GE Monogram ZDP30N4DSS, Monogram ZDP30N4YSS, Monogram ZDP30L4YSS, Monogram ZDP30L4DSS Dimensions And Specifications

Monogram.
Specification Created 7/01
ZDP30N4DSS - GE Monogram™30" Free-Standing Professional Gas Range
Dimensions and Specifications (in inches)
30" Natural Gas Model:
ZDP30N4YSS–4 gas burners
30" Liquid Propane Gas Model:
ZDP30L4YSS–4 gas burners
Accessory Requirements:
All models require the installation of a backguard. A backguard should be ordered at the same time as the range. Both must be on site at the time of installation.
Order one backguard for 30" models:
ZX1B30YSS–1-1/2" high backguard (required for island installations) ZX12B30YSS–9" high backguard ZX22B30YSS–22" high backguard with warming rack (2 piece)
Advance Planning:
Refer to dimensional drawings for appropriate placement and necessary clearances when planning the installation.
Cabinetry cannot be installed directly above the range.
This range requires the installation of a vent hood,
30" to 36" above the surface.
The vent hood must be at least 24" deep. The vent hood must be the same width as the range. The vent hood must provide at least 600 CFM and
up to 800 CFM.
Working areas adjacent to the range should have 18" minimum clearance between countertop and cabinet bottom.
Clearance between range and side wall or combustible material must be at least 12" on each side.
21-1/4"
12"
1-1/2"
35-1/4"-36-3/4"
26-3/4"
29-7/8"
Available Backguards
ZX22B30YSS
ZX12B30YSS
ZX1B30YSS
R
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center®service, 800.626.2000.
Monogram.
Specification Created 7/01
ZDP30N4DSS - GE Monogram™30" Free-Standing Professional Gas Range
Dimensions and Specifications (in inches)
If the range is installed in an island:
Allow 12" min. clearance at the back to combustible
materials.
Allow 36" min. above the cooking surface to combustible materials.
The vent hood must provide at least 600 CFM and up to 1200 CFM.
Installation must conform with local codes. In the absence of local codes, the range must comply with the National Fuel Gas Code, ANSI Z223.1-1990.
A.G.A. approved
Installation Information:
Before installing, consult installation instructions (Pub. #49-8786) packed with product for current dimensional data.
3/-1/4"
18" Min.
4"
35-3/8" Max. for Counter Level 36-3/4" Max. with Range Leveling Legs Fully Extended
3/-1/2"
Gas Supply
Electrical Supply
Cooking Surface
13"
Max.
4"
12"
30" Wide Range Hood
12" Min. to Combustible Material Each Side
36" Min. to Combustible Material From Cooking Surface
12"
Low Back
High Shelf
27-3/8"
12"
3-1/4"
21-1/4"
12"
36" Min.
to Combustibles
26-3/4"
29-1/4"
43-7/8"
0" Clearance
Island Trim
12" Min. to Combustables Without Backgaurd
1-1/2"
36" Min.
to Combustibles
0" Clearance
R
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center®service, 800.626.2000.