GE JGP633, PGP966 Installation Instructions

Installation
36s Sealed Gas Cooktop
JGP633, JGP970, PGP966, ZGU36
Instructions
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com In Canada, call 1.800.561.3344 or Visit our Website at: www.geappliances.ca
IN THE COMMONWEALTH OF MASSACHUSETTS:
• This product must be installed by a licensed plumber or gas fitter.
• When using ball-type gas shut-off valves, they shall be the T-handle type.
• A flexible gas connector, when used, must not exceed 3 feet.
Read these instructions completely and carefully.
IMPORTANT ³ Save these instructions
for local inspector’s use.
IMPORTANT ³Observe all governing
codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions for
future reference.
• Product failure due to improper installation is not
covered under the Warranty.
WARNING
properly grounded.
IMPORTANT ³ Leak testing of the
appliance shall be conducted according to the manufacturer’s instructions.
• Proper installation is the responsibility of the
installer and product failure due to improper installation is NOT covered under warranty.
WARNING
at the main circuit breaker or fuse box before installing.
This appliance must be
Disconnect all electrical power
FOR YOUR SAFETY:
WARNING
instructions is not followed exactly, a fire, explosion or gas leak may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance!
Do not install this product with an air curtain hood or other range hood that operates by blowing air down on the cooktop. This airflow may interfere with operation of the gas burners resulting in fire or explosion hazard.
If the information in these
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
This cooktop has been design certified by CSA International. You’ll find safety precautions in your Owner’s Manual. Read them carefully.
• Installation of this cooktop must conform with local codes or, in the absence of local codes with the National Fuel Gas Code,
• Be sure your cooktop is installed properly by a qualified installer or service technician.
• To eliminate reaching over surface burners, cabinet storage above burner should be avoided.
• Do not install the unit near an outside door or where a draft may affect its use.
31-10861-2 (05-17 GEA)
1
Installation Instructions
IMPORTANT SAFETY INSTRUCTIONS
ELECTRICAL REQUIREMENTS
This appliance must be supplied with the proper voltage and frequency and connected to an individual, properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as noted on the rating plate.
We recommend you have the electrical wiring and hookup of your cooktop connected by a qualified electrician. After installation, have the electrician show you where your main cooktop disconnect is located.
Check with your local utilities for electrical codes which apply in your area. Failure to wire your cooktop according to governing codes could result in a hazardous condition. If there are no codes, your cooktop must be wired and fused to meet the requirements of the National
(OHFWULFDO&RGH$16,1)3$1R³/DWHVWHGLWLRQ
You can get a copy by writing:
National Fire Protection Association
Batterymarch Park Quincy, MA 02269
PARTS INCLUDED
2 Screws
Foam Tape
(Glass Top
Models Only)
MATERIALS YOU MAY NEED
Joint Sealant
CSA-Approved Flexible Gas Line
3/8s Min. ID, 1/2s NPT Connection,
3-foot Maximum Length (Massachusetts Only)
Pipe Fittings
2 Hold
Down Brackets
Shut-Off Valve
In Canada your cooktop must be wired and fused to meet the requirements of the Canadian Electrical Code, CSA C22.1-02.
Be sure the installation of this product in a mobile home conforms with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280. If this standard does not apply, you must follow the standard for Manufactured Home Installations, ANSI A225.1 and Manufactured Home Installations, Sites and Communities and ANSI/NFPA 501A or with local codes. You can get a copy of the Federal Standard by Writing:
Office of Mobile Home Standards
HUD Building
451 7th Street, S.W.
Washington, D.C. 24010
TOOLS YOU WILL NEED FOR INSTALLATION
Pencil
Saber Saw
Phillips-Head
Screwdriver
Pipe Wrench
Ruler or Straightedge
1/8s Drill Bit & Electric or
Hand Drill
Safety Glasses
2
Installation Instructions
PRE-INSTALLATION CHECKLIST
When preparing cooktop opening, make
A
sure the inside of the cabinet and the cooktop do not interfere with each other. (See section on preparing the opening.)
Remove packaging materials, grate boxes,
B
regulator with literature, and literature package from the cooktop before beginning installation.
Literature Package
Foam Packaging
Cooktop
Grate boxes
Remove Installation Instructions from
C
literature pack and read them carefully before you begin.
Be sure to place all literature, Use and Care,
Installations, etc. in a safe place for future reference.
Make sure you have all the tools and
D
materials you need before starting the installation of the cooktop.
Your home must provide the adequate
E
electrical service needed to safely and properly use your cooktop. (Refer to section on electrical requirements.)
When installing your cooktop in your home,
F
make sure all local codes and ordinances are followed exactly as stated.
Make sure the wall coverings, countertop
G
and cabinets around the cooktop can withstand heat (up to 200°F) generated by the cooktop.
3
Installation Instructions
PREPARING THE OPENING
MAINTAIN THE FOLLOWING
1
MINIMUM CLEARANCE DIMENSIONS
13s MAX. Depth of unprotected overhead cabinets
30s MIN. clearance from countertop to unprotected overhead surface
3-3/4s MIN. clearance from cutout to side wall on the left of the unit
6s MIN. clearance from
3 3/4 MIN.
cutout to side wall on the right of the unit
18s MIN. height from countertop to nearest cabinet on either side of unit
7/16s
RECOMMENDED GAS SUPPLY
4
LOCATION FROM BACKWALL
1” Min. From Backwall
Recommended gas supply location
From Cutout
Center Line
NOTE: Allow 7/16” minimum vertical clearance from the
3-5/8s
DRAWER
cooktop bottom (or 3-5/8” minimum depth from the countertop) to any combustible surfaces, such as a cabinet drawer.
For island installation, maintain 2-1/2 in. minimum from cutout to front and back edge of countertop. Maintain 3 in. minimum from cutout to side edges of countertop.
OVERALL COOKTOP DIMENSIONS
2
21s(21-1/4s Max. for
36s
Cooktop
18-7/8s
Glass Top models)
33-11/16s
3-3/16s
(3-1/16” on Model ZGU36)
MAKE SURE WALL COVERINGS,
5
COUNTERTOP AND CABINETS AROUND COOKTOP CAN WITHSTAND HEAT (UP TO 200°F) GENERATED BY COOKTOP
Wall covering, cabinets and countertop must withstand heat up to 200°F
FOR AMERICANS WITH DISABILITIES
6
ACT (ADA) FORWARD APPROACH INSTALLATION ONLY:
5”
CUTOUT DIMENSIONS OF
3
COUNTERTOP
To ensure accuracy, it is best to make a template
when cutting the opening in the counter.
19-1/8” width cut
2-1/4” Min. Between
cutout and the wall behind the cooktop
2-1/2” Min. from
front edge of cutout
and front edge of
33-7/8”
length
of cut
countertop
16-15/16s
Allow 5” minimum depth between the countertop and an enclosure.
NOTE: The enclosure must be made of wood material. Also, an access panel is required for the electrical outlet , pressure regulator, shut-off valve, hold-down brackets, and service.
4
Installation Instructions
INSTALLING THE COOKTOP UNIT
LOCATE ELECTRICAL OUTLET AND
1
GAS SHUT-OFF VALVE BENEATH CABINET
NEVER REUSE OLD CONNECTORS WHEN INSTALLING THIS UNIT.
Install a manual shut-off valve in the gas line in an easily accessible location outside the cooktop. Be sure you know how and where to shut off the gas supply to the cooktop. Install the electrical outlet 12s below the countertop.
PROTECT SURFACE OF COOKTOP
2
Place a towel or tablecloth onto the countertop. Lay the cooktop upside down onto the protected surface.
Shut-Off
Valve
Electrical
Outlet 12s
Below
Countertop
LOCATE MOUNTING PARTS
4
Remove the hold-down brackets from the literature package.
ATTACH BRACKETS TO COOKTOP
5
Remove the screw from the bottom of the cooktop and screw the hold-down bracket to the side of the cooktop unit. Repeat for opposite side of cooktop.
Pre-drilled
Bottom
of Cooktop
Cooktop
Glass
hole
Foam Tapes
Bottom of cooktop
Cloth under Cooktop
ATTACH FOAM TAPE
3
(glass maintop models only)
Apply the foam tape around the outer edge of the glass. Do not overlap the foam tapes.
Bottom of Cooktop
Cooktop Glass
Foam Tapes
INSERT COOKTOP INTO CUTOUT
6
Insert the cooktop centered into the cutout opening. Make sure the front edge of the countertop is parallel to the cooktop. Make final check that all required clearances are met.
Cooktop
Once the unit is in place, screw the hold-down bracket into the cabinet sides to secure the unit into place.
5
Installation Instructions
INSTALL$7,21³*$6&211(&7,216
PROVIDE ADEQUATE
1
GAS SUPPLY
This cooktop is designed to operate on natural gas at 4s of water column manifold pressure and 7s of water column (W.C.) supply pressure. It is shipped from the factory set for natural gas. The convertible pressure regulator supplied with the unit must be connected in series with the manifold of the cooktop and must remain in series with the supply line regardless of whether natural or L.P. gas is being used. FOR PROPER OPERATION, THE MAXIMUM INLET PRESSURE TO THE REGULATOR MUST BE NO MORE THAN 14s OF WATER COLUMN PRESSURE. For checking the regulator, the inlet pressure must be at least 1s W.C.. (or 3.4 KPA) greater than the regulator output setting. If the regulator is set for 4s W.C. of water column pressure, the inlet pressure must be at least 5sW.C. If the regulator is set for 10sW.C., the inlet pressure must be at least 11s W.C.. The gas supply line to the cooktop should be 1/2s or 3/4s pipe.
INSTALL REGULATOR
2
NEVER REUSE OLD CONNECTORS WHEN INSTALLING THIS COOKTOP.
WARNING
flexible connectors. The use of old flexible connectors can cause gas leaks and personal injury. Always use new flexible connectors when installing a gas appliance.
Screw a section of pipe onto the inlet end of the pressure regulator and install the coupling.
Never reuse old
Pressure
Regulator
Coupling
INSTALL REGULATOR ONTO
3
BURNER BOX BOTTOM
Screw the regulator onto the burner box bottom pipe connection. Make sure the top of the regulator is facing towards the cabinet front, easily accessible through the cabinet doors.
COMPLETE CONNECTION WITH A
4
Pressure
Regulator
Coupling
Shut-Off
Valve
COUPLING
Complete the connection between the regulator, pipe coupling, and the shut-off valve.
Pressure
Regulator
Coupling
Shut-Off
Valve
Electrical
Outlet 12s
Below
Countertop
Electrical
Outlet 12s
Below
Countertop
To reduce the likelihood of gas leaks, apply teflon tape or a thread compound approved for use with Propane (LP) or Natural gases to all threaded connections.
6
Installation Instructions
CHECK FOR LEAKS
5
Before testing for leaks, make sure all burner knobs are in the OFF position.
After connecting the cooktop to gas, check system for leaks with a manometer. If a manometer is not available, turn the gas supply on to the cooktop and use a liquid leak detector at all joints and connections to check for leaks.
Tighten all connections if necessary to prevent gas leakage in the cooktop or supply line.
DO NOT USE OPEN FLAME TO CHECK FOR LEAKS!
Disconnect the cooktop and its individual shut-off valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psig (3.5 kPa).
Isolate the cooktop from the gas supply piping system by closing its individual shut-off valve during any pressure testing of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).
INSTALLATION OVER
6
BUILT-IN OVEN
See built-in oven installation for complete installation instructions.
5s To Center of
2s Dia. Hole From
Countertop
90° Elbow
2s Dia. Hole
(20 7/8s from front
of Countertop to
Cabinet Sides
Hole Center)
7
Installation Instructions
,167$//$7,21³(/(&75,&$/&211(&7,216
ELECTRICAL SUPPLY AND OUTLET
2
WARNING
at the main circuit breaker or fuse box before installing.
EXTENSION CORDS
1
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it be a UL listed 3-wire grounding type appliance extension cord and that the current carrying rating of the cord in amperes be equivalent to or greater than the branch circuit rating. Such extension cords are obtainable through your local appliance dealer.
Disconnect all electrical power
IMPORTANT: (Please read carefully) FOR
PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
An adequate electrical supply and outlet must be used to operate the electrical parts of your cooktop.
The power cord of this appliance is equipped
A
with a 3-prong (grounding) plug which must be used with a properly grounded 3-hole outlet with a standard 120 Volt, 60 cycle AC household current.
B
If you do not have a 3-hole grounded outlet,
have a qualified electrician change your old one.
A grounding adaptor will be needed to convert
C
the old one until the outlet can be replaced. This method is only temporary, and a qualified electrician should test it to be sure it meets requirements.
N
Ensure proper
ground and
L
firm connection
before use
TWO-PRONG WALL RECEPTACLE
3
Where a standard 2-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded 3-prong wall receptacle.
Do not under any circumstances cut or remove grounding prong from the cooktop cord. Failure to provide proper polarization may create a hazardous condition.
8
Installation Instructions
USAGE SITUATIONS WHERE
4
APPLIANCE POWER CORD WILL BE DISCONNECTED INFREQUENTLY
For 15 amp circuit only. Do not use an adaptor on a 20 amp circuit. Where local codes permit, a TEMPORARY CONNECTION may be made to a properly grounded two-prong wall receptacle by the use of a UL-listed adaptor available at most hardware stores. The larger slot in the adaptor must be aligned with the large slot in the wall receptacle to provide proper polarity in the connection of the power cord.
Ensure proper ground and firm connection before use
Align large
prongs/slots
(Adaptor plugs not permitted in Canada)
Temporary Method
CAUTION
terminal to the wall receptacle cover screw does not ground the appliance unless the screw is metal, and not insulated, and the wall receptacle is grounded through the house wiring. The customer should have the circuit checked by a qualified electrician to make sure the receptacle is properly grounded.
When disconnecting the power cord from the adaptor, always hold the adaptor with one hand. If this is not done, the adaptor ground terminal is very likely to break with repeated use. Should this happen, DO NOT USE the appliance until a proper ground has again been established.
Usage situation where appliance power cord will be disconnected frequently.
Do not use an adaptor plug in these situations because disconnection of the power cord places undue strain on the adaptor and leads to eventual failure of the adaptor ground terminal. The customer should have the 2-prong receptacle replaced with a 3-prong (grounding) receptacle by a qualified electrician before using the appliance.
Attaching the adaptor ground
9
Installation Instructions
COOKTOP BURNERS
ASSEMBLING THE COOKTOP
1
BURNERS
The electrode of the spark igniter is exposed. Be careful not to push any cooktop controls while the top of the burner is removed. Do not remove the top or touch the electrode of any burner while another burner is turned on. Electrical shock might result.
Replace the burner head onto the burner
A
base, making sure that the head is properly oriented over the burner base and the electrode. Make sure to place the correct burner head on the correct burner base and that the burner head sits level on the burner base. The burner heads are not interchangeable.
Place the burner
B
caps on the burner heads, making sure to place the correct burner cap on the correct burner head. The burner caps are not interchangeable. Make sure that the burner caps are properly seated on the burner heads.
Burner cap properly seated
Burner cap not properly seated
Make sure the pins in
C
the burner heads match the burner base indentations and that they are properly seated in them by rotating the heads until they are level.
Make sure the slot in
the burner head is positioned over the electrode. The burner cap has three to four pins. When replacing the
Stability
chamber
cap, make sure none of the pins sits in the stability chamber.
Make sure the hole
in the burner head assembly is positioned over the electrode and that the burner head is fully inserted inside the burner base. A small gap between the base and head is normal.
Burner head
Locator pins
Pin indentations
Burner cap
Burner head
Burner base
Burner head
assembly
Burner cap
Electrode
Burner
base
Electrode
Burner cap
10
Electrode
Burner
base
Loading...
+ 22 hidden pages