JVM1460WA—GE Profile™ SpacemakerXL 1.4 Cu. Ft. Microwave Oven
Dimensions (in inches)
66" MIN. |
|
|
|
Mounting |
30" |
MIN. |
Exhaust outlet |
height |
width |
required |
|
from floor |
|
|
connects to |
|
|
|
3-1/4" X 10" duct |
|
|
|
|
|
12" |
|
|
MAX. |
|
|
15 |
|
21-3/4" |
16-1/2 |
|
15-3/4 |
||
Door open |
||
|
Note: Requires 120V grounded outlet. Electrical receptacle must be located in cabinet above SpacemakerXL microwave oven. No additional wiring, venting or cabinet rebuilding necessary in many cases. Complete detailed, easy-to-follow installation instructions and convenient full-size templates are packed with the SpacemakerXL microwave oven.
Important Information: When installing the SpacemakerXL microwave oven over a range, allow minimum of 2" from bottom of SpacemakerXL microwave oven to top of range backguard to allow for removal of light covers.
Ventilation Options: The SpacemakerXL microwave ovens are designed for adaptation to the following three types of ventilation:
•Outside exhaust (vertical—as shown)
•Outside exhaust (horizontal)
•Recirculating (non-vented ductless—see Filter Kit drawing)
Installation Information: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
For answers to your Monogram,®
GE Profile Performance Series,™
GE Profile™ or GE appliance questions, call
GE Answer Center® service, 800.626.2000.
Revised 2/99
R
Listed by Underwriters Laboratories
TM
JVM1460WA—GE Profile™ SpacemakerXL 1.4 Cu. Ft. Microwave Oven
Optional Accessories (Available at additional cost)
12" Filler Panel Kits
JX40AL–Almond
JX41–Black
JX40WH–White
15" Filler Panel Kits
JX46BL–Black
JX46AL–Almond
JX46WH–White
When replacing a 36" or 42" range hood, this kit fills in additional width to provide a custom built-in appearance. For installation between only; not for end-of-cabinet Each kit contains two 3"-wide Two kits are needed for a 42"
3/8" |
19 |
depth |
30 |
JX22SS–Stainless Steel Decorative Panel Kit
When replacing a Hi/Low range with a SpacemakerPlus™ microwave/convection oven or Spacemaker XL1400 over a range model, this panel kit fills in the area between the microwave and range left by the Hi/Low model.
Revised 2/99
Kit
the microwave vented
Kit
the
vented
HOOD EXHAUST DUCT
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard 3-1/4” x 10” rectangular duct.If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6” diameter duct
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs,or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of 3-1/4” x 10” rectangular or 6” diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS,WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
|
Duct |
|
Equivalent Feet |
|
|
|
|
||
|
A. Rectangular-To-round |
|
5ft. |
|
|
Transition Adaptor |
|
|
|
|
B. Wall Cap |
|
40ft. |
|
|
C. 90° Elbow |
|
10ft. |
|
|
|
|
|
|
|
D. 45° Elbow |
|
5ft. |
|
|
|
|
|
|
|
E. 90° Elbow |
|
25ft. |
|
|
F. 45° Elbow |
|
5ft. |
|
|
G. Roof Cap |
|
24ft. |
|
|
|
|
|
|
|
|
|
|
|
For answers to your Monogram,®
GE Profile Performance Series,™
GE Profile™ or GE appliance questions, call
GE Answer Center® service, 800.626.2000.
Listed by
Underwriters
R Laboratories