GE JGS750DEF1BB, JGS750DEF1WW, JGS750DEF2BB, JGS750DEF2WW, JGS750DEF3BB Installation Guide

...
Installation Instructions Range
Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com
IN THE COMMONWEALTH OF MASSACHUSETTS
This product must be installed by a licensed
plumber or gas fitter.
WARNING
FIRE OR EXPLOSION HAZARD
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
Installation must be performed by a qualified installer.
Read these instructions completely and carefully. Installation of this range must conform with
local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/ NFPA.54, latest edition. In Canada, installation must conform with the current Natural Gas Installation Code, CAN/CGA-B149.1 or the current Propane Installation Code, CAN/CGA-B149.2, and with local codes where applicable. This range has been design-certified by CSA International according to ANSI Z21.1, latest edition and Canadian Gas Association according to CAN/ CGA-1.1 latest edition.
FOR YOUR SAFETY:
WARNING
• A child or adult can tip the range and be killed.
• Install the anti-tip bracket to the wall or floor.
• Engage the range to the anti-tip bracket by sliding the range back such that the foot is engaged.
• Re-engage the anti-tip bracket if the range is moved.
• Failure to do so can result in death or serious burns to children or adults.
If you did not receive an anti-tip bracket with your purchase, call 1.800.626.8774 to receive one at no cost. (In Canada, call 1.800.561.3344.) For installation instructions of the bracket, visit: www.GEAppliances.com. (In Canada, www.GEAppliances.ca.)
Tip-Over Hazard
When using ball type gas shut-off valves, they
shall be the T-handle type.
A flexible gas connector, when used, must not
exceed 3 feet.
When installing a gas appliance the use of old flexible connectors can cause gas leaks and personal injury. Always use a NEW flexible connector.
Leak testing of the appliance shall be conducted according to the manufacturer instructions.
The range must be electrically grounded in accordance with local codes or, in the absence of local codes, in accordance with the National Electrical Code (ANSI/NFPA 70, latest edition). In Canada, electrical grounding must be in accordance with the current CSA C22.1 Canadian Electrical Code Part 1 and/or local codes. See Electrical Connections in this section.
Do not install this product with an air curtain hood or other range hood that operates by blowing air down on the cooktop. This airflow may interfere with operation of the gas burners resulting in fire or explosion hazard.
Anti-Tip Bracket
Kit Included
WARNING
the installation, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Before beginning
TOOLS YOU WILL NEED MATERIALS YOU MAY NEED
Gas line shut-off valve
Phillips
screwdriver
Open-end or
Flat-blade
screwdriver
Pencil and ruler
Pipe wrenches (2)
(one for backup)
adjustable wrench
Level
Drill, awl or nail
BEFORE YOU BEGIN
,03257$17³
local inspector’s use.
Save these instructions for
,03257$17³ Observe all governing
codes and ordinances.
,03257$17³ Remove all packing
material and literature from oven before connecting gas and electrical supply to range.
,03257$17³ To avoid damage to your
cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).
Note to Installer – Be sure to leave these instructions with consumer.
Note to consumer – Keep these instructions for future reference.
Servicer – The electrical diagram is in an envelope attached to the back of the range.
Proper installation is the responsibility of the installer.
Pipe joint sealant or UL-approved pipe thread
tape with Teflon* that resists action of natural and LP gases
Flexible metal appliance connector (1/2 I.D.).
A 5-foot length is recommended for ease of installation but other lengths are acceptable. Never use an old connector when installing a new range.
Flare union adapter for connection to gas
supply line (3/4 or 1/2 NPT x 1/2 I.D.)
Flare union adapter for connection to pressure
regulator on range (1/2” NPT x 1/2” I.D.)
Liquid leak detector or soapy water. *Teflon: Registered trademark of DuPont
Product failure due to improper installation is not covered under warranty.
Before installing your range on linoleum or any other synthetic floor covering, make sure the floor covering can withstand 180°F without shrinking, warping or discoloring. Do not install the range over carpeting unless a sheet of 1/4” thick plywood or similar insulator is placed between the range and carpeting.
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Saftey, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/ NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the current standards CAN/CSA­A240-latest edition, or with local codes.
When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.
DIMENSIONS AND CLEARANCES
Provide adequate clearances between the range and adjacent combustible surfaces. These dimensions must be met for safe use of your range.
Allow 30” (76.2 cm) minimum clearance between burners and bottom of unprotected wood or metal cabinet, or allow a 24” (61 cm) minimum when bottom of wood or metal cabinet is protected by no less than 1/4” (6.4 mm) thick flame-retardant millboard covered with no less
than No. 28 MSG sheet metal (.015” [.38 mm] thick), .015” (.38 mm) thick stainless steel, .025” (0.64 mm) aluminum or .020” (0.5 mm) copper.
Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.
For island installation, maintain 2-1/2” minimum from cutout to back edge of countertop and 3” minimum from cutout to side edges of countertop.
31 1/4"
DIMENSIONS AND CLEARANCES (CONT.)
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
Recommended area for 120V outlet on rear wall and area for through-the-wall connection of pipe stub and shut-off valve.
Recommended area for through-the-floor connection of pipe stub and shut-off valve.
35” to 36-1/2”
from oor to countertop
24”
Max
18”
3 1/4"
Minimum to cabinets on either side of the range
6”
Minimum
clearance
to left wall
To cabinets below cooktop and at the range back
26 7/8"
w/o handle
29 3/8"
w/ handle
47 5/8"
30” Minimum
0”
30”
6” Minimum clearance to right wall
30"
Maximum
depth for
cabinets above
countertops
1/4”
13”
Front edge of the range side panel forward from cabinet
0” To cabinets below cooktop and at the range back
CONVERTING TO LP GAS (OR CONVERTING BACK TO NATURAL GAS FROM LP)
This range leaves the factory set for use with natural gas. If you want to convert to LP gas, the conversion must be performed by a qualified LP gas installer.
The conversion orifices and instructions can be found on back of the range.
Keep these instructions and all orifices in case you want to convert back to natural gas.
CAUTION To prevent drafts
from affecting burner operation, seal all openings in floor under appliance and behind appliance wall.
Rear of Range
Orifice Box (location may vary)
GAS SUPPLY
1
WARNING Fire Hazard: Do not use a
flame to check for gas leaks.
WARNING Explosion Hazard: Do not
exceed 25 ft-lbs of torque when making gas line connections. Overtightening may crack the pressure regulator resulting in fire or explosion hazard.
Gas Pressure Regulator
You must use the gas pressure regulator supplied with this range. For proper operations the inlet pressure to the regulator should be as follows:
Natural Gas:
Minimum pressure: 6” of Water Column Maximum pressure: 13” of Water Column
LP Gas:
Minimum pressure: 11” of Water Column Maximum pressure: 13” of Water Column
If you are not sure about the inlet pressure contact local gas supplier.
Shut off the main gas supply valve before disconnecting the old range and leave it off until the new hook-up has been completed. Don’t forget to relight the pilot on other gas appliances when you turn the gas back on.
Because hard piping restricts movement of the range, the use of a CSA International­certified flexible metal appliance connector is recommended unless local codes require a hard­piped connection.
If the hard piping method is used, you must carefully align the pipe; the range cannot be moved after the connection is made.
To prevent gas leaks, put pipe joint compound on, or wrap pipe thread tape with Teflon* around, all male (external) pipe threads.
A. Install a manual shut-off valve in the gas line
in an easily accessed location outside of the range. Make sure everyone operating the range knows where and how to shut off the gas supply to the range.
B. Install male 1/2” flare union adapter to the 1/2”
NPT internal thread at inlet of regulator. Use a backup wrench on the regulator fitting to avoid damage.
C. Install male 1/2” or 3/4” flare union adapter to
the NPT internal thread of the manual shut-off valve, taking care to back-up the shut-off valve to keep it from turning.
D. Connect flexible metal appliance connector
to the adapter on the range. Position range to permit connection at the shut-off valve.
E. When all connections have been made, make
sure all range controls are in the off position and turn on the main gas supply valve. Use a liquid leak detector at all joints and connections to check for leaks in the system.
When using pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the range and individual shut-off valve from the gas supply piping. When using pressures of 1/2 psig or less to pressure test the gas supply system, simply isolate the range from the gas supply system by closing the individual shut-off valve.
When checking for proper operation of the regulator, the inlet pressure must be at least 1” greater than the operating (manifold) pressure as given on rating label of product.
*Teflon: Registered trademark of DuPont
ELECTRICAL CONNECTIONS
2
WARNING Shock Hazard: This
appliance must be properly grounded. Failure to do so can result in electric shock.
Electrical Requirements - 120-volt, 60 Hertz,
properly grounded circuit protected by a 15-amp or 20-amp circuit breaker or time delay fuse. It is recommended that a separate circuit serving only this range be provided.
Note: Use of automatic, wireless, or wired external switches that shut off power to the appliance are not recommended for this product.
Grounding
The power cord of this appliance is equipped with a three-prong (grounding) plug which plugs into a standard three-prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance.
The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded.
SURFACE BURNERS
3
Cap
WARNING Fire or Explosion Hazard:
Do not operate the burner without all burner parts in place.
Make sure the notch in the
burner head is positioned
Burner
over the electrode.
Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD. DO NOT USE AN ADAPTER. DO NOT USE AN EXTENSION CORD.
Ground Fault Circuit Interrupters (GFCI’s) are not required or recommended for gas range receptacles. Performance of the range will not be affected if operated on a GFCI-protected circuit but occasional nuisance tripping of the GFCI breaker is possible.
Ensure proper ground exists before use
Cap
or
Notch Electrode
Hole
Electrode
CONNECTOR HOOKUP
Gas Flow into Range Gas Flow into Range
Pressure regulator
Adapter
Flexible
Option
1/2 or 3/4
Gas pipe
Installer: Inform the consumer of the location of the gas shut-off valve.
Flex connector (6 ft. max.)
Adapter
Gas shut-off valve
Elbow
Rigid Pipe
Option
Pressure regulator
Elbow
Nipple
Union
Nipple
Gas shut-off valve
1/2 or 3/4
Gas pipe
A. Burners - Place surface burners into
corresponding positions on cooktop. B. Caps - Place caps on proper size burner.. C. Continuous Grates - Place the left and
right grates on the cooktop. These grates
are marked “LEFT” and “RIGHT” on their
undersides. Place the center grate with its
short edge toward the front of the range.
Front right burner
Left RightCenter
Loading...
+ 5 hidden pages