GE JP389, JP389WJ, JP389BJ Specifications

Page 1
JP389WJ/BJ – GE Select-Top™ Modular Downdraft Cooktop
Specification Created 6/04
321118
GE Appliances
Built-In Downdraft Modular Cooktop Dimensions (in inches)
Built-In Downdraft Modular Cooktop Cabinet Dimensions (in inches)
Receptacle Location: Install an approved
junction box within shaded area shown in diagram. Junction box must be at least 10-1/2" below top of cabinet.
Note: These cook tops are U.L. approved for indoor use only.
Installation Information: Before installing, consult installation instructions packed with product for current dimensional data.
10-1/2
28-7/8
27-1/2
29-7/8
12-1/
4
6
20
9
4
10-1/2
16
C L
Cabinet Dimensions (in inches)
R
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™ or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center
®
service, 800.626.2000.
20
9
4
10-1/2
16
C L
Cabinet Dimensions (in inches)
21-9/16
3
19
3-1/4
x 10
20-1/2
28-7/8
27-1/2
29-7/8
12-1/
4
6
Cooktop Dimensions (in inches)
Page 2
JP389WJ/BJ – GE Select-Top™ Modular Downdraft Cooktop
Specification Created 6/04
321118
GE Appliances
GE Appliances
Cutout Dimensions (in inches)
Preparing the Cabinet for Installation
Note: In some cabinets, the sides may need to be scooped or cut down 2" as shown and the corner
braces removed in order to accommodate the cooktop.
Wall Installation: Wall installations require 25" countertop depth. When cabinet is flush against the wall, the fan housing can be rotated to the horizontal position for direct venting through rear wall. Make a countertop cutout that is centered in the range cabinet according to unit dimensions and installation type. Duct hole is positioned in back of cabinet for through-the-wall ducting.
Peninsula or Island Installation: For peninsula or island installation, a minimum 26" countertop depth is suggested. Blower should be in vertical position. Island or peninsula cabinets may require adjustment in cutout depth and/or location within the width dimensions. Duct hole is positioned in bottom of cabinet for island or peninsula installation.
Slab Installation: For peninsula or island installation and rear wall ducting, PVC duct or locally­approved piping should be used if installing under a poured concrete slab.
Installing the Ductwork: Use minimum 26-gauge galvanized or 24-gauge aluminum duct in 6" round or 3-1/4" x 10" size, or combination of both. PVC duct or locally approved piping should be used if installing under a poured concrete slab.
25
1-7/8"
MIN. Required*
20-5/8
Cut-out Dimensions (in inches)
28-7/8
*U.L. Requirement.
Note: A 6" minimum spacing to adjacent side wall is required
1-7/8"
MIN. Required*
20-5/8
Cut-out Dimensions (in inches)
28-7/8
9-3/8
15-3/4
7-9/16
Downward venting
(in inches)
2" Approx.
5" Approx.
for European
cabinets
28-7/8
9-3/8
7-9/16
Downward venting
(in inches)
25
1-7/8"
MIN. Required*
20-5/8
Cut-out Dimensions (in inches)
28-7/8
*U.L. Requirement.
Note: A 6" minimum spacing to adjacent side wall is required
9-3/8
9-3/8
15-3/4
7-9/16
Rear wall venting (in inches)
Downward venting
(in inches)
R
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™ or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center
®
service, 800.626.2000.
Page 3
JP389WJ/BJ – GE Select-Top™ Modular Downdraft Cooktop
Specification Created 6/04
321118
GE Appliances
Venting Options
40
Long
Venting Options
Inside Wall
Through Roof
Direct to Outside
Straight Duct
Direct to Outside
Straight Duct
40
Long
Venting Options
Inside Wall
Through Roof
Direct to Outside
Straight Duct
Between the Floor Joists
Direct to Outside
Straight Duct
Through the Cabinet Toe Space
Note: Ductwork must be vented to outside. Do not vent into a wall, ceiling, crawlspace, attic or
any concealed space. Always use an appropriate roof or wall cap with damper. Laundry-type wall caps should never be used. For maximum efficiency use, the shortest and straightest duct run possible, with as few fittings as possible. For satisfactory per formance, the duct run should not exceed 100 feet equivalent length. Refer to the table of equivalent lengths for various duct configurations.
Installation Information: Before installing, consult installation instructions packed with product for current dimensional data.
Note: Check local codes for required breaker size
R
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™ or GE appliance questions, visit our website at GEAppliances.com or call GE Answer Center
®
service, 800.626.2000.
KW Rating
240V
8.0
Breaker Size
40 Amps
Page 4
JP389WJ/BJ – GE Select-Top™ Modular Downdraft Cooktop
Specification Created 6/04
321118
GE Appliances
M
E
D
M
E
D
JP389WB/BD.EPS
Features and Benefits
• 30" Dual Modular Cooktop
• Infinite Heat Rotary Controls
• Powerful Downdraft Venting System
• 3-Speed Fan
• Heating Element “ON” Indicator Light
• Porcelain-Enameled Cooktop
• Optional Modules Available At Additional Cost
• Model JP389BJ – Black on black
• Model JP389WJ – White on white
Models
Optional modules available at additional cost JP389WJ JP389BJ
Calrod
®
modules
JXDC44RWH JXDC43RBL
Ribbon modules
JXDR50VW JXCDR50VB
Grill modules
JXDL44N JXDL44N
Griddle Accessory
JXDD44R JXDD44R
Grill Cover
JXDM3 JXDM2