GE JVB67HBB, JP326, JP340, JP350, JP930 Installation Instructions Manual

...
6
If you have questions, call 800.GE.CARES or visit our Website at: www.GEAppliances.com
REMOVE PACKAGING
Open the carton and remove parts package. Check contents to be sure all pieces are present. (The parts package may be attached to the power cord.)
Remove the shipping materials. Remove the carton and set aside. The carton can be used as a pad when changing or adjusting vent direction.
Installation Downdraft Vent Instructions System
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT — Save these
instructions for local inspector’s use.
IMPORTANT — Observe all
governing codes and ordinances.
Note to Installer – Be sure to leave these instructions with the Consumer.
Note to Consumer – Keep these instructions for future reference.
Note – This appliance must be properly grounded.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Warranty.
TOOLS YOU WILL NEED
Flat-blade screwdriver
Jig saw
Ductwork to suit
the installation
Carpenter square
PARTS INCLUDED
Remote raise/lower assembly (for 36models only)
Stabilizing brackets
(all models) (4)
Wire box (2)
and screws (4)
Plastic strain
relief (2)
Wire and white
connector (1)
Switch cover
plate (1)
Attachment
bracket (1)
Pliers
Duct tape
7
Installation Instructions
DIMENSIONS AND CLEARANCES
CAUTION Wall coverings, countertops and
cabinets should withstand 200°F. heat generated by any cooktop.
A B
30Models 30 281⁄4 36Models 36 333⁄4
A
B
2
8
1
2
3
1
8
33⁄8
10
1
2
71⁄8
71⁄2
3
3
4
2
1
4
6
1
4
WARNING!
INSTALLATION SAFETY INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Installation work and electric wiring
must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Ducted fans must always be vented to
the outdoors.
When cutting or drilling into wall or
ceiling, do not damage electrical wiring and other hidden utilities.
WARNING — To reduce the risk of
fire, use only metal ductwork.
C
B
A
IMPORTANT: These vents are
recommended for island installations. Against-the-wall installations are limited due to countertop depth requirements. The vent and cooktop combined depth requires an extra deep flat countertop surface.
The countertop must be at least 26deep with a flat surface area of 23
1
2or more, front to back. (NOTE: JGP932S, JP350SC, JP930SC and JP938SC require 23
5
8flat surface area.) In addition, other clearances to the front edge of the countertop must be considered.
See specific cutout illustrations with your
cooktop model to determine requirements.
A countertop with
a raised lip or rolled front edge may not allow enough flat area for installation.
Flat surface area
24
27
Installation Instructions
8
ADVANCE PLANNING
DUCTWORK
Prepare ductwork to vent to the outdoors.
Use the shortest and straightest duct run
possible. The maximum permissible length for duct
run is 150 feet. Refer to Duct Fittings chart to calculate
equivalent length for various duct configurations.
The downdraft blower system is designed
to use 3
1
4x 10ductwork. It can be
transitioned to 6round.
Ductwork MUST be vented to the outside—
never into a crawl space, attic or other enclosed space.
Determine the need for a wall cap or roof
cap. Purchase the cap in advance from your home building center or plumbing supply.
CLEARANCES
Installation must conform with local codes.
The downdraft system with blower, motor
and duct work will occupy the cabinet below the countertop and cooktop.
The blower/motor assembly can be located below the cabinet floor. The assembly will fit between 16floor joists.
In this installation a transition to 6 round is required.
The blower motor assembly can also be installed outdoors. Order JXBC67 for remote blower installations outdoors.
Refer to Dimensions and Clearances for information on appropriate placement and necessary clearances when planning installation.
Refer to your specific cooktop installation instruction for other appropriate clearances.
Avoid placing cabinetry directly above the cooking surface when possible.
If cabinetry is used above the cooking surface:
Installation must conform with local codes. Use cabinets no more than 13deep. Maintain 30minimum clearance between
cooktop and unprotected cabinets directly above cooktop.
If clearance is less than 30″, protect cabinet bottoms with flame-retardant millboard at least 1/4thick or gypsum board at least 3/16thick covered with 28 gauge sheet steel or .02thick copper.
Clearance between cooktop and protected cabinetry must not be less than 24″.
EXCEPTION: Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.
Working areas adjacent to the cooktop should maintain 18minimum clearance between countertop and cabinet bottom.
COOKTOP ELECTRICAL AND GAS LOCATION
Plan the placement of the electrical outlet and gas (if used) carefully. Gas or electrical outlets cannot be placed on the back wall of the cabinet because it may interfere with the downdraft plenum.
Install a standard electrical outlet within reach of the vents’ 2 foot long power cord.
The vent and a gas cooktop combination can operate from the same 120V standard duplex outlet.
Electric cooktops must operate from a separate 240V junction box.
REMOTE SWITCH
(for 36models only)
The downdraft vent has a separate raise/lower switch. Plan to install the switch in a convenient location outside of the vent/cooktop cutout.
9
Installation Instructions
Base
cabinet
INSTALLATION POSSIBILITIES
When the kitchen design calls for an against the wall installation, move 24deep base cabinet forward, 3to 5″. Filler panels can be angled or flat to fill the space between adjacent cabinets.
Maintain cutout clearances to front edge as specified.
In an island or peninsula, the countertop can be extra deep to provide seating opposite of the cooktop. Adding base cabinets on each side of the cooktop provides extra storage and countertop work space.
Filler
panel
Filler
panel
Base sink 30Min. for JVB37 36Min. for JVB67
18
Base to sink
30to 42
Cover
panel
Countertop overhang per cooktop clearances must be maintained
End
panel
18