Before You Begin
Read these instructions carefully and completely.
• IMPORTANT-save these
instructions for local inspector's use.
• IMPORTANT-observe all
governing codes and ordinances.
• Note to Installer--Be sure to leave these
instructions with the consumer.
• Note to Consumer--Keep these
instructions for future reference.
Parts Included
(Appearance will vary)
Screws For Installation
(8-18 x .750 flat head
Phillips wood screws)
27" (68.6 cm)
Metal Bottom Trim
• Proper installation is the responsibility
of the installer and product failure due
to improper installation is NOT covered
under warranty.
• NOTE--This appliance must be properly
grounded.
•ATTENTION INSTALLER
All electric wall ovens must be hard wired
(direct wired) into an approved junction
box. A plug and receptacle is NOT permitted
on these products.
Materials Needed
Wire Nuts
Strain Relief Clamp Junction
for 1/2" conduit Box
WB07T10578 - Black
WB07T10579 - SS
Optional 27" (68.6 cm)
Metal Bottom Trim Assembly
(on some models or can be
purchased separately)
31-10647-3 11-07JR
30" (76.2 cm)
Metal Bottom Trim
Assembly
Tools Needed
1/8" (3 mm) Drill Bit and
Electric or Hand Drill
36" (91 cm)
of String
Phillips
Screwdriver
Installation instructions
PORTANT SAFETY I ST CTIONS
For Your Safety
• Be sure your oven is installed properly by
a qualified installer or service technician.
• Be sure the oven is securely installed in a
cabinet that is firmly attached to the house
structure. Weight on the oven door could
cause the oven to tip and result in injury.
Never allow anyone to climb, sit, stand or
hang on the oven door.
• Make sure the cabinets and wall
coverings around the oven can withstand
the temperatures (up to 200°F [93.3°C])
generated by the oven.
WARNING: The electrical
power to the oven supply line
must be shut off while line
connections are being made. Failure
to do so could result in serious injury
or death.
lectrical
Requirements
This appliance must be supplied with the proper
voltage and frequency, and connected to an
individual, properly grounded branch circuit,
protected by a circuit breaker or fuse. See the
rating plate located on the oven frame to determine
the rating of the product. Use the chart below to
determine the minimum recommended dedicated
circuit protection.
Recommended
KW Rating KW Rating Circuit Size
240V 208V (Dedicated)
<4.8 KW <4.1 KW 20Amp
4.9 KW-7.2 KW 4.3 KW-6.2 KW 30 Amp
7.3 KW-9.6 KW 6.3 KW-8.3 KW 40 Amp
9.7 KW-12.0 KW 8.4 KW-10.4 KW 50 Amp
lectrical
Requirements cont.
Rating plate is located on oven side trim,
side front frame or lower front frame.
Rating Plate
Location
We recommend you have the electrical wiring
and hookup of your oven connected by a qualified
electrician. After installation, have the electrician
show you where your main oven disconnect is
located.
Check with your local utilities for electrical codes
which apply in your area. Failure to wire your oven
according to governing codes could result in a
hazardous condition. If there are no local codes,
your oven must be wired and fused to meet the
requirements of the National Electrical Code,
ANSI/NFPA No. 70-Latest Edition. You can
get a copy by writing:
National Fire Protection Association
Batterymarch Park
Quincy, MA 02269
Effective January 1, 1996, the National
Electrical Code requires that new, but not existing,
construction utilize a four-conductor connection to
an electric oven. When installing an electric oven
in new construction, a mobile home, recreational
vehicle or an area where local codes prohibit
grounding through the neutral conductor,
follow the instructions in the section on NEW
CONSTRUCTION AND FOUR-CONDUCTOR
BRANCH CIRCUIT CONNECTION.
You must use a three-wire, single-phase A.C.
208Y/120 Volt or 240/120 Volt, 60 hertz electrical
system. If you connect to aluminum wiring,
properly installed connectors approved for
use with aluminum wiring must be used.
2
Insta ion instructions
Pre-lnstallation
ALL INSTALLATION INFORMATION
ON THE FOLLOWING PAGES IS TO
BF USED FOR SINGLE AND DOUBLE
OVEN INSTALLATION!
Remove packaging materials.
Check behind hinges and under
false bottom. Remove labels on the
outside of the door, plastic on trims
and panel, all tape around the oven,
and any shipping screws securing
the oven to the base pad.
__ =
Oven Racks
_ iterature
Pack
Chec ist
Door removal is not a requirement for
installation of the product, but is an
added convenience. To remove the door:
[_ Open the oven door as far as it will go.
Push both hinge Hinge
locks down toward ,_I_:'_L Position
the door frame, Hinge"I_
to the unlocked s_ot_.d
position. This may
require a flat blade
screwdriver. Arm
[_ DO NOT LIFT THE DOOR
[_ Place hands on both sides of "_
[_ ift door up and
the door, and close the oven 11_
door to the removal position, t_/
which is most of the way closed, t_'/
out until the
hinge arms
clear the slots.
_ :,,_ Unlocked
Hinge
Open oven door and remove literature
pack and oven racks.
Remove Installation Instructions from
literature pack and read them carefully
before you begin.
Be sure to place all literature, Owner's
Manual, Installations, etc. in a safe place
for future reference.
Hinge Clears Slot
NOTE: The oven door is very heavy. Be sure
you have a firm grip before lifting the oven
door off the hinges, Use caution once the
door is removed. Do not lay the door on its
handle. This could cause dents or scratches.
Place the oven on a table or platform
even with the cutout opening. (Platform
must support 150 Ibs. [68 Kg] single,
275 Ibs. [124 Kg] double.)
Remove the bottom trim from the top
of the oven. It will be installed at the end
of the installation process. The trim is
wrapped separately and taped to
the top of the unit.
3
Installation instructions
Cutout for 27" (68.6c )Single
Ovens on y
For JKS10, JKP30, JKP70, PK916, ZEK938 models only.
Max. from the
Cabinet_ _sk !_ Junction Box
27" (68.6 cm) i
Cutout Width /_
25" (63.5 cm)
Allow 1" (2.8 era)
for overlap of
oven over side
edges of cutout
2" x 4"
(Scmx tOcm)
0¥
runners level
with bottom
of cutout
20" (50.8 era)
Allow a minimum
ciearance°f20" (50.8teCta),41 _for overlap of
corners, drawers, wails, bottom
etc. when door is open of cutout'_"'_--_
a_jacen, oven top and
Min. j ,,: ,,
25 114" (64.1 "!-'
Max.
" Allow"
1" (2.5 cm)
minimum for
5" (12.7 cm)
left or right
I
/ Location
Cutout
Height 22" (55.9 cm)
27 5/8" Min. above
(70.2 cm) Min. base rail
28 118" I
access from
Box Location -
adjacent cabinet
Recommended may be required
cutout location
from Roor 32 1/2"
(82.6 cm)
uilt-ln
Cabinet Width
Recommended
Cutout Location
from Floor
Cutout Depth
Cutout Width
Cutout Height
NOTE: if the cabinet does not
have a front frame and the sides
are less than 3/4" (1.9 cm) thick,
shim both sides equally to
establish the cutout width.
27" (68.8 cm)
32 1/2" (82.6 cm)
23 1/2"
(59.7 cm) Min.
25" (63.5 cm) Min.
25 1/4" (64.1 cm) Max.
27 5/8" (70.2 cm) Min.
28 1/8" (71.4 cm) Max.
If the cabinet does not have a solid bottom,
two braces or runners must be installed
level with the bottom of the cutout to
support the weight of the oven. For
single ovens, the runners and braces
must support 150 Ibs (68 Kg).
NOTE: If marks, blemishes or the
cutout opening are visible above the
installed oven, it may be necessary to
add wood shims under the runners and
front trim until the marks or opening
are covered,
2" x 4" (5 cmx tO cm) or
equivalent runners love|
with bottom of cutout
T
24"
(61cm)
1
I-'_- 18" (45.7 cm) "-_1
"_ 27" (68,6 cm) "_
These ovens are not approved for
stackable installations.
4
Cutoutfor 27"(68.6
Ovensonly
For JKP35, JKP55, JKP75, PK956, ZEK958 models only.
Allow 1" (2.5 cm)
for overlap of
oven over side
edges of cutout
20" (50.8
--_ j°s-
Allow a minimum
of 20" (50.8 cm)
for clearance to
adjacent corners,
drawers, walls, etc.
when door is open
Installation instructions
5"
(12.7 cm)
Max. from
the left or
Cabinet right
(68.6 cm) _
Cutout
5" (63.5 cm) Min.
25 1/4" i
i Junction Box
__ Location
(s4.1cm)M_,
icut°ut Above
iHeight base rail
i49 11116"
i(126.2 cm) IVlin.
150118"
i(127.3 cm) Max.
.... Ailo_vI"
(2,5 cm) for
overlap of oven from floor 13 114"
top and bottom_ (33.7 cm)
of cutout
Recommended
cutout location
(111.8 cm)
Min.
Cabinet Width
27" (68.6 cm)
Recommended
Cutout Location
from Floor
Cutout Depth
Cutout Width
13 1/4" (33.7 cm)
23 5/8" (60 cm) Min.
25" (63.5 cm) Min.
25 114" (64.1 cm) Max.
Cutout Height
49 11116" (126.2 cm) Min.
50 1/8" (127.3 cm) Max.
NOTE: If the cabinet does
not have a front frame and
the sides are less than 314"
(1.9 cm) thick, shim both
sides equally to establish
the cutout width.
if the cabinet does not have a solid bottom,
two braces or runners must be installed to
support the weight of the oven. For double
ovens, the runners and braces must
support 300 Ibs (135 Kg).
NOTE: If marks, blemishes or the
cutout opening are visible above the
installed oven, it may be necessary to
add wood shims under the runners and
front trim until the marks or opening
are covered.
-- 2" x 4"
(ScmxtOcm)
or equiva|ent
ruuners level
with bottom
of cutout
Suitable
Bracing
to Support
Runners
Over Centerline
of Cabinet
5
Installation instructions
Cutout for 27" (68.6c_)Single Built-in
Ovens only Under Counter
For JKS10, JKP30, JKPT0, PK916, ZEK938 models only.
Gas or electric cooktops may
be installed over this oven.
See cooktop installation
instructions for cutout size.
See label on top of oven for
approved cooktop models.
\
25" (63.5 cm)
240V / 208V
Junction Box 5"
Location (12.7 cm)
Max. from the
left or right
side
Gas and electrical connections
for gas cooktop must be located
in an adjacent accessible
location to the right.
Top and/or side fillers
may be necessary
if unit is positioned
between existing
cabinets. Be sure
they are attached
securely, since they
will anchor the oven
in the cabinet.
_25" (63.5 cm) Min.
25 1/4" (64.1cm) Max.
27 5/8" (70.2 cm) Min.
28 1/8" (71.4 cm) Max.
_J J
Allow
I"
(2.5 cm)
unit overlap top _,
bottom of
oven, 1" (2.5 cm)
unit overlap side
edges
22" (55.9 cm) Min.
Above Support
Platform
4"(10.2 cm)
Typical
Toekick
36" (91.4 cm)
Typical
Countertop
Height
MUST SUPPORT 150 LBS. (68 Kg)
be installed under the specific models I_t
i NOTE: This oven is only approved to I_t
JJJ
6
Cabinetry
for 27" (68.6c_)Single or
uilt-ln Ovens only- Over a
Drawer
For JKS10, JKP30, JKP35, JKP55, JKPT0, JKP75, PK916, PK956, ZEK938,
ZEK958 models only.
Single 27" (68.6 cm)
Oven Over
a Warming Drawer
Anti-Tip Block Against
Rear Wall Per Warming
Drawer Requirement
2" (5.1 cm)
Min.
Per
Warming
Drawer
Requirement J
1" (2.5 cm) Min. Above Toekick or
Adjust to Oven Installation Height
NOTE: Additional clearances between cutouts
may be required. Check to be sure the oven
supports above the Warming Drawer location
do not obstruct the required interior depth and
height.
NOTE: Install the
oven only with
specific models
listed on the label
located on top of
the oven.
Double 27" (68.6 cm)
Oven Over
a Warming Drawer
Anti-Tip Block
Against Rear
• Wall Per
Warming
Drawer
Requirement
2" (5.1 era)
Min,
Per Warming
Drawer
Req=
1" (2.5 cm) Min. Above Toekick
When installing a Warming Drawer below
a single or double oven, a separate 120V,
60 Hz, properly grounded receptacle must
be installed. Refer to installation instructions
packed with the Warming Drawer for
specific installation requirements.
7
Cabinetry
Cutoutfor 27"(68.6o_)SingleOvensonly-
BelowanAdvantiumor ;rowave Oven
or BetweenanAdvantiumor crowave
OvenandaWarmingDrawer
For JKS10, JKP30, JKP70, PK91& ZEK938 models only.
Single 27" (68.6 cm) Oven
Below an Advantium or
Microwave Oven
Per Advantium or
Microwave Oven
Requirement
NOTE: The middle rail separating the two
openings may need to be larger than the 3"
(7.6 cm) minimum shown. Always refer to the
individual installation instructions packed with
each product for specific requirements.
Combined Advantium or Microwave
Oven and Wall Oven Installation:
When installed in combination with a
single wall oven, use separate electrical
junction boxes.
Refer to the Advantium or microwave
oven installation instructions for electrical
requirements of that product.
These connections must be made
by a qualified electrician. All electrical
connections must meet National Electrical
Code or prevailing local codes.
2" (5.1 cm) Min.
Note: Install the
oven only with
specific models
listed on the label
located on top of
the oven.
Single 27" (68.6 cm) Oven
Between an Advantium or
Microwave Oven and a
Warming Drawer
Per Advautium or
Microwave Oven
Requirement
Per Warming
Drawer
Req
NOTE: Additional clearances may be
required. Check to be sure the oven
supports above the Warming Drawer
do not obstruct the required interior depth
and height. The middle rail separating the
openings may need to be larger than the 2"
(5.1 cm) minimum shown. Always refer to
the individual installation instructions packed
with each product for specific requirements.
WarmingDrawerCombinedwith
Advantiumor MicrowaveOvenand
SingleOven:
Install a separate 120V, 60Hz, properly
grounded receptacle. See installation
instructions packed with each product
for specific requirements.
2" (5.1 cm) Min.
2" (5.1 cm) Min.
8
Installation instructions
Cutoutfor 30"(76.2c )Sing Built-in
Ovensonly
For JTP30, JTP70, PT916, PT920, ZET938 models only.
Allow 11/16"
(1.75 cm) for
overlap of oven
over side edges
of cutout
21 "
(53.3 cm)I'Y_'_ -
Allow a minimum
of 21" (53.3 cm) for
clearance to adjacent
corners, drawers,
walls, etc. when
door is open
Cutout
Width
28 1/2" (72.4 cm)
5/8"(72.7ore)
Max.
Opening
Between
inside Walls
Must Be
At Least
28 1/2"
(72.4 cm)
Wide
_AIl_w 1" (2.5 cm)
minimum for
overlap of oven
top and 1V4"
(3.2 cm) overlap
of oven bottom
of cutout
_--_ Cabinet
Width
30" (76,2 cm)
9 1/2" (24.1 cm)
I adjacent
I / cabinet)
(69.2 cm) Min,
27 5/16"
(69.4 cm) Ma
Recommended
cutout location
from floor 32 1/2"
(82,6 cm)
if the cabinet does not have a solid bottom,
two braces or runners must be installed
level with the bottom of the cutout to
support the weight of the oven. For single
ovens, the runners and braces must
support 150 Ibs (68 Kg).
NOTE: if marks, blemishes or the
cutout opening are visible above the
installed oven, it may be necessary to
add wood shims under the runners and
front trim until the marks or opening
are covered,
Junction Box
Location
(junction box
may be
located in
---t
22" (55.9 cm)
Min. to
Bottom of
Junction Box
---4
Suitable
Bracing
to Support
Runners --
Side by Side Installations
Install two wall ovens in separate cutouts.
Allow 2" (5.1 cm) min. between cutouts.
Cabinet Width
30" (76.2 cm)
Recommended
Cutout Location
from Floor
Cutout Depth
Cutout Width
32 1/2" (82.6 cm)
23 1/2" (59.7 cm) Min.
28 1/2" (72.4 cm) Min.
28 518" (72.7 cm) Max.
Cutout Height
27 1/4" (69.2 cm) Min.
27 5/16" (69.4 cm) Max.
Ill not have a front frame and the
t_1sides are less than 314" (1.9 cm)
-- 2"x4"
(5 cm x 10 cm
or equivalent
runners level
with bottom
of cutout
-_(s4 21s/8-
.9cm)over \
Centerline
of Cabinet
These ovens are not approved for
stackable installations.
Cutout- i 2"(5.1 cm)
Observe all Min.
dimensions I_ll'='=='==='='=i_
and I
requirements.J
9
Cutout -
Observe all
dimensions
and
requirements.
Installation instructions
Cutoutfor30"(76.2cm)
For JTP35, JTP55, JTP75, PT956, PT960, ZET958 models only.
Allow 11116"
(1.75 cm) for
overlap of oven .__
over side edges
of cutout
Allow a minimum
of 21" (53.3 cm) for
clearance to adjacent
corners_ d rawers_
walls, etc. when
door is open
\
21" (53.3 cm)_
Cutout
Width
28 1/2" (72.4 cm)
Min. -,_
28 5/8" (72.7 cm)
Max.
Between I
Inside Walls I
Must Be At
Least 28 1/2"
(72.4 cm) Wide
AHow 1" (2.5 cm)
minimum for
overlap of oven
top and 11/4"
(3 2 cm) over ap Max
of oven bottom - I
_t Location
Cutout
Height
51 13/16" 131.6 cm)
Min.
51 15/16" (131.9 cm)
9 1/2"
(24.1 cm) Junction Box
n cabinet)
ofcutout " F- _-I
(junction box
may be
located in
adjacent
/"
47" (119.4 cm)
Min.
to Bottom of
Junction Box
Ovensonly
Cabinet Width
Recommended
Cutout Location
from Floor
Cutout Depth
Cutout Width
Cutout Height
NOTE: If the cabinet does not
have a front frame and the sides
are less than 314" (1.9 cm) thick,
shim both sides equally to
establish the cutout width.
30" (76.2 cm)
12" (30.5 cm)
23 1/2" (59.7 cm) Min.
28 1/2" (72.4 cm) Min.
28 5/8" (72.7 cm) Max.
51 13/16" (131.6 cm) Min.
51 15116" (131.9 cm) Max.
--_ 30_ I cutout location
(76.2 cm)"_;,_from f!oor 12" (30.5 cm)
Cabinet _'_..L,_.
Width I
/1 Recommended
if the cabinet does not have a solid bottom,
two braces or runners must be installed
level with the bottom of the cutout to
support the weight of the oven. For
double ovens, the runners and braces
must support 275 Ibs (124 Kg).
NOTE: If marks, blemishes or the
cutout opening are visible above the
installed oven, it may be necessary to
add wood shims under the runners and
front trim until the marks or opening
are covered,
Suitable
Bracing --
to Support
Runners
-- 2"x4"
(Scm xtOcrn)
or equiva|eut
runners |eve|
with bottom
of cutout
10
Installation instructions
Cutoutfor 30"(76.2 Single lit-in
only Under Coun :r
For JTP30, JTPT0, PT916, PT920, ZET938 models only.
Gas or electric cooktops may be installed over this oven. See
cooktop installation instructions for cutout size. See label on
top of oven for approved cooktop models.
\
25" (63.5 cm)
Top and/or side fillers
may be necessary
if unit is positioned
between existing
cabinets. Be sure
they are attached
securely, since they
will anchor the oven
in the cabinet.
- 28 1/2" (72.4 cm) Min.
28 5/8" (72.7 cm) Max.
240V / 208V
Junction Box
Location (junction
box may be in
adjacent cabinet)
9 1/2"
(24.1 cm)
overlap top
Of oven_
-. 11/16" (1.8 cm)
_,"- overlap side edges
of cutout and
-- 1 114" (3.2 cm)
overlap bottom
Of oven,
(2.5 cm)
Ovens
Gas and electrical connections
for gas cooktop must be located
in an adjacent accessible
location to the right.
22" (55.9 cm) Min.
Above Support
Platform
36" (91.4 cm)
Typical
Countertop
Height
Side by Side Installations
Install two wall ovens in separate cutouts.
Allow 2" (5.1 cm) min. between cutouts.
NOTE: This oven is only
approved to be installed under
the specific models as labeled
on this unit.
Cutout - ] 2" (5.1 cm)
Observe all| Min.
dimensions_-,ql,,,,===,,,===,=,lm_"
and |
requirements.J
Observe all
dimensions
requirements.
Cutout -
and
24" (61 cm)
4" (10.2 cm)
Typical
Toekick
11
Cabinetry
Cutout for 30"(76.2c_)Single or
For JTP30, JTP35, JTP55, JTP70, JTP75, PT916, PT920, PT956, PT960,
ZET938, ZET958 models only.
Single 30" (76.2 cm)
Oven Over a Warming
Drawer
Per Warming
Drawer
Requirement
L_i-in Ovens only- Over a
_rrning Drawer
Double 30" (76.2 cm)
Oven Over a Warming
Drawer
Rear Wall Per Warming
Drawer Requirement
Block Against
2" (5J cm)
IVlin.
NOTE: Install the
oven only with
specific models
listed on the label
located on top of
the oven.
Per Warming
Drawer
Requirement
Double
Anti-Tip Block
Against Rear
Wall Per
Warming
Drawer
Requirement
2" (5.1 cm)
IVlin.
1" (2.5 cm) Min. Above Toekick or
Adjust to Oven Installation Height
NOTE: Additional clearances between cutouts
may be required. Check to be sure the oven
supports above the Warming Drawer location
do not obstruct the required interior depth and
height.
1" (2.5 cm) Min. Above Toekick
When installing a Warming Drawer below
a single or double oven, a separate 120V,
60 Hz, properly grounded receptacle must
be installed. Refer to installation instructions
packed with the Warming Drawer for
specific installation requirements.