![](/html/05/05cb/05cbb310eaf98687c4f14fcf98f63b9925c6e061c635d8e7eaad7c16858f4be2/bg1.png)
GE Appliances
21-3/4"
Door open
16-13/32
66" MIN.
Mounting
height
from
floor
30"
MIN.
width
required
12
"
MIN.
Exhaust outlet
connects to
3-1/4" X 10" duct
15-1/4
16
29-7/8
JVM1660BH/CH/SH/WH – GE Spacemaker® Over-the-Range Microwave Oven
Dimensions (in inches)
Note: Requires 120V grounded outlet. Electrical receptacle must be located in
cabinet above Spacemaker microwave oven. No additional wiring, venting or
cabinet rebuilding necessary in many cases. Complete detailed, easy-to-follow
installation instructions and convenient full-size templates are packed with the
Spacemaker microwave oven.
Important Information: When installing the Spacemaker microwave oven
over a range, allow minimum of 2" from bottom of Spacemaker microwave
oven to top of range backguard to allow for removal of light covers.
Ventilation Options: The Spacemaker microwave ovens are designed for
adaptation to the following three types of ventilation:
• Outside exhaust (vertical – as shown)
• Outside exhaust (horizontal)
• Recirculating (non-vented ductless – see Filter Kit drawing)
Installation Information: This information is not intended to be used for
installing unit described. Before installing, consult installation instructions
packed with product/kit for current dimensional data.
Specification Created 3/04
34 010 6
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center
®
service, 800.626.2000.
![](/html/05/05cb/05cbb310eaf98687c4f14fcf98f63b9925c6e061c635d8e7eaad7c16858f4be2/bg2.png)
GE Appliances
JVM1660BH/CH/SH/WH – GE Spacemaker® Over-the-Range Microwave Oven
Optional Accessories (Available at additional cost)
Filler Panel Kits
JX48BL – Black
JX48WH – White
When replacing a
36" or 42" range hood,
this kit fills in the
additional width to
provide a custom
built-in appearance.
For installation
between cabinets only;
not for end-of-cabinet
installation. Each kit
contains two 3"-wide
filler panels.
Filter Kits
JX81A – Recirculating
Charcoal Filter Kit
To be used when the
Spacemaker microwave
oven cannot be vented
to the outside.
HOOD EXHAUST DUCT: Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard 3-1/4" x 10"
rectangular duct. If a round duct is required, a rectangular-to-round transition adaptor must be used.
Do not use less than a 6” diameter duct
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space
between studs, or wall should be prepared at the time it is constructed by leaving enough space between the
wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of 3-1/4" x 10" rectangular or
6" diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS,WALL AND ROOF CAPS, etc., present additional resistance to airflow and are
equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total
duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections.
The chart below shows the approximate feet of equivalent length of some typical ducts.
Duct Equivalent Feet
A. Rectangular-To-round 5 ft.
Transition Adaptor
B. Wall Cap 40 ft.
C. 90° Elbow 10 ft.
D. 45° Elbow 5 ft.
E. 90° Elbow 25 ft.
F. 45° Elbow 5 ft.
G. Roof Cap 24 ft.
Specification Created 3/04
34 010 6
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center
®
service, 800.626.2000.