JNM3184
95°
Door open
(without obstruction)
23-7/16"
Minimum distance from
door hinge side to
adjacent wall should
equal 1/2"
66" MIN.
Mounting
height
from
floor
30"
MIN.
width
required
Exhaust outlet
connects to
3-1/4" x 10" duct
13"
MAX.
12"
MIN.*
16-7/16"
(rear)
15-7/8"
29-7/8"
15-7/12"
*Maximum depth
with JX15
Bump Out Kit is 16
"
Bump Out Kit
sold separately.
GE® 1.8 cu. ft. Over-the-Range Microwave Oven with Recirculating Venting
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
NOTE: Requires 120V grounded outlet. Electrical receptacle
must be located in cabinet above microwave oven. No
additional wiring, venting or cabinet rebuilding necessary in
many cases. Complete detailed, easy-to-follow installation
instructions and convenient full-size templates are packed
with the microwave oven.
IMPORTANT INFORMATION: When installing the
microwave oven over a range, allow minimum of 2" from
bottom of microwave oven to top of range backguard to allow
for removal of light covers.
VENTILATION OPTIONS: The Spacemaker microwave
ovens are designed for adaptation to the following three types
of ventilation:
• Outside exhaust (vertical – as shown)
• Outside exhaust (horizontal)
• Recirculating (non-vented ductless – see Filter Kit drawing)
INSTA L LATIO N I NFO R MATION : This information is
not intended to be used for installing unit described. Before
installing, consult installation instructions packed with
product/kit for current dimensional data.
For answers to your Monogram, GE Café™, GE Profile™ or GE Appliances
product questions, visit our website at geappliances.com or call
GE Answer Center® Service, 800.626.2000.
Specification Created 10/20
JNM3184
GE® 1.8 cu. ft. Over-the-Range Microwave Oven with Recirculating Venting
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
HOOD EXHAUST DUCT: Outside ventilation requires a HOOD
EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate
with a standard 3-1/4" x 10" rectangular duct. If a round duct is required, a
rectangular-to-round transition adaptor must be used. Do not use less than a
6" diameter duct.
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should
be taken to align exhaust with space between studs, or wall should be prepared
at the time it is constructed by leaving enough space between the wall studs to
accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct
length of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed
120 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present
additional resistance to airf low and are equivalent to a section of straight
duct which is longer than their actual physical size. When calculating the total
duct length, add the equivalent length of all transitions and adaptors plus the
lengths of all straight duct sections. The chart below shows the approximate
feet of equivalent length of some typical ducts.
OPTIONAL ACCESSORIES (AVAILABLE AT ADDITIONAL COST)
FILTER KIT
WB06X10608
RECIRCULATING
CHARCOAL FILTER KIT
To be used when the
microwave oven cannot
be vented to the outside.
DUCT EQUIVALENT FEET
A. Rectangular-To-round
Transition Adaptor
B. Wal l Ca p 40 ft.
C. 90° Elbow 25 ft.
D. 45° Elbow 5 ft.
E. 90° Elbow 10 ft.
F. 45° Elbow 5 ft.
G. Roof Cap 24 ft.
5 ft.
For answers to your Monogram, GE Café™, GE Profile™ or GE Appliances
product questions, visit our website at geappliances.com or call
GE Answer Center® Service, 800.626.2000.