TM
JP989WD/BD/CD/TD – GE Profile 30" Downdraft Electric Cooktop
Built-In Downdraft Cooktops Dimensions (in inches)
29-7/8
6
28-3/4
Cutout Dimensions (in inches)
20-5/8
28-7/8
25
1-7/8"
MIN. Required*
*U.L. Requirement.
Note: A 6" minimum spacing to adjacent side wall is required
Specification Revised 10/04
Cabinet Dimensions (in inches)
9
CL 4
16 |
10-1/2 |
|
|
|
20 |
Receptacle Location
nstall an approved junction box within shaded area shown in diagram. Junction box must be at least 10-1/2" below top of cabinet.
KW Rating
240V
8.8
208V 6.7
Wall Installation
Wall installations require 25" countertop depth. When cabinet is flush against the wall, the fan housing can be rotated to the horizontal position for direct venting through rear wall. Make a
countertop cutout in the range cabinet according to unit dimensions and installation type. Duct hole is positioned in back of cabinet for through-the-wall ducting. Requires special offset adapter JXRW89.
Peninsula or Island Installation
For peninsula/islands a minimum 26" countertop depth is suggested. Blower should be in vertical position. Island or peninsula cabinets may require adjustment in cutout depth and/or location within the width dimensions. Duct hole is positioned in bottom of cabinet for island or peninsula installation.
Slab Installation
For peninsula or island installation and rear wall ducting, 6" PVC duct or locally approved piping should be used if installing under a poured concrete slab.
Installation Information: Before installing, consult installation instructions packed with product for current dimensional data.
Note: Electrical cable is not supplied with unit.
These cooktops are U.L. approved for indoor use only.
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profi le or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000
220945
TM
JP989WD/BD/CD/TD – GE Profile 30" Downdraft Electric Cooktop
Venting Options
Inside Wall
Through Roof
Between the Floor Joists
Specification Revised 10/04
Direct to Outside Straight Duct
Downward Venting (in inches) Rear Wall Venting (in inches)
6-1/8 |
9-1/8 |
|
18-3/4 |
||
|
||
10-1/8 |
|
Installing the Ductwork
Use galvanized or aluminum duct in 6" round or 3-1/4" x 10" size, or combination of both. PVC duct or locally approved piping should be used if installing under a poured concrete slab. Local building code must be followed in specifying type and schedule of all duct used.
|
Listed by |
|
Underwriters |
|
Laboratories |
|
For answers to your Monogram,® GE Profi le or |
Through the Cabinet Toe Space |
GE® appliance questions, visit our website at |
ge.com or call GE Answer Center® service, |
|
|
800.626.2000 |
220945