JVM1640AJ/BJ/CJ/SJ/WJ – GE Spacemaker® Over-the-Range Microwave Oven
Dimensions (in inches)
Note: Requires 120V grounded outlet. Electrical receptacle must be
located in cabinet above Spacemaker microwave oven. No additional wiring, venting or cabinet rebuilding necessary in many cases. Complete detailed, easy-to-follow installation instructions and convenient full-size templates are packed with the Spacemaker microwave oven.
Important Information: When installing the Spacemaker microwave oven over a range, allow minimum of 2" from bottom of Spacemaker microwave oven to top of range backguard to allow for removal of light covers.
Ventilation Options: The Spacemaker microwave ovens are designed for adaptation to the following three types of ventilation:
• Outside exhaust (vertical – as shown)
• Outside exhaust (horizontal)
• Recirculating (non-vented ductless)
Installation Information: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
Specification Revised 1/04
34 0112
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at GEAppliances.com or call GE Answer Center® service, 800.626.2000.
GE Appliances
R
JVM1640AJ/BJ/CJ/SJ/WJ – GE Spacemaker® Over-the-Range Microwave Oven
Optional Accessories (Available at additional cost)
12" Filler Panel Kits JX41–Black JX40WH–White
15" Filler Panel Kits JX48BL–Black JX48WH–White
When replacing a 36" or 42" range hood, this kit fills in the additional width to provide a custom built-in appearance. For installation between cabinets only; not for end-of-cabinet installation. Each kit contains two 3"-wide filler panels.
Filter Kits JX81D–
Recirculating Charcoal Filter Kit
To be used when the Spacemaker microwave oven cannot be vented to the outside.
HOOD EXHAUST DUCT:
Outside ventilation requires a HOOD EXHAUST DUCT. Read the
following carefully.
EXHAUST CONNECTION:
The hood exhaust has been designed to mate with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6" diameter duct
REAR EXHAUST:
If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is con structed by leaving enough space between the wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH
: For satisfactory air movement, the total duct length of
3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS
, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
Duct
A. Rectangular-To-round
Equivalent Feet
5 ft.
Transition Adaptor
B. Wall Cap
C.
90° Elbow
D. 45° Elbow
E. 90° Elbow
F.
45° Elbow
G.
Roof Cap
40 ft.
10 ft.
5 ft.
25 ft.
5 ft.
24 ft.
-