GE JVM1630BK, JVM1630CK, JVM1630WK Specification

GE JVM1630BK, JVM1630CK, JVM1630WK Specification

JVM1630BK/CK/WK

GE Spacemaker® Over-the-Range Microwave Oven

Dimensions and Installation Information (in inches)

 

Note: Requires 120V grounded outlet. Electrical receptacle must be

 

located in cabinet above Spacemaker microwave oven. No additional

 

wiring, venting or cabinet rebuilding necessary in many cases. Complete

 

detailed, easy-to-follow installation instructions and convenient full-size

 

templates are packed with the Spacemaker microwave oven.

 

Important Information: When installing the Spacemaker microwave

 

oven over a range, allow minimum of 2” from bottom of Spacemaker

 

microwave oven to top of range backguard to allow for removal

 

of light covers.

 

Ventilation Options: The Spacemaker microwave ovens and

 

Spacemaker convection/microwave ovens are designed for

 

adaptation to the following three types of ventilation:

 

• Outside exhaust (Vertical – as shown)

21-3/4"

• Outside exhaust (horizontal)

Door open

• Recirculating (non-vented ductless – see Filter Kit drawing)

 

Installation Information: This information is not intended to be used for

29-7/8

installing unit described. Before installing, consult installation instructions

 

packed with product/kit for current dimensional data.

 

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

66" MIN. Mounting height from floor

30" MIN. width required

12"

MIN.

15-5/32

16-3/16

15-5/8

Exhaust outlet connects to 3-1/4" X 10" duct

Listed by Underwriters Laboratories

R

Specification Created 5/05

340126

JVM1630BK/CK/WK

GE Spacemaker

®

Over-the-Range Microwave Oven

 

 

Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.

Exhaust Connection: The hood exhaust has been designed to mate with a standard 3-1/4" x 1" rectangular duct. If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6" diameter duct.

Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.

Maximum Duct Length: For satisfactory air movement, the total duct length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 140 equivalent feet.

ELBOWS, TRANSITIONS, WALL AND ROOF CAPS: etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.

Optional accesories (Available at additional cost)

Filler Panel Kits JX48BL–Black JX48WH–White

When replacing a 36" range hood, this kit fills in the additional width to provide a custom built-in appearance. For installation between cabinets only; not for end-of-cabinet installation. Each kit contains two 3"-wide filler panels.

Filter Kits

JX81D–Recirculating Charcoal Filter Kit

To be used when the Spacemaker microwave oven cannot be vented to the outside.

Duct

Equivalent Feet

A. Rectangular-To-round

 

Transition Adaptor

5 ft.

B. Wall Cap

40 ft.

C. 90° Elbow

10 ft.

D. 45° Elbow

5 ft.

E. 90° Elbow

25 ft.

F. 45° Elbow

5 ft.

G. Roof Cap

24 ft.

R

Listed by Underwriters Laboratories

Specification Created 5/05

340126