L1M LOWMOUNT® 150 LUMINAIRE
Low Bay, Enclosed
APPLICATIONS
• Low mounting height 8-20 ft. (2-6 meters) applications in factories, foundries, canneries and
textile, metal, chemical, rubber, food, cement, and other industrial applications
SPECIFICATION FEATURES
• 1598 Listed
Suitable For Damp Locations
• 1598 Listed for metal
halide
lamps in polymeric lamp
containment barriers
• Listed to Canadian
Standards
• Enclosed and gasketed optics
ORDERING NUMBER LOGIC
L1M
PRODUCT
IDENT
XXX
L1M = Lowmount 150
Luminaire
25
WATTAGE
XX
07 = 70
10 = 100
15 = 150
(55V)
25 = 250
S
LIGHT
SOURCE
X
E = Energy
Act Compliant Pulse MH
(EPMH)
S = HPS
NOTE:
Lamp is tilted
base up
20° above
horizontal
except 175
watt metal
halide is
vertical base
up. Lamp not
included.
0
VOLTAGE
X
60Hz
0 = 120/208/
240/277
MULTIVOLT
1 = 120
2 = 208
3 = 240
4 = 277
5 = 480
D = 347
F =
50Hz
6 = 220
R = 230
Y = 240
PHOTOMETRIC SELECTION TABLE
Lowmount 150
Wattage Light Maximum Spacing
Source Ambient Criteria or IES Curve
Distribution
Type
70, 100, 150 HPS 55C 1.7 175762
250 HPS 40C 1.7 175851
250 EPMH 40C 1.5 177180
250
Note: See page T-34 for Alternative lens material explanation
A
BALLAST
TYPE
X
See Ballast Selection
Table
A = Autoreg
G = Mag-Reg with
Grounded Socket
Shell
H = HPF Reactor or Lag
K = Hot Restart
M = Mag-Reg
120X347
EPMH(Coated)
• Charcoal ltered optics
• Alzak† nish on reector
• Die-cast aluminum ballast
housing with polyester
powder gray paint nish
• UV stabilized injection molded
prismatic refractor for low
brightness
• Safety chain provisions
4
AMBIENT
DEG. C
X
4 = 40
5 = 55
NOTE: Limit
40°C for 250
watt and all
severe duty
40C 1.5 175839
17
SPACING
CRITERIA
XX
15 = 1.5
17 = 1.7
TA
OPTICAL
CODE
XX
TA = Enclosed
Acrylic
Photometric
• Mogul base socket -E39
standard
• Shipped as components:
Ballast, Optical
• Magnapack available
for ballast.
D
OPTIONS
X
B = Time Delay Automatically Switch
Quartz
D = Severe Duty (Meets Wet location)
E = Provision for slide on Primary
Electrical Disconnect. Order
TWOBP Box (Thru feed
capability only) separately. (Not
available with D or W option).
F = Fusing
J = Prewire with Loop, cord, and
plug part of Power Hook.
Order Receptacle/Hook Box
separately, (Not CSA/CUL)
M = Prewire with Loop, 3-ft (0.9 meters)
#16-3 Cord, and Nema Plug.
(Order Locking Receptacle
Hook Box Separately)
N = Provision for slide on primary Electrical
Disconnect. Order PED Box (Pendant
and thru feed capability) separately.
(Not available with D or W option)
P = Prewire with Hook, 3-ft (0.9 meters)
#16/3 Cord and Nema Plug
Q = Non-Time Delay Automatically
Switch Quartz
W = Wet Location
Note: See page I-104 for Accessory Index
and Descriptions.
Note: See page I-129 for explanation of
Options.
I-80/2008
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
Most commonly ordered
L1M LOWMOUNT® 150 LUMINAIRE
Low Bay, Enclosed
REFERENCES
See Page I-104 for start of Accessories.
See Page I-117 for Component Ordering Logic.
See Page I-129 for Explanation of Options and Other Terms Used.
DATA
Approximate Net Weight lbs kgs
Ballast and Optical 25-33 11-15
FIXTURE DIMENSIONS
BALLAST SELECTION TABLE
60HZ 50HZ
120, 208 120
Light 240, 277 x
Wattage Source Multivolt 480 347 347 220 220 230 240 380
70 HPS A,H,K G,K,M H,G H N/A N/A N/A N/A N/A
100 HPS A,H,K G,K,M H,G H N/A N/A N/A N/A N/A
150(55V) HPS A,H,K G,K,M H,G H N/A N/A N/A N/A N/A
250 HPS M M,G A,G A N/A A,H A ,H A ,H M
250 EPMH A A A A N/A A A A N/A
NOTE: N/A = Not Available
* 480 volt not available
CANADIAN NOTES:
1. “A”, Autoreg, 120, 277 or 347 volts only
2. 208, 240, and 480 volts require CWI ballast. Use “G” when available. Contact factory for
all others.
3. Multivolt not available.
4. “K” Hot Restart not available.
5. 208, 240 and 480 volts with “G” ballast not available with switched quartz.
Ballast Type / Voltage
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
2008/I-81