JVM1490BH/CH/SH/WH
Over-the-Range Microwave Oven
Dimensions (in inches)
66" MIN.
Mounting
height
from
floor
30"
MIN.
width
required
Exhaust outlet
connects to
3-1/4" X 10" duct
16-13/32
(Rear)
15-3/8
24-1/2
16-19/32
29-7/8
Minimum distance from
door hinge side to adjacent
wall should equal 1/2-inch.
(without
obstruction)
13"
MAX.
12"
MIN.
GE Profile™ Spacemaker® Convection/Microwave Oven
Dimensions and Installation Information (in inches)
Note: Requires 120V grounded outlet. Electrical receptacle must be
located in cabinet above Spacemaker microwave oven. No
additional wiring, venting or cabinet rebuilding necessary in
many cases. Complete detailed, easy-to-follow installation
instructions and convenient full-size templates are packed with the
Spacemaker microwave oven.
Important Information: When installing the Spacemaker
microwave oven over a range, allow minimum of 2” from bottom
of Spacemaker microwave oven to top of range backguard to
allow for removal of light covers.
Ventilation Options: The Spacemaker microwave ovens and
Spacemaker convection/microwave ovens are designed for
adaptation to the following three types of ventilation:
• Outside exhaust (Vertical – as shown)
• Outside exhaust (horizontal)
• Recirculating (non-vented ductless – see Filter Kit drawing,
order JX81, JX81A or JX81B)r
Installation Information: This information is not intended to
be used for installing unit described. Before installing, consult
installation instructions packed with product/kit for current
dimensional data.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Specification Revised 8/07
Listed by
Underwriters
Laboratories
240270
JVM1490BH/CH/SH/WH
GE Profile™ Spacemaker® Convection/Microwave Oven
Dimensions and Installation Information (in inches)
Hood Exhaust Duct: Outside ventilation requires a HOOD EXHAUST DUCT. Read the
following carefully.
Exhaust Connection: The hood exhaust has been designed to mate with a standard
3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition
adaptor must be used. Do not use less than a 6" diameter duct
Rear Exhaust: If a rear or horizontal exhaust is to be used, care should be taken to
align exhaust with space between studs, or wall should be prepared at the time it is
constructed by leaving enough space between the wall studs to accommodate exhaust.
Maximum Duct Length: For satisfactory air movement, the total duct length of
3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 120 equivalent feet.
Elbows, Transitions, Wall and Roof Caps, etc., present additional resistance to airflow
and are equivalent to a section of straight duct which is longer than their actual physical
size. When calculating the total duct length, add the equivalent length of all transitions
and adaptors plus the lengths of all straight duct sections. The chart below shows the
approximate feet of equivalent length of some typical ducts.
Duct Equivalent Feet
A. Rectangular-To-round 5 ft.
Transition Adaptor
B. Wall Cap 40 ft.
C. 90° Elbow 10 ft.
D. 45° Elbow 5 ft.
E. 90° Elbow 25 ft.
F. 45° Elbow 5 ft.
G. Roof Cap 24 ft .
Optional Accessories (Available at additional cost)
Filler Panel Kits
JX46BL–Black
JX46WH–White
When replacing a 36" or
42" range hood, this kit fills
in the additional width to
provide a custom built-in
appearance. For installation
between cabinets only; not
for end-of-cabinet installation.
Each kit contains two 3"-wide
filler panels. Two kits are needed
for a 42" opening.
Filter KitsJX81A–
Recirculating Charcoal
Filter Kit
To be used when
the Spacemaker
microwave oven
cannot be vented
to the outside.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Specification Revised 8/07
Listed by
Underwriters
Laboratories
240270