GE HLUF, VLUF Data Sheet

GE
Lighting Solutions
Flood Lighting
Powerflood™ (HLUF & VLUF)
imagination at work
Product Features
GE floodlights bring the security and safety of high quality illumination to a variety of outdoor areas. With a great look, performance and durability, these fixtures offer versatility while meeting your outdoor lighting requirements.
Applications
• Parking lots, industrial yards, construction sites, recreational areas, facade lighting, and other outdoor area applications
• Particularly suited for high corrosion atmosphere, sea coast and marine applications
Housing
• Heavy-duty corrosion-resistant fiberglass reinforced polyester housing
• Enclosed, gasketed and activated-charcoal filtered optical assembly
Ratings
Listed Suitable for Wet Locations
/
Reflectors
• Hydroformed aluminum reflector with ALGLAS™ finish
Unique Features
• Heavy-gauge steel trunnion
• Corrosion-resistant hardware
• Built-in aiming sight
• Removable ballast tray
• Mogul base socket – E39 standard
• Heat and shock resistant tempered glass lens
Ordering Number Logic
Powerflood™ (HLUF & VLUF)
X DB _ _ _ _ - _ _ - _ - _ - _ - _ - _ _ _ - _ _ - _
VLUF
optional slipfitter)
HLUF
(Shown with
PROD. ID
HLUF =
Horizontal Powerflood Floodlight (HPS only)
VLUF = Vertical Powerflood Floodlight
WATTAGE
20 = 200 24 = 250/
400 25 = 250 40 = 400* NOTE: 250/400 connected for 250W
*NOTE:
400W HPS Aiming Restriction Horizontal ±60°.
LIGHT
SOURCE
E = Energy Act
Compliant Pulse MH (EPMH)
S = HPS M = MH
Standard: Lamp not included.
VOLTAGE
60Hz 0 = 120/208/
240/277 Multivolt
1 = 120 2 = 208 3 = 240 4 = 277 5 = 480 D = 347 F = 120X347* T = 220
50Hz 6 = 220
*Connected for 120V
BALLAST
TYPE
See Ballast and Photometric Selection Table
A = Autoreg
(Standard)
G = Mag-Reg
with Grounded Socket Shell
M = Mag-Reg
(HPS only)
P = CWI with
Grounded Socket Shell
PE
FUNCTION
1 = None 2 = PE
Receptacle
4 = PE
Receptacle and Shorting Cap
NOTE:
Receptacle connected same voltage as unit. Order PE Control separately.
NEMA TYPE BEAM
SPREAD
HORIZ X VERT
Select NEMA Type from Ballast and Photometric Selection Table
Example: 4X2 = 4X2
DB = Dark Bronze
Ballast and Photometric Selection Table
All light sources are clear unless otherwise indicated.
NEMA Type metric 120, 208 Beam Spread Curve Light 240, 277 347, Horiz X Vert Number Wattage Source Multivolt 480 120 X 347 220 220 (Degrees) 35-
HLUF
200, 250, 400 HPS A, G, M** A, G, M** A, G, M** A A 4X2 (69X25) 176592 200, 250, 400 HPS A, G, M** A, G, M** A*, G, M** A A 6X5 (114X92) 176591
VLUF
200, 250, 400 HPS A, M** A, M** A*, G, M** A A 7X6 (154X126) 176588 250, 320 EPMH A A A A A 7X6 176593 350, 400 EPMH A A A, P A A 7X6 (151X102) 176589
CANADA & EXPORT ONLY
250 MH N/A N/A A A A 7X6 (151X102) 176589 400 MH N/A N/A A*, P A A 7X6 (151X102) 176589
NOTES: *200, 250/400 dual wattage HPS not available in 347 volt. **250/400 dual wattage fixture requires autoreg ballast
Ballast Type/Voltage 60Hz 50Hz Photo-
OPTIONSCOLOR
B = Time Delay
Automatically Switched Quartz
F = Fusing (Not
available with multivolt)
G = Top Trunnion K = Knuckle Slipfitter
for 1.9-in. to 2.38-in. (48-60 mm) OD Tenon
P = Prewired with 6 ft
(2 meters) #14/3
S = Knuckle Slipfitter
for 1.9 to 3.0 in. (48-76mm) OD Tenon
V = Knuckle Wall Mount Y = Dual Wattage Units
Connect Higher Wattage
Product Dimensions
TRUNNION MOUNTED
(Standard)
SLIPFITTER MOUNTED
(Options K or S)
WALL MOUNTED
(Option V)
• Approximate Net Weight: 43 lbs (20 kgs)
• Effective Projected Area From side: 1.0 sq ft max (.09 sq M max) At 45° horizontal (normal aiming angle): 3.0 sq ft max (.28 sq M max)
DATA
At 0° from horizontal: 4.3 sq ft max (.4 sq M max)
• Suggested Mounting Height: 20-60 ft (6-18 M)
GE Lighting Solutions 1-888-MY-GE-LED www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand and logo are trademarks of the General Electric Company. © 2012 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
OLP-2977 (Rev. 06/14/12)