JNM3163RJ
95°
Door open
(without obstruction)
23-7/16"
Minimum distance from
door hinge side to
adjacent wall should
equal 1/2"
66" MIN.
Mounting
height
from
floor
30"
MIN.
width
required
Exhaust outlet
connects to
3-1/4" x 10" duct
13"
MAX.
12"
MIN.*
16-7/16"
(rear)
15-7/8"
29-7/8"
15-7/12"
*Maximum depth
with JX15
Bump Out Kit is 16
"
Bump Out Kit
sold separately.
GE® 1.6 cu. ft. Over-the-Range Microwave Oven with Recirculating Venting
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
Note: Requires 120V grounded outlet. Electrical receptacle must
be located in cabinet above microwave oven. No additional wiring,
venting or cabinet rebuilding necessary in many cases. Complete
detailed, easy-to-follow installation instructions and convenient
full-size templates are packed with the microwave oven.
IMPORTANT INFORMATION: When installing the microwave
oven over a range, allow minimum of 2" from bottom of microwave
oven to top of range backguard to allow for removal of light covers.
VENTILATION OPTIONS: The microwave ovens are designed for
adaptation to the following three types of ventilation:
• Outside exhaust (vertical – as shown)
• Outside exhaust (horizontal)
Recirculating (non-vented ductless – see Filter Kit drawing)
INSTAL L ATION IN F O RMATION : This information is not
intended to be used for installing unit described. Before installing,
consult installation instructions packed with product/kit for
current dimensional data.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.
Listed by
Underwriters
Laboratories
Speci fication Revised 5/18
JNM3163RJ
GE® 1.6 cu. ft. Over-the-Range Microwave Oven with Recirculating Venting
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
HOOD EXHAUST DUCT: Outside ventilation requires a HOOD EXHAUST
DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate with a
standard 3-1/4" x 10" rectangular duct. If a round duct is required, a rectangularto-round transition adaptor must be used. Do not use less than a 6" diameter duct.
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be
taken to align exhaust with space between studs, or wall should be prepared at the
time it is constructed by leaving enough space between the wall studs to
accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length
of 3-1/4" x 10" rectangular or 6" diameter round duct should not exceed 120
equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional
resistance to airflow and are equivalent to a section of straight duct which is longer
than their actual physical size. When calculating the total duct length, add the
equivalent length of all transitions and adaptors plus the lengths of all straight
duct sections. The chart below shows the approximate feet of equivalent length
of some typical ducts.
DUCT EQUIVALENT FEET
A. Rectangular-To-round
Transition Adaptor
B. Wal l Cap 40 ft.
C. 90° Elbow 10 ft.
D. 45° Elbow 5 ft.
E. 90° Elbow 25 ft.
F. 45° Elbow 5 ft.
G. Roof Cap 24 ft.
5 ft.
OPTIONAL ACCESSORIES (AVAILABLE AT ADDITIONAL COST)
FILTER KIT JX81C–
RECIRCULATING
CHARCOAL FILTER KIT
To be used when the
microwave oven cannot
be vented to the outside.
For answers to your Monogram, GE Café™ Series, GE Profile™ Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center® Service, 800.626.2000.