Installation Instructions
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT- Save these instructions for
local inspector's use.
IMPORTANT- Observe all governing codes
and ordinances.
Note to Installer - Be sure to leave these instructions with the Consumer.
Note to Consumer - Keep these instructions
with your Owner's Manual for future reference.
WARNING:
This appliance must be properly grounded. See "Power Supply", page 4.
AVERTISSEMENT :
Get appareil doit _tre correctement mis
la terre. Consulter _{Alimentation
_lectrique _, page 4.
If you received a damaged ice machine, you should
immediately contact your dealer or builder.
Proper installation is the responsibility of the installer. Product failure due to improper installation is not
covered under the GEAppliance Warranty. See the Owner's Manual for warranty information.
Use this appliance only for its intended purpose.
Check with local utilities for electrical codes that apply in your area. Local codes vary. Installation, electrical
connections and grounding must comply with applicable codes. In the absence of local codes, the ice machine should be installed in accordance with
National Electrical Code ANSl/NFPA 70-1990 or latest edition.
For Monogram local service inyour area, call
1.800.444.1845.
For Monogram Service in Canada, call
1.888.880.3030.
For Monogram Parts and Accessories, call
1.800.626.2002.
CONTENTS
Design Information
Models Available ..............................................................3
Cutout & Product Dimensions ........................................3
Optional Accessories ......................................................3
Tools and Materials Required ......................................3
Installation
Advance Planning ............................................................4
Power Supply ....................................................................4
Remove Packaging ..........................................................5
Adjust Height of Ice Machine ........................................5
Water Supply ....................................................................6
Connect the Drain ............................................................6
Connect Water Supply ....................................................7
Reverse Door Swing ....................................................7, 8
Accessories
ZIP75WW, ZIP75BB Kit for 3/4" thick panels ........9, 10
Design Information
MODELS AVAILABLE
ZDI15, ZDIS15 Available in black, white and stainless steel.
The ice machine may be installed below a countertop or used free-standing.
CUTOUT & PRODUCT DIMENSIONS
34" min.
Adjustable
to 34-1/2"
Cutout dimensions shown allow for a full door swing.
When installing a 3/4"thick custom door panel,
additional clearances atthe sides may be required. Frameless Cabinets:
If installing between frameless cabinets, a 1/2" filler strip or side panel may be required on the hinge side. The filler strip will act as a spacer between the door
case and adjacent cabinet, and will prevent interference with icemaker door swing. The width of
the opening must include filler or side panel thickness.
NOTE: The addition of a 3/4" thick front panel will result in a front to back depth of 24-1/16."
23-5/16" to
14-13/16'
OPTIONAL ACCESSORIES
ZIP75WW White and ZIP75BB Black--For the installation of atrimless 3/4" thick custom panel on
white and black models (not for stainless steel models). A custom handle of your choice may be installed onto the 3/4" panel. See installation instructions on pages 9 and 10.
ZPK1--Drain Pump Kit. For use when a floor drain is not available.
TOOLS AND MATERIALS REQUIRED
1/4" socket
3/4" adjustable wrench
•Level
GE SmartConnectTM Refrigerator Tubing Kit or 1/4" O.D. copper tubing, of sufficient length to reach the installation
3
Installation Instructions
ADVANCE PLANNING
CAUTION: Duetoexcessive
weight, TWO PEOPLEARE REQUIREDTO MOVE AND INSTALL THIS ICE MACHINE.
MISE EN GARDE :
A cause de son poids elev&lL FAUT DEUX PERSONNES POUR DEPLACER ET
INSTALLERCEDISTRIBUTEUR DE GLACE.
Choose the location:
The ice machine must be installed in an area protected from elements such as wind, rain, water
spray or drip. The area should be ventilated with temperatures above 55°F (13°C) and below 110°F (43°C). Best results are obtained between 70°F (21°C) and 90°F (32°C).
The ice machine may be closed in on the top and three sides as long as the front is unobstructed for air circulation and proper operation.
-Installation should be such thatthe ice machine can be moved forward for servicing, if necessary.
-The bottom grille on the front must be unobstructed
to provide proper air flow.
Before you begin:
1. If a custom panel is to be installed, follow the
instructions shown on pages 9 and 10.
-Order ZIP75 (black or white) panel kit.
-Order the custom panel from the cabinet manufacturer.
-Secure the custom panel onto the ice machine.
2. Determine a method of drainage. If a floor drain is to be installed, the drain must be accurately
located. The installation of a custom door panel will
affect the drain location. See page 6 to determine the exact location of the floor drain, front to back, with or without a custom door panel.
-A drain pump kit, ZPK1, is available and will not
interfere with placement of the ice machine.
3. The door swing is reversible. If desired, change the door swing before installation.
4. Slide the ice machine into the installation location.
-Open and close the door to be sure there is no interference.
-Check to be sure the ice machine can be moved back into the opening, flush with adjacent
cabinetry. There should be no interference with
the floor drain.
POWER SUPPLY
IMPORTANT: (Please read carefully).
FORPERSONAL SAFETY,THIS APPLIANCE MUST BE
PROPERLYGROUNDED.
Do not use an extension cord or adapter plug with this appliance. Follow National Electrical Code or prevailing local codes and ordinances.
This ice machine must be supplied with 115V,60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.
Electrical Supply Should Enter From Back Wall
InShaded Area.
A properly grounded 3-prong receptacle should be located within reach of the ice machine's 66" long power cord. For a built-in installation, locate the receptacle in the shaded area shown.
IMPORTANT: (Please read carefully).
The power cord of this appliance is equipped with a three-prong (grounding) plug that mates with a standard three-prong grounding wall receptacle to minimize the possibility of electric shock. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded and has the correct polarity.
Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle.
Do not,under any circumstances, cut or remove the third (ground) prong from the power cord.
DO NOT USEAN EXTENSION CORD.