GE JP989TK, JP989KK, JP989BK Specification

R
JP989TK/KK/BK
25
1-7/8"
MIN. Required*
20-5/8
Cut-out Dimensions (in inches)
28-7/8
*U.L. Requirement.
40
Long
20
9
4
10-1/2
16
C L
Cabinet Dimensions (in inches)
22
21-7/8 29-7/8
28-3/420-1/2
3-1/4 x 10
2
22
21-7/8 29-7/8
28-3/420-1/2
3-1/4 x 10
2
GE Profile™ 30" Downdraft Electric Cooktop
8.8
6.7
Wall Installation: Wall installations require 25” countertop cabinet is flush against the wall, the fan housing can be rotated to the
Dimensions and Installation Information
KW Rating
240V
208V
horizontal position for direct through rear wall. Make a countertop cabinet according to unit dimensions and installation type. Duct hole is positioned in back of cabinet for through-the­wall ducting. Requires special offset adapter JXRW89.
Peninsula or Island Installation: For peninsula/islands a minimum 26”
countertop be in vertical position. Island or peninsula cabinets may require adjustment in cutout depth and/or location within the width dimensions. Duct hole is positioned in bottom of cabinet for island or peninsula installation.
Slab Installation: For peninsula or island installation and rear wall ducting, 6” PVC duct or locally approved piping
should be used if installing under a poured concrete slab.
Receptacle Location: Install an approved junction box
within shaded area shown in diagram. Junction box must be at least 10-1/2" below top of cabinet.
Installation Information: Before installing, consult installation instructions, packed with product, for current dimensional data. Note: Electrical cable is not supplied with unit.
These cooktops are approved for indoor use only.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
depth. When
venting
cutout in the range
depth is suggested. Blower should
*Note: A 6" minimum spacing to adjacent side wall is required
Dimension and installation information are shown in inches.
Listed by Underwriters Laboratories
Specification Created 11/04
220974
R
JP989TK/KK/BK
Venting Options
Through Cabinet Toe Space
Inside
Wall to Roof Direct to Outside
Between Floor Joist
9-1/8
10-1/8
18-3/4
6-1/8
GE Profile™ 30" Downdraft Electric Cooktop
Dimensions and Installation Information
Installing the Ductwork: Use galvanized
or aluminum duct in 6” round or 3-1/4” x 10” size, or combination of both. PVC duct
or locally approved piping should be used if installing under a poured concrete slab.
Local building code must be followed in specifying type and schedule of all duct used.
Note: Ductwork must be vented to outside. Do not vent into a wall, ceiling, crawlspace, attic or any concealed space. Always use an appropriate roof or wall cap with damper.
Laundry-type wall caps should never be used. For maximum efficiency use the
shortest and straightest duct run possible, with as few fittings as possible. For satisfactory should not exceed 100 feet equivalent length. Refer to the table of equivalent lengths (shown in installation instructions) for various duct configurations.
performance the duct run
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
Rear Wall VentingDownward Venting
Dimension and installation information are shown in inches.
Listed by Underwriters Laboratories
Specification Created 11/04
220974
Loading...
+ 1 hidden pages