IN THE COMMONWEALTH OF

When using ball type gas shut-off valves, they

MASSACHUSETTS

shall be the T-handle type.

A flexible gas connector, when used, must not

This product must be installed by a licensed

exceed 3 feet.

plumber or gas fitter.

 

 

 

WARNING

FIRE OR EXPLOSION HAZARD

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

Installation must be performed by a qualified installer.

Read these instructions completely and carefully.

Installation of this range must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/ NFPA.54, latest edition. In Canada, installation must conform with the current Natural Gas Installation Code, CAN/CGA-B149.1 or the current Propane Installation Code, CAN/CGA-B149.2, and with local codes where applicable. This range has been design-certified by CSA International according to ANSI Z21.1, latest edition and Canadian Gas Association according to CAN/ CGA-1.1 latest edition.

When installing a gas appliance the use of old flexible connectors can cause gas leaks and personal injury. Always use a NEW flexible connector.

Leak testing of the appliance shall be conducted according to the manufacturer instructions.

The range must be electrically grounded in accordance with local codes or, in the absence of local codes, in accordance with the National Electrical Code (ANSI/NFPA 70, latest edition). In Canada, electrical grounding must be in

accordance with the current CSA C22.1 Canadian Electrical Code Part 1 and/or local codes. See Electrical Connections in this section.

Do not install this product with an air curtain hood or other range hood that operates by blowing air down on the cooktop. This airflow may interfere with operation of the gas burners resulting in fire or explosion hazard.

FOR YOUR SAFETY:

WARNING

Tip-Over Hazard

A child or adult can tip the range and be killed.

Install the anti-tip bracket to the wall or floor.

Engage the range to the anti-tip bracket by sliding the range back such that the foot is engaged.

Re-engage the anti-tip bracket if the range is moved.

Failure to do so can result in death or serious burns to children or adults.

If you did not receive an anti-tip bracket with your purchase, call 1.800.626.8774 to receive one at no cost. (In Canada, call 1.800.561.3344.) For installation

instructions of the bracket, visit: www.GEAppliances.com. (In Canada, www.GEAppliances.ca.)

Anti-Tip Bracket

Kit Included

WARNING Before beginning

the installation, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

TOOLS YOU WILL NEED

Phillips screwdriver

 

Open-end or

Flat-blade

adjustable wrench

 

screwdriver

 

Pencil and ruler

Level

 

Pipe wrenches (2)

Drill, awl or nail

(one for backup)

 

MATERIALS YOU MAY NEED

Gas line shut-off valve

Pipe joint sealant or UL-approved pipe thread tape with Teflon* that resists action of natural and LP gases

Flexible metal appliance connector (1/2” I.D.). A 5-foot length is recommended for ease of installation but other lengths are acceptable. Never use an old connector when installing a new range.

Flare union adapter for connection to gas supply line (3/4” or 1/2” NPT x 1/2” I.D.)

Flare union adapter for connection to pressure regulator on range (1/2” NPT x 1/2” I.D.)

Liquid leak detector or soapy water.

*Teflon: Registered trademark of DuPont

BEFORE YOU BEGIN

,03257$17 ³Save these instructions for local inspector’s use.

,03257$17 ³ Observe all governing codes and ordinances.

,03257$17 ³ Remove all packing material and literature from oven before connecting gas and electrical supply to range.

,03257$17 ³ To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).

Note to Installer – Be sure to leave these instructions with consumer.

Note to consumer – Keep these instructions for future reference.

Servicer – The electrical diagram is in an envelope attached to the back of the range.

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under warranty.

Before installing your range on linoleum or any other synthetic floor covering, make sure the floor covering can withstand 180°F without shrinking, warping or discoloring. Do not install the range over carpeting unless a sheet of 1/4” thick plywood or similar insulator is placed between the range and carpeting.

Mobile Home - Additional Installation Requirements

The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Saftey, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/ NFPA 501A or with local codes.

In Canada, the installation of this range must conform with the current standards CAN/CSA- A240-latest edition, or with local codes.

When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.

GE JGB635DEK2BB, JGB635DEK2CC, JGB635DEK2WW, JGB635REK2SS, JGBS60DEK2BB Installation Guide

DIMENSIONS AND CLEARANCES

Provide adequate clearances between the range and adjacent combustible surfaces. These dimensions must be met for safe use of your range.

Allow 30” (76.2 cm) minimum clearance between burners and bottom of unprotected wood or metal cabinet, or allow a 24” (61 cm) minimum when bottom of wood or metal cabinet is protected by no less than 1/4” (6.4 mm) thick flame-retardant millboard covered with no less

than No. 28 MSG sheet metal (.015” [.38 mm] thick), .015” (.38 mm) thick stainless steel, .025” (0.64 mm) aluminum or .020” (0.5 mm) copper.

Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.

For island installation, maintain 2-1/2” minimum from cutout to back edge of countertop and

3” minimum from cutout to side edges of countertop.

10 1/4"

36 1/4" ± 1/4

26 1/4"

w/o handle

28 3/4"

w/ handle

46 1/4"

 

 

Minimum to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cabinets on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

either side

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of the range

 

 

 

 

 

 

30”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2”

 

 

 

 

 

 

 

 

30”

 

 

 

2”

18”

Minimum

 

 

 

 

 

Minimum

 

Minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

clearance

 

 

 

 

 

 

 

 

 

 

 

 

clearance to

 

 

to left wall

 

 

 

 

 

 

 

 

 

 

 

 

right wall

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To cabinets

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

below cooktop

 

 

 

 

 

0”

 

 

 

 

 

 

and at the

 

 

 

 

 

 

 

 

 

 

 

 

 

range back

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30"

 

Maximum

 

 

 

 

depth for

 

 

 

cabinets above

 

 

 

 

countertops

 

 

 

 

 

 

 

 

 

 

15”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front edge

 

 

 

 

 

 

of the range

 

 

 

 

 

 

 

 

 

 

 

 

side panel

 

 

 

 

 

 

forward from

 

 

 

1/4”

 

 

cabinet

 

 

0”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To cabinets

 

 

 

 

 

 

 

 

 

 

 

 

 

below cooktop

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and at the

 

 

 

 

 

 

 

 

 

 

 

 

 

range back

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS AND CLEARANCES (CONT.)

GAS PIPE AND ELECTRICAL OUTLET LOCATIONS

Recommended area for 120V outlet on rear wall and area for through-the-wall connection of pipe stub and shut-off valve.

Recommended area for through-the-floor connection of pipe stub and shut-off valve.

CAUTION To prevent drafts from affecting burner operation, seal all openings in floor under appliance and behind appliance wall.

CONVERTING TO LP GAS

Rear of Range

(OR CONVERTING BACK TO

 

NATURAL GAS FROM LP)

 

This range leaves the factory set for use with natural gas. If you want to convert to LP gas, the conversion must be performed by a qualified LP gas installer.

The conversion orifices and instructions can be found on back of the range.

Keep these instructions and all orifices in case you want to convert back to natural gas.

Orifice Box

Orifice Strip

(location

(location

may vary)

may vary)

1 GAS SUPPLY

WARNING Fire Hazard: Do not use a flame to check for gas leaks.

WARNING Explosion Hazard: Do not exceed 25 ft-lbs of torque when making gas line connections. Overtightening may crack the pressure regulator resulting in fire or explosion hazard.

Gas Pressure Regulator

You must use the gas pressure regulator supplied with this range. For proper operations the inlet pressure to the regulator should be as follows:

Natural Gas:

Minimum pressure: 6” of Water Column Maximum pressure: 13” of Water Column

LP Gas:

Minimum pressure: 11” of Water Column Maximum pressure: 13” of Water Column

If you are not sure about the inlet pressure contact local gas supplier.

Shut off the main gas supply valve before disconnecting the old range and leave it off until the new hook-up has been completed. Don’t forget to relight the pilot on other gas appliances when you turn the gas back on.

Because hard piping restricts movement of the range, the use of a CSA Internationalcertified flexible metal appliance connector is

recommended unless local codes require a hardpiped connection.

If the hard piping method is used, you must carefully align the pipe; the range cannot be moved after the connection is made.

To prevent gas leaks, put pipe joint compound on, or wrap pipe thread tape with Teflon* around, all male (external) pipe threads.

A.Install a manual shut-off valve in the gas line in an easily accessed location outside of the range. Make sure everyone operating the range knows where and how to shut off the gas supply to the range.

B.Install male 1/2” flare union adapter to the 1/2” NPT internal thread at inlet of regulator. Use a backup wrench on the regulator fitting to avoid damage.

C.Install male 1/2” or 3/4” flare union adapter to the NPT internal thread of the manual shut-off valve, taking care to back-up the shut-off valve to keep it from turning.

D.Connect flexible metal appliance connector to the adapter on the range. Position range to permit connection at the shut-off valve.

E.When all connections have been made, make sure all range controls are in the off position and turn on the main gas supply valve.

Use a liquid leak detector at all joints and connections to check for leaks in the system.

When using pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the range and individual

shut-off valve from the gas supply piping. When using pressures of 1/2 psig or less to pressure test the gas supply system, simply isolate the range from the gas supply system by closing the individual shut-off valve.

When checking for proper operation of the regulator, the inlet pressure must be at least 1” greater than the operating (manifold) pressure as given on rating label of product.

*Teflon: Registered trademark of DuPont

CONNECTOR HOOKUP

Gas Flow into Range

Pressure regulator

Adapter

Flex

connector

 

 

(6 ft. max.)

Adapter

Flexible

 

 

 

 

Gas

Option

1/2” or 3/4”

 

 

 

shut-off

 

 

 

 

Gas pipe

 

 

 

valve

 

 

 

 

 

Gas Flow into Range

Elbow

Elbow

 

Nipple

Pressure

Union

regulator

 

 

Nipple

 

Gas

Rigid Pipe

shut-off

valve

Option

1/2” or 3/4”

 

 

Gas pipe

Installer: Inform the consumer of the location of the gas shut-off valve.

2 ELECTRICAL CONNECTIONS

WARNING Shock Hazard: This appliance must be properly grounded. Failure to do so can result in electric shock.

Electrical Requirements - 120-volt, 60 Hertz, properly grounded circuit protected by a 15-amp or 20-amp circuit breaker or time delay fuse. It is recommended that a separate circuit serving only this range be provided.

Note: Use of automatic, wireless, or wired external switches that shut off power to the appliance are not recommended for this product.

Grounding

The power cord of this appliance is equipped with a three-prong (grounding) plug which plugs into a standard three-prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance.

The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded.

Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle.

DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD. DO NOT USE AN ADAPTER. DO NOT USE AN EXTENSION CORD.

Ground Fault Circuit Interrupters (GFCI’s) are not required or recommended for gas range

receptacles. Performance of the range will not be affected if operated on a GFCI-protected circuit but occasional nuisance tripping of the GFCI breaker is possible.

Ensure proper ground exists before use

3

SURFACE BURNERS

Cap

 

 

WARNING Fire or Explosion Hazard:

Do not operate the burner without all burner

parts in place.

A.Burners - Place surface burners into corresponding positions on cooktop.

B.Caps - Place caps on proper size burner..

C.Single Grates - Place the oval (center) head/ cap assembly over the electrode on the cooktop.

Burner

 

Make sure the notch in the

Notch

burner head is positioned

 

over the electrode.

Electrode

Locator Bumps

Loading...