GE JGP989TK, JGP989KK, JGP989BK Specification

GE JGP989TK, JGP989KK, JGP989BK Specification

JGP989TK/KK/BK

GE Profile30" Downdraft Gas Cooktop

Dimensions and Installation Information

Wall Installation: Wall installations require 25” countertop depth. When cabinet is flush against the wall, the fan housing can be rotated to the horizontal position for direct venting through rear wall. Make a countertop cutout in the range cabinet according to unit dimensions and installation type. Duct hole is positioned in back of cabinet for through-the-wall ducting. Requires special offset adapter JXRW89.

Peninsula or Island Installation: For peninsula/ islandsaminimum26”countertopdepthissuggested. Blower should be in vertical position. Island or peninsula cabinets may require adjustment in cutout depth and/or location within the width dimensions. Duct hole is positioned in bottom of cabinet for island or peninsula installation.

Slab Installation: For peninsula or island installation and rear wall ducting, 6” PVC duct or locally approved piping should be used if installing under a poured concrete slab.

Installation Information: Before installing, consult installation instructions, packed with product, for current dimensional data.

Note:Thesecooktopsareapprovedforindooruseonly.

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

21-7/8

22

3-1/4 x 10

20-1/2

20-5/8

29-7/8 2-1/4

28-3/4

 

 

 

9

 

 

 

 

C

4

 

 

28-7/8

L

25

 

16

 

 

 

10-1/2

 

 

 

 

 

1-7/8"

 

20

 

*U.L. Requirement.

MIN. Required*

 

 

 

 

 

 

 

 

 

*Note: A 5" minimum spacing to adjacent side wall is required Dimension and installation information are shown in inches.

Listed by

Underwriters

R Laboratories

Specification Created 11/04

230280

JGP989TK/KK/BK

GE Profile30" Downdraft Gas Cooktop

Dimensions and Installation Information

Installing the Ductwork: Use galvanized or aluminum duct in 6” round or 3-1/4” x 10” size, or combination of both. PVC duct or locally approved piping should be used if installing under a poured concrete slab.

Local building code must be followed in specifying type and schedule of all duct used.

Note: Ductwork must be vented to outside. Do not vent into a wall, ceiling, crawlspace, attic or any concealed space. Always use an appropriate roof or wall cap with damper.

Laundry-type wall caps should never be used. For maximum efficiency use the shortest and straightest duct run possible, with as few fittings as possible.

For satisfactory performance the duct run should not exceed 100 feet equivalent length. Refer to the table of equivalent lengths (shown in installation instructions) for various duct configurations.

Through Cabinet Toe Space

Between Floor Joist

Inside Wall to Roof

Direct to Outside

6-1/8

9-1/8

18-3/4

 

10-1/8

For answers to your Monogram,® GE Profileor

Downward Venting

Rear Wall Venting

GE® appliance questions, visit our website at

 

 

ge.com or call GE Answer Center® service,

 

Dimension and installation information are shown in inches.

800.626.2000.

 

Listed by

Underwriters

R Laboratories

Specification Created 11/04

230280