GE Appliances
JVM1850BF/CF/WF – GE Spacemaker® 1.8 Cu. Ft. Over-the-Range Microwave Oven
Dimensions (in inches)
66" MIN. |
|
|
|
Mounting |
30" |
MIN. |
Exhaust outlet |
height |
width |
required |
|
from floor |
|
|
connects to |
|
|
|
3-1/4" X 10" duct |
|
|
|
|
|
12" |
|
|
MAX. |
|
|
15 |
|
21-3/4" |
16-13/32 |
|
15-3/4 |
||
Door open |
||
|
Note: Requires 120V grounded outlet. Electrical receptacle must be located in cabinet above Spacemaker microwave oven. No additional wiring, venting or cabinet rebuilding necessary in many cases. Complete detailed, easy-to-follow installation instructions and convenient full-size templates are packed with the Spacemaker microwave oven.
Important Information: When installing the Spacemaker microwave oven over a range, allow minimum of 2" from bottom of Spacemaker microwave oven to top of range backguard to allow for removal of light covers.
Installation Information: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
|
Listed by |
|
Underwriters |
R |
Laboratories |
|
For answers to your Monogram,® GE Profile™ or |
|
GE appliance questions, visit our website at |
|
GEAppliances.com or call |
Specification Revised 3/03 |
GE Answer Center® service, 800.626.2000. |
GE Appliances
JVM1850BF/CF/WF – GE Spacemaker® 1.8 Cu. Ft. Over-the-Range Microwave Oven
Optional Accessories (Available at additional cost)
Filler Panel Kits
JX52CT–Bisque
JX52BL–Black
JX52WH–White
When replacing a 36" or 42" range hood, this kit fills in the additional width to provide a custom built-in appearance.
For installation between cabinets
only; not for end-of-cabinet installation Each kit contains two 3"-wide filler Two kits are needed for a 42" opening
3/8" |
19 |
depth |
30 |
Filter Kits
JX81B–Recirculating Charcoal Filter Kit
To be used when the Spacemaker microwave oven cannot be vented to the outside.
JX22SS–Stainless Steel Decorative Panel Kit
When replacing a Hi/Low range with a microwave/convection oven or Spacemaker over a range model, this panel kit fills in the area between the microwave and range left by the Hi/Low model.
Specification Revised 3/03
HOOD EXHAUST DUCT
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard 3-1/4” x 10” rectangular duct.If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6” diameter duct
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs,or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of 3-1/4” x 10” rectangular or 6” diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS,WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
Duct |
Equivalent Feet |
A. Rectangular-To-round |
5 ft. |
Transition Adaptor |
|
B. Wall Cap |
40 ft. |
|
|
C. 90° Elbow |
10 ft. |
|
|
D. 45° Elbow |
5 ft. |
|
|
E. 90° Elbow |
25 ft. |
|
|
F. 45° Elbow |
5 ft. |
|
|
G. Roof Cap |
24 ft. |
|
|
For answers to your Monogram,® GE Profile™ or |
|
|
GE appliance questions, visit our website at |
|
Listed by |
GEAppliances.com or call |
|
Underwriters |
GE Answer Center® service, 800.626.2000. |
R |
Laboratories |
|
|