JNM3184
GE® 1.8 cu. ft. Over-the-Range Microwave Oven with Recirculating Venting
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
NOTE: Requires 120V grounded outlet. Electrical receptacle must be located in cabinet above microwave oven. No additional wiring, venting or cabinet rebuilding necessary in many cases. Complete detailed, easy-to-follow installation instructions and convenient full-size templates are packed with the microwave oven.
IMPORTANT INFORMATION: When installing the microwave oven over a range, allow minimum of 2" from bottom of microwave oven to top of range backguard to allow for removal of light covers.
VENTILATION OPTIONS: The Spacemaker microwave ovens are designed for adaptation to the following three types of ventilation:
•Outside exhaust (vertical – as shown)
•Outside exhaust (horizontal)
•Recirculating (non-vented ductless – see Filter Kit drawing)
INSTALLATION INFORMATION: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
Minimum distance from door hinge side to adjacent wall should equal 1/2"
23-7/16"
95° Door open
(without obstruction)
66" MIN. Mounting height from floor
30"
MIN. width
required Exhaust outlet connects to
3-1/4" x 10" duct
13"
MAX.
12"
MIN.*
15-7/8"
16-7/16"
(rear)
15-7/12"
*Maximum depth with JX15
Bump Out Kit is 16"
Bump Out Kit sold separately.
For answers to your Monogram, GE Café™, GE Profile™ or GE Appliances |
|
product questions, visit our website at geappliances.com or call |
|
GE Answer Center® Service, 800.626.2000. |
Specification Created 10/20 |
JNM3184
GE® 1.8 cu. ft. Over-the-Range Microwave Oven with Recirculating Venting
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
HOOD EXHAUST DUCT: Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
OPTIONAL ACCESSORIES (AVAILABLE AT ADDITIONAL COST)
EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6" diameter duct.
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 120 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
DUCT |
EQUIVALENT FEET |
|
A. Rectangular-To-round |
5 ft. |
|
Transition Adaptor |
||
|
||
|
|
|
B. Wall Cap |
40 ft. |
|
|
|
|
C. 90° Elbow |
25 ft. |
|
|
|
|
D. 45° Elbow |
5 ft. |
|
E. 90° Elbow |
10 ft. |
|
|
|
|
F. 45° Elbow |
5 ft. |
|
|
|
|
G. Roof Cap |
24 ft. |
FILTER KIT WB06X10608 RECIRCULATING CHARCOAL FILTER KIT
To be used when the microwave oven cannot be vented to the outside.
For answers to your Monogram, GE Café™, GE Profile™ or GE Appliances |
|
product questions, visit our website at geappliances.com or call |
|
GE Answer Center® Service, 800.626.2000. |
Specification Created 10/20 |