JVM1730DPWW/CC/BB
GE Spacemaker® Over-the Range Microwave Oven
Dimensions and Installation Information (in inches)
Note: Requires 120V grounded outlet. Electrical receptacle must be located in cabinet above Spacemaker microwave oven. No additional wiring, venting or cabinet rebuilding necessary
in many cases. Complete detailed, easy-to-follow installation instructions and convenient full-size templates are packed with the Spacemaker microwave oven.
Important Information: When installing the Spacemaker microwave oven over a range, allow minimum of 2" from bottom of Spacemaker microwave oven to top of range backguard to allow for removal of light covers.
Ventilation Options: The Spacemaker microwave ovens are designed for adaptation to the following three types of ventilation:
•Outside exhaust (vertical – as shown)
•Outside exhaust (horizontal)
•Recirculating (non-vented ductless – see Filter Kit drawing)
Installation Information: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.
24-1/2
105° Door open
(without
obstruction)
66" MIN. |
30" |
Mounting |
MIN. |
height |
width |
from |
required |
floor |
|
|
13" |
|
MAX. |
|
12" |
|
MIN. |
15-1/4
16-7/16
16-1/2 (rear)
29-7/8
Minimum distance from door hinge side to adjacent wall should equal 1/2-inch.
Exhaust outlet connects to 3-1/4" X 10" duct
Listed by
Underwriters
Laboratories
Specification Created 4/09 |
340146 |
JVM1730DPWW/CC/BB
GE Spacemaker® Over-the Range Microwave Oven
Optional Accessories (Available at additional cost)
Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
Exhaust Connection: The hood exhaust has been designed to mate with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6" diameter duct.
Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
Maximum Duct Length: For satisfactory air movement, the total duct length of
3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 140 equivalent feet.
Elbows, Transitions, Wall and Roof Caps, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
Filler Panel Kits
JX48BL–Black
JX48WH–White
When replacing a 36" or 42" range hood, this kit fills in the additional width to provide a custom built-in appearance. For installation between cabinets only; not
for end-of-cabinet installation. Each kit contains two 3"-wide filler panels.
Duct |
Equivalent Feet |
A. Rectangular-To-round |
5 ft. |
Transition Adaptor |
|
|
|
B. Wall Cap |
40 ft. |
|
|
C. 90° Elbow |
10 ft. |
|
|
D. 45° Elbow |
5 ft. |
|
|
E. 90° Elbow |
25 ft. |
|
|
F. 45° Elbow |
5 ft. |
|
|
G. Roof Cap |
24 ft. |
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.
Filter KitsJX81J– Recirculating Charcoal Filter KitTo be used when the Spacemaker microwave oven cannot be vented to the outside.
Listed by
Underwriters
Laboratories
Specification Created 4/09 |
340146 |