPE 14 ALARM EVENT CODE
37 ZONE TYPE 14 CHARACTERISTIC SELECT
37 ZONE TYPE 15 ALARM EVENT CODE
37 ZONE TYPE 15 CHARACTERISTIC SELECT
37 ZONE TYPE 16 ALARM EVENT CODE
37 ZONE TYPE 16 CHARACTERISTIC SELECT
38 ZONE TYPE 17 ALARM EVENT CODE
38 ZONE TYPE 17 CHARACTERISTIC SELECT
38 ZONE TYPE 18 ALARM EVENT CODE
38 ZONE TYPE 18 CHARACTERISTIC SELECT
38 ZONE TYPE 19 ALARM EVENT CODE
38 ZONE TYPE 19 CHARACTERISTIC SELECT
38 ZONE TYPE 20 ALARM EVENT CODE
38 ZONE TYPE 20 CHARACTERISTIC SELECT
6-1245-5678
457-125-45678
457-1256-5678
457-125-25678
2
24-5-78
3
3-0-0
5
4
0-12458-5678
7
5-12456-5678
5
4
0-12456-5678
7
5-1245-25678
5
4
0-1245-25678
7
6-1245-25678
_
_
_
_
_
_
_
_
_
_
_
ZONE WORKSHEET
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
NX-8 Control
51
Page 52
APPENDIX 1 REPORTING FIXED CODES IN CONTACT ID AND SIA
The table below list the event codes sent for the following reports (if enabled) when using CONTACT ID or SIA formats.
REPORT
MANUAL TEST 601 RX
AUTOTEST 602 RP
OPEN (user number) 401 OP
CLOSE (user number) 401 CL
CANCEL (user number) 406 OC
DOWNLOAD COMPLETE 412 RS
START PROGRAM 627 LB
END PROGRAM 628 LX
GROUND FAULT 310 GF
GROUND FAULT RESTORE 310 GK
RECENT CLOSE (user number) 401 CR
EXIT ERROR (user number) 457 EE
EVENT LOG FULL 605 JL
FAIL TO COMMUNICATE 354 RT
EXPANDER TROUBLE (device number) 333 ET
EXPANDER RESTORE (device number) 333 ER
TELEPHONE FAULT 351 LT
TELEPHONE RESTORE 351 LR
SIREN TAMPER (device number) 321 YA
SIREN RESTORE (device number) 321 YH
AUX POWER OVER CURRENT (device number) 312 YP
AUX POWER RESTORE (device number) 312 YQ
LOW BATTERY (device number) 309 YT
LOW BATTERY RESTORE (device number) 309 YR
AC FAIL (device number) 301 AT
AC RESTORE (device number) 301 AR
BOX TAMPER (device number) 137 TA
BOX TAMPER RESTORE (device number) 137 TR
KEYPAD TAMPER 137 TA
KEYPAD PANIC (audible) 120 PA
KEYPAD PANIC (silent) 121 HA
DURESS 121 HA
KEYPAD AUXILIARY 1 110 FA
KEYPAD AUXILIARY 2 100 MA
RF SENSOR LOST (zone number) 381 *T
RF SENSOR RESTORE (zone number) 381 *R
SENSOR LOW BATTERY (zone number) 384 XT
SENSOR BATTERY RESTORE (zone number) 384 XR
ZONE TROUBLE (zone number) 380 *T
ZONE TROUBLE RESTORE (zone number) 380 *R
ZONE TAMPER (zone number) 137 TA
ZONE TAMPER RESTORE (zone number) 137 TR
ZONE BYPASS (zone number) 570 *B
BYPASS RESTORE (zone number) 570 *U
CONTACT ID SIA
THE NUMBER IN PARENTHESES FOLLOWING THE EVENT IS THE NUMBER THAT WILL BE REPORTED AS THE
ZONE NUMBER. IF THERE ARE NO PARENTHESES, THE ZONE WILL BE A0". SEE PAGE 54 FOR THE DEVICE
NUMBERS.
* The character transmitted in this slot will be the first character from the event code of the zone that is
bypassed or in trouble. (See locations 110 - 141)
52
NX-8 Control
Page 53
APPENDIX 2 REPORTING ZONE CODES IN SIA OR CONTACT ID
The NX-8 has the ability to report SIA level 1 transmissions to either or both phone numbers. Each report in SIA consists of a n
Event Code and a Zone or User ID. The Zone ID will be the zone number that is in alarm. The event code will come from the
chart below and be programmed in the zone type event code.
Programmed Event Code
0 HA Holdup Alarm
1 FA Fire Alarm
2 PA Panic alarm
3 BA Burglary Alarm
4 BA Burglary Alarm
5 BA Burglary Alarm
6 UA Untyped Alarm
7 BA Burglary Alarm
8 BA Burglary Alarm
9 UA Untyped Alarm
10 HA Holdup Alarm
11 MA Medical Alarm
12 PA Panic alarm
13 TA Tamper Alarm
14 RP Periodic Test
15 GA Gas Alarm
16 KA Heat Alarm
17 WA Water Alarm
18 QA Emergency Alarm
19 SA Sprinkler Alarm
20 ZA Freeze Alarm
The NX-8 has the ability to report Ademco Contact ID transmissions. Each report in Contact ID consists of an Event Code and
a Zone ID. The zone ID is the zone that created the alarm. The event code will come from the chart below and be programmed
in the zone type event code.
Programmed Event Code
0 122 Silent Panic
1 110 Fire Alarm
2 120 Panic alarm
3 130 Burglary Alarm
4 131 Perimeter Alarm
5 132 Interior Alarm
6 133 24 Hour Burglary
7 134 Entry Alarm
8 135 Day/Night Alarm
9 150 Non Burglary 24 Hour
10 121 Duress Alarm
11 100 Medical Alarm
12 123 Audible Panic Alarm
13 137 Tamper Alarm
14 602 Periodic Test
15 151 Gas Detected
16 158 High Temp
17 154 Water Leakage
18 140 General Alarm
19 140 General Alarm
20 159 Low Temp
SIA Code Description
Contact ID Code Description
NX-8 Control
53
Page 54
APPENDIX 3 EXPANDER NUMBERS FOR REPORTING EXPANDER TROUBLE
The tables below list the device numbers that will be reported for trouble conditions.
KEYPAD PART 1 PART 2 PART 3 PART 4 PART 5 PART 6 PART 7 PART 8
All switches off 35 84 (All switches off)
Switch 1 on 36 85 (Switch 1 on)
Switch 2 on 37 86 (Switch 2 on)
Switches 1 & 2 on 38 87 (Switch 1 & 2 on)
Switch 3 on 39 88 (Switch 3 on)
Switches 1 & 3 on 32 89 (Switch 1 & 3 on)
Switches 2 & 3 on 33 90 (Switch 2 & 3 on)
Switch 1, 2 & 3 on 34
Device
Device # reported
NX-8 Control Panel 0 See page 53 for possible report codes.
NX-534E Two Way Listen-In 64
NX-540E “Operator” 40
NX-591E Cellemetry Interface 76
NX-870E Fire Supervision 9
For CE labeled products, please refer to page 57 for specific electrical requirements.
NX-8 Control
55
Page 56
TERMINAL DESCRIPTION
TERMINAL
R1
R
T
T1
EARTH
AC
BELL + &
BELL -
KP DATA
KP COM
KP POS
SMOKE+
COM
AUX PWR+
ZONE 8
COM
ZONE 7
ZONE 6 -
ZONE 1
AUX 4 –
AUX 1
(Note: These numbers are for one keypad at the end of the wire. When connecting more than one keypad to the end of
DESCRIPTION
House Telephone Ring (Grey).
Telephone Ring (Red).
Telephone Tip (Green).
House Telephone Tip (Brown).
Earth Ground. Connect to a cold water pipe or a 6 to 10 foot driven rod.
AC input. Connect to a 16.5V 25, 40 or 50 VA Class ll U.L. approved transformer.
If used as a siren output(default), the speaker rating should be 15 watt at 8 or 16 ohm, or 30/40
watt at 4, 8, or 16 ohms. If voltage output is selected in location 37, this output becomes voltage
output, 12VDC, 1 Amp maximum load. NOTE: A 3.3K Ω resistor may be required across the
bell terminals when a 12 VDC siren is used. If no resistor is used, you may experience
voltage leakage into the siren which will cause these devices to output a small signal.
Connect to the data terminal on the keypads and the expanders. Maximum number of devices
(keypads + expanders) is 32. See AMaximum Wire Run@ chart below.
Connect to the Common terminal on the keypads and the expanders.
Connect to the POS terminal on the keypads and the expanders. This terminal and AUX PWR +
are limited to 1 amp total current when added together.
Smoke detector power 12VDC, 1.5 amps maximum (For those jurisdictions which allow the
Priority zone to be used with smoke detectors.)
Connect negative wire of powered devices such as motion detectors and smoke detectors.
Connect positive wire of all powered devices except smoke detectors and keypads. This terminal
and KP POS are limited to 1 amp total current when added together.
Connect to one side of zone 8 loop. Connect the other side to com terminal. Open or short causes
alarm. Zone 8 may be used for a two-wire smoke detector using a 680 Ω E.O.L. resistor. W3
must be set for two-wire smoke detector loop. For normal zone operation, W4 m ust be set.
Common (-) terminal for zones 7 & 8. (See the wiring diagram for examples.)
Connect to one side of zone 7 loop. Connect the other side to COM terminal. Open or short
causes alarm.
Connect as described for zones 7 & 8. Only zone 8 can be a two-wire zone. (See the wiring
diagram for examples.)
Connect negative lead of low current device [relay, LED(install 1kΩ resistor in series with LED),
etc.]. Connect positive lead of device to AUX PWR +. Current is limited to 50mA when output is
negative, and 250FA when output is positive.
NETWORX KEYPAD MAXIMUM WIRE RUN
the wire, a higher gauge wire will be required.)
Length in feet
250
500
1000
1500
2500
WHEN CONNECTED TO NX-8
Wire Gauge
24
20
18
16
14
WHEN CONNECTED TO NX-320
Wire Gauge
22
18
16
14
12
56
NX-8 Control
Page 57
REGULATORY NOTICES
LOCAL TELEPHONE COMPANY INTERFACE
INFORMATION
Telephone Connection Requirements
Except for telephone company provided ringers, all connections
to the telephone network shall be made through standard plugs
and standard telephone company provided jacks or equivalent in
such a manner as to allow for immediate disconnection of the
terminal equipment. Standard jacks shall be so arranged that if
the plug connected thereto is withdrawn, no interference to the
operation of the equipment at the customer’s premises which
remains connected to the telephone network, shall occur by
reason of such withdrawal.
Incidence Of Harm
Should terminal equipment or protective circuitry cause harm to
the telephone network, the telephone company shall, where
practical, notify the customer that temporary discontinuance of
service may be required. However, where prior notice is not
practical, the telephone company may temporarily discontinue
service if such action is deemed reasonable in the circumstances.
In the case of such temporary discontinuance, the telephone
company shall promptly notify the customer who will be given the
opportunity to correct the situation. The customer also has the
right to bring a complaint to the FCC if he feels the disconnection
is not warranted.
Changes In Telephone Company Equipment Or
Facilities
The telephone company may make changes in its
communications facilities, equipment, operations, or procedures
where such action is reasonably required and proper in its
business. Should any such change render the customers terminal
equipment incompatible with the telephone company facilities, the
customer shall be given adequate notice to make modifications to
maintain uninterrupted service.
General
The FCC prohibits customer provided terminal equipment be
connected to party lines.
Importance Of The Ringer Equivalence Number
The Ringer Equivalence Number (REN) of this device is 0.1B.
This number is a representation of the electrical load that it
applies to your telephone line.
Malfunction Of The Equipment
In the event that the device should fail to operate properly, the
customer shall disconnect the equipment from the telephone line
to determine if it is the customers equipment that is not
functioning properly. If the problem is with the device, the
customer shall discontinue use until it is repaired.
Equipment Information
Manufacturer Of Connecting Equipment:
CADDX CONTROLS, INC.
FCC Registration Number:
GCQUSA-31771-AL-T, RINGER EQUIVALENCE: 0.1 B
(Applies to products which have the CE mark attached)
CE DECLARATION OF CONFORMITY
Manufacturer’s Name: Caddx Controls
Manufacturer’s Address: 1420 North Main Street
Gladewater TX 75647
EU Representative: Interlogix Europe
Product Identification
We declare under our sole responsibility that th is product is in
conformity with Directive 1999/5/EC (R&TTE); Directive
73/23/EEC (LVD); and Directive 89/336/EEC (EMC) and base d
on test results using (non)-harmonized standards in accordance
with the Directives mentioned.
Additional Tests
This equipment has been tested and found to comply with the
following standards (which are no longer required for
compliance).
Network Compatibility Declaration
We declare under our sole responsibility that this product is
designed to work with the networks in the countries marked with
a check () and may have interworking problems with the
countries that are not checked. Due to the inherent differences in
the individual PSTNs, certain software settings may need to be
adjusted on a country-to-country basis. If it is desired to use this
equipment on a network other than the one on which it was
originally installed, you should contact your equipment supplier.
() Austria (_) Liechtenstein
() Belgium () Luxembourg
() Denmark () Netherlands
() Finland () Norway
() France () Poland
() Germany () Portugal
() Greece () Spain
() Iceland () Sweden
() Ireland () Switzerland
() Italy () United Kingdom
Telecom Approval Notice
This equipment has been approved in accordance with the
Council Decision 98/482/EC for pan-European, single t erminal
connection to the public switched telephone network (PSTN).
However, due to the differences between the individ ual PSTNs
provided in different countries, the approval does not, of itself,
give an unconditional assurance of successful operation on every
PSTN network termination point. In the event of problems, you
should contact your equipment supplier in the first instance.
Electrical Requirements
This device automatically adjusts to voltages within the range of
230 V 50/60 Hz. Fuse: Type T 200mA 250 VAC
NX-8 Control
57
Page 58
UNDERWRITERS LABORATORIES INFORMATION
The NetworX NX-8 holds the following listings from Underwriters Laboratories (US and Canadian):
Household Burglary (UL1023) (ORD-C1023-1974)
Household Fire (UL985) (CAN/ULC S545-M89)
Local Grade A Mercantile, Police Station Connect with Basic Line Security (UL609) (requires #NX-003-C enclosure) (CAN/ULC
S303-M91)
Grade B & C Central Station Burglar Alarm Unit (UL1610) (CAN/ULC S304-M8 8)
Home Health Care Signaling (UL1637)
When installing an NX-8 in compliance with Underwriters Laboratories, the following instructions must be observed:
! Initiating and indicating devices must be rated at 11.5 to 12.4 V DC residential, 12.0 V DC commercial.
! When using partitioning in Commercial Burglary applications, the ma in control must be protected by a 24-hour alarm circuit.
! Force Armin g and Aut o Arming shall not be enabled.
! For residential fire applications, the indicating devices shall be a Wheelock 34T-12 or equivalent.
! The "Listen-In" feature shall not be enabled.
! The Siren/Bell Test shall be enabled. The auxiliary outputs controlling the audible d evice require a mini mum cutoff time of 15 minutes for
commercial burglary, 4 minutes for residential applications, or 30 minutes for commercial burglary for Canada.
! For residential fire installations, the Dynamic Battery Test time cannot exceed four ( 4) hours.
! Ringback shall be enabled on UL commercial burglary installations.
! On co mmercial burglary installations, the fire initiating circuits shall not be connected.
! The Entry-Guard feature shall be disabled.
! Group Bypassing shall be disabled.
! Delay before dial seizure shall be set to "0".
! Total c urrent draw from aux power connections at terminal positions POS, AUX PWR, and SMOK E PWR must not excee d 400 mA.
! Remote Downloading shall not be used on UL listed systems.
! For residential burglary applications, the maximum entry and exit delay times shall be 45 and 60 seconds respectively. The exit delay
time shall not exceed 60 seconds for commercial burglar alarm applications.
! The keyswitch option shall not be used.
! The telephone line monitor shall be enabled.
! The Telephone Line Cut delay shall not exceed 90 seconds.
! 24-hour communicator test transmission is required.
! For 24 hours of standby power using a 7.0 AH battery, limit auxiliary power load to 140 mA.
! For 24 hours of standby power using a 17.2 AH battery, limit auxiliary power load to 400 mA.
! The silent keypad option shall not be enabled.
! UL has only verified compatibility with the following listed DACRs and formats: Sure-Gard SG-MLR2-DG: 2,9,10,12,13,14; Silent Knight
9000 - 2,12; FBI - CP220FBI, 13; and Ademco 685: 2,11,12, and 13.
! For burglary installations, cross-zoned detectors shall overlap 100 percent in the area of coverage and similar coverage areas must be
used. For example, interior protection is cross-zoned with interior prot ection, and so on.
! Expander trouble must activate the siren (Loc 37, Segment 2, LED 2)
! For UL 1637, expander trouble must activate keypad sounder (Loc 39, Segment 1, LED 8)
! For Canadian installations, the class II transformer secure tab shall not be employed.
! The 4-wire smoke detector employed shall be rated to operate over the voltage range of 11.5 to 12.4V.
! Compatible listed devices: (Special Applications)
o Bell Output (Sirens): Wheelock models: NS-1215W, NS-121575 W, NS4-1215W, NS4-1215 75 W, AS-12 15 W, AS-12157 5 W
o Horn / Strobe: System Sensor: S1224MC Strobe series; 1224MC Horn/Strobe series; H12/24 Horn series
o Smoke Output (4 wire detectors):
! The Net worX NX-8 panel is necessary to initiate Residential and Commercia l installations.
! At least one compatible keypad is needed for all applications.
! At least one bell fixture is required for all applications, except Grade C Central Statio n. For Grade A Local, the AD10-12 bell and
Grade A bell housing shall be used.
! Comm ercia l UL applica tion s require #NX-003-C m etal en closure. Supp lied scre ws to be used.
! A minimum of two (2) keypads are required for Home Health applications and each keyp ad must be set to a unique address.
! The wireless devices are only UL listed for residential applications.
! The DACT shall be enabled for all commercial burglary applications.
58
NX-8 Control
Page 59
ANSI / SIA CP-01 REQUIREMENTS
Must be programmed as part of the
IMPORTANT NOTE: UL requirements take priority over SIA requirements.
To meet SIA CP-01 requirements –
•
Minimum System Requirements: 1 control panel; 2 keypads (or 1 keypad per partition for multi-partitioned systems)
• Remote arming shall NOT be enabled in SIA classified installations.
• Off-premise transmission must be in the SIA format.
• The Abort window and Entry Delay must not exceed 1 minute.
• CAUTION – A call waiting cancel on a non-call waiting line will prevent successful connection to the central station.
– for Silent Exit
Exit Time Restart This feature is non-programmable in the panel. Enabled
Auto Stay Arm on Unvacated Premises Auto Bypass
Exit Time and Progress
Annunciation / Disable
– for Remote Arm
Entry Delay(s) Entry 1 Delay
Entry 2 Delay
Abort Window
– for Non-Fire Zones
Abort Window Time
– for Non-Fire Zones
Abort Annunciation This feature is non-programmable in the panel. -- Flashing Cancel LED goes off when disarming. Enabled
Cancel Annunciation Cancel
Duress Feature Duress
Cross Zoning
Programmable Cross Zoning Time
Swinger Shutdown Swinger Shutdown Count
Swinger Shutdown Disable Swinger Shutdown Count
Fire Alarm Verification Fire Alarm Verification Time
Call Waiting Cancel
Default Changes (from prior versions):
Exit Error
Power Up Delay
This feature is non-programmable in the panel. -- Exit time and progress are always enabled. Enabled (may be disabled for remote arming)