GE JVM1750DPWW, JVM1750DPCC, JVM1750DPBB Specification

GE JVM1750DPWW, JVM1750DPCC, JVM1750DPBB Specification

JVM1750DPWW/CC/BB

GE Spacemaker® Over-the-Range Microwave Oven

Dimensions and Installation Information (in inches)

Note: Requires 120V grounded outlet. Electrical receptacle must be located in cabinet above Spacemaker microwave oven. No additional wiring, venting or cabinet rebuilding necessary

in many cases. Complete detailed, easy-to-follow installation instructions and convenient full-size templates are packed with the Spacemaker microwave oven.

Important Information: When installing the Spacemaker microwave oven over a range, allow minimum of 2" from bottom of Spacemaker microwave oven to top of range backguard to allow for removal of light covers.

Ventilation Options: The Spacemaker microwave ovens are designed for adaptation to the following three types of ventilation:

Outside exhaust (vertical – as shown)

Outside exhaust (horizontal)

Recirculating (non-vented ductless – see Filter Kit drawing)

Installation Information: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

24-1/2

105° Door open

(without

obstruction)

66" MIN.

30"

Mounting

MIN.

height

width

from

required

floor

 

 

13"

 

MAX.

 

12"

 

MIN.

15-1/4

16-7/16

16-1/2 (rear)

29-7/8

Minimum distance from door hinge side to adjacent wall should equal 1/2-inch.

Exhaust outlet connects to 3-1/4" X 10" duct

Listed by

Underwriters

Laboratories

Specification Created 4/09

340150

JVM1750DPWW/CC/BB

GE Spacemaker® Over-the-Range Microwave Oven

Dimensions and Installation Information (in inches)

 

Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT. Read the

Optional Accessories (Available at additional cost)

following carefully.

 

Exhaust Connection: The hood exhaust has been designed to mate with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6" diameter duct

Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.

Maximum Duct Length: For satisfactory air movement, the total duct length of

3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 120 equivalent feet.

Elbows, Transitions, Wall and Roof Caps, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.

Duct

Equivalent Feet

A. Rectangular-To-round

 

Transition Adaptor

5 ft.

 

 

B. Wall Cap

40 ft.

 

 

C. 90° Elbow

10 ft.

 

 

D. 45° Elbow

5 ft.

 

 

E. 90° Elbow

25 ft.

 

 

F. 45° Elbow

5 ft.

 

 

G. Roof Cap

24 ft.

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

Filler Panel Kits

JX48BL–Black

JX48WH–White

When replacing a 36" or 42" range hood, this kit fills in the additional width to provide a custom built-in appearance. For installation between ­cabinets only; not

for end-of-cabinet installation. Each kit ­contains two 3"-wide filler panels.

Filter KitsJX81J– Recirculating Charcoal Filter KitTo be used when the Spacemaker microwave oven cannot be vented to the outside.

Listed by

Underwriters

Laboratories

Specification Created 4/09

340150