GE GTV21GSSJWW, GTV21ESSJWW, GTX18ESSJWW, GTX18GSSJWW, GTD18GSSJWW Installation Guide

...
0 (0)

Installation

Dryers

Instructions

01

Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at: GEAppliances.com

This is the safety alert symbol. This symbol alerts you to potential hazards that can kill you or hurt you and others.

$OO VDIHW\ PHVVDJHV ZLOO IROORZ WKH VDIHW\ DOHUW V\PERO DQG WKH ZRUG ´'$1*(5µ ´:$51,1*µ RU ´&$87,21µ 7KHVH words are defined as:

DANGER

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

 

 

WARNING

Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

 

 

CAUTION

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

 

 

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT Save these instructions for local

electrical inspector’s use.

IMPORTANT Observe all governing codes and ordinances.

Install the clothes dryer according to the manufacturer’s instructions and local codes.

Note to Installer – Be sure to leave these instructions with the Consumer.

Note to Consumer – Keep these instructions for future reference.

Clothes dryer installation must be performed by a qualified installer.

This dryer must be exhausted to the outdoors.

Before the old dryer is removed from service or discarded, remove the dryer door.

Service information and the wiring diagram are located in the control console.

Do not allow children on or in the appliance. Close supervision of children is necessary when the appliance is used near children.

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the Warranty.

Install the dryer where the temperature is above 50°F for satisfactory operation of the dryer control system.

5HPRYH DQG GLVFDUG H[LVWLQJ SODVWLF RU PHWDO IRLO GXFW and replace with UL-listed duct.

 

 

 

 

 

 

 

 

 

 

 

WARNING

 

 

- Fire Hazard

 

 

 

Clothes dryer installation must be performed by a

 

 

 

 

qualified installer.

 

 

 

 

Install the clothes dryer according to these

 

 

 

 

instructions and local codes.

 

 

 

DO NOT install a clothes dryer with flexible plastic

 

 

 

 

venting materials. If flexible metal (semi-rigid or

 

 

 

 

foil-type) duct is installed, it must be UL-listed and

 

 

 

 

installed in accordance with the instructions found

 

 

 

 

in “Connecting the Dryer to House Vent” later in

 

 

 

 

this manual. Flexible vent materials are known to

 

 

 

 

collapse, be easily crushed and trap lint. These

 

 

 

 

conditions will obstruct dryer airflow and increase

 

 

 

 

the risk of fire.

 

 

 

 

DO NOT install or store this appliance in any

 

 

 

 

location where it could be exposed to water or

 

 

 

 

weather.

 

 

 

 

To reduce the risk of severe injury or death, follow

 

 

 

 

all installation instructions.

 

 

 

Save these instructions. (Installers: Be sure to leave

 

 

 

 

these instructions with the customer.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Printed in Mexico

234D2318P001

31-16767-1 05-15 GE

Installation Instructions

State of California Proposition 65 Warnings:

The California Safe Drinking Water and Toxic Enforcement Act requires the governor of California to publish a list of substances known to the state to cause cancer, birth defects or other reproductive harm and requires businesses to warn of potential exposure to such substances.

 

This product contains one or more chemicals known to the State of California to cause cancer, birth defects or

WARNING

other reproductive harm.

Gas appliances can cause low-level exposure to some of these substances, including benzene, carbon monoxide, formaldehyde and soot, caused primarily by the incomplete combustion of natural gas or LP fuels. Exposure to these substances can be minimized by properly venting the dryer to the outdoors.

UNPACKING YOUR DRYER

Tilt the dryer sideways and remove the foam shipping pads by pulling at the sides and breaking them away from the dryer legs. Be sure to remove all of the foam pieces around the legs.

5HPRYH OLWHUDWXUH DQG EDJ FRQWDLQLQJ DFFHVVRULHV

ROUGH-IN

 

27”

Y

 

DIMENSIONS

 

(68.8 cm)

 

 

Cubic

X

Y

 

 

 

Foot

 

 

 

 

 

 

 

 

6.0

43 3/8”

26 3/4”

X

 

X

(110 cm)

(68 cm)

 

 

 

 

 

7.0

43 3/8”

29 1/2”

 

 

 

(110 cm)

(75 cm)

 

 

 

 

 

 

 

7.3

43 3/4”

30 1/2”

 

 

 

(111 cm)

(78 cm)

 

 

 

 

 

 

 

 

 

 

 

 

4 5/8”

 

 

 

Front View

Side View

(11.7 cm)

 

 

 

4 1/4”

 

 

 

 

 

 

 

 

 

 

(10.8 cm)

STEAM WATER HOSES:

GE strongly recommends the use of factory specified parts.

Part Number

Accessory

WE25X20060

Complete Kit (hoses, Y-adapter

These hoses are manufactured and tested to meet GE

specifications.

OR

washers) (included)

GE strongly recommends the use of new water supply hoses.

 

WE1M847

Long Hose and

Hoses degrade over time and need to be replaced every 5

WE01X22395

Short Hose

years to reduce the risk of hose failures and water damage.

PM14X10056

Dryer door opening vent brush

Parts and Accessories

 

(not included)

Order on-line at GEApplianceParts.com, 24 hours a day or

WX14X10007

LintEater™ Dryer rotary tube brush

by phone at 800.626.2002 during normal business hours.

 

(not included)

2

Installation Instructions

REQUIREMENTS FOR ALCOVE OR CLOSET INSTALLATION

WARNING - Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18” (46 cm) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

If the dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.

The dryer MUST be vented to the outdoors. See

WKH (;+$867,1* 7+( '5<(5 VHFWLRQ

Minimum clearance between dryer cabinet and adjacent walls or other surfaces is:

0” either side 3” front

0” rear but a 1” minimum is recommended

Minimum vertical space from dryer to overhead shelves, cabinets, ceilings, etc., is 1” on top.

Consideration must be given to provide adequate clearance for installation and service.

Closet doors must be louvered or otherwise ventilated and have at least 60 square inches of open area. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 square inches of open area.

NOTE: WHEN THE EXHAUST DUCT IS LOCATED IN

7+( 5($5 2) 7+( '5<(5 7+( &21),*85$7,21 2) 7+( '8&7,1* 0$< 5(48,5( *5($7(5 7+$1 µ 2) 5($5&/($5$1&( $ µ0,1,080,65(&200(1'('

Gas Dryers Only:

No other fuel burning appliance shall be installed in the same closet as a gas dryer.

The dryer must be disconnected from the gas supply piping during pressure testing at pressures greater than ½ psi (3.5 kPa).

A 1/8 inch NPT minimum plugged tapping, accessible for test gauge connection, must be installed immediately upstream of the gas supply connection to the dryer.

MINIMUM CLEARANCE OTHER THAN ALCOVE OR CLOSET INSTALLATION

Minimum clearance to combustible surfaces and for air opening are: 0” both sides; 1” front; 0” rear but a 1” minimum is recommended. Consideration must be given to provide adequate clearance for installation and service.

MOBILE OR MANUFACTURED HOME INSTALLATION

Installation must conform to the

0$18)$&785(' +20( &216758&7,21 $1'

6$)(7< 67$1'$5' 7,7/( 3$57 ² RU

Standard CAN/CSA-Z240 MH, or, when such

VWDQGDUG LV QRW DSSOLFDEOH ZLWK $0(5,&$1

1$7,21$/ 67$1'$5' )25 02%,/( +20(

ANSI/NFPA NO. 501B.

The dryer MUST be vented to the outdoors. The exhaust vent must be securely fastened to a non-combustible portion of the mobile home.

The vent MUST NOT be terminated beneath a mobile or manufactured home.

The vent duct material MUST BE METAL.

KIT 14-D346-33 MUST be used to attach the dryer securely to the structure.

The vent MUST NOT be connected to any other duct, vent or chimney.

Do not use sheet metal screws or other fastening devices which extend into the interior of the exhaust vent.

Provide an opening with a free area of at least 25 square inches for introduction of outside air into the dryer room.

See the sections for electrical connection information.

POWER CORDS:

GE strongly recommends the use of factory specified parts. Select the power cord to fit your installation requirements.

Order on-line at GEApplianceParts.com, 24 hours a day or by phone at 800.626.2002 during normal business hours.

Part Number

Type

Length

Amperage

WX9X2

3-Prong

4 Feet

30

WX9X3

3-Prong

5 Feet

30

WX9X4

3-Prong

6 Feet

30

WX9X18

4-Prong

4 Feet

30

WX9X19

4-Prong

5 Feet

30

WX9X20

4-Prong

6 Feet

30

3

Installation Instructions

CONNECTING INLET HOSES

CONNECTING INLET HOSES

(on some models)

To produce steam, the dryer must connect to the cold water supply. Since the washer must also connect to the cold water, a “Y” connector is inserted to allow both inlet hoses to make that connection at the same time.

NOTE: Use the new inlet hoses provided; never use old hoses.

1 7XUQ WKH FROG ZDWHU IDXFHW RII 5HPRYH WKH washer inlet hose from the washer fill valve connector (cold).

2. Ensure the rubber flat washer is in place and attach one female coupling of the short hose onto the washer fill valve connector. Tighten by hand until firmly seated.

3. Attach one male end of the “Y” connector to the other female coupling of the short hose. Ensure the rubber flat washer is in place. Tighten by hand until firmly seated.

4. Insert the filter screen in the coupling of the washer’s inlet hose. If a rubber flat washer is already in place remove it before installing the filter screen. Attach this coupling to one male end of the ‘’Y’’ connector. Tighten by hand until firmly seated.

5. Ensure the rubber flat washer is in place and attach the dryer’s long inlet hose to one male end of the ‘’Y’’ connector. Tighten by hand until firmly seated.

6. Ensure the rubber flat washer is in place and attach the other end of the dryer’s long inlet hose to the fill valve connector at the bottom of the dryer back panel. Tighten by hand until firmly seated.

CONNECTING INLET HOSES

(on some models) (cont.)

7. Using pliers, tighten all the couplings with an

DGGLWLRQDO WZR²WKLUGV WXUQ

NOTE: Do not overtighten. Damage to the couplings may result.

8. Turn the water faucet on.

9. Check for leaks around the ‘’Y’’ connector, faucet and hose couplings.

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets MUST be installed within 42 in. (107 cm) of your washer’s water inlet. The faucets MUST be 3/4 in. (1.9 cm) garden hose-type so inlet hoses can be connected. Water pressure MUST be between 10 and 120 pounds per square inch. Your water department can advise you of your water pressure.

NOTE: A water softener is recommended to reduce buildup of scale inside the steam generator if the home water supply is very hard.

4

Installation Instructions

CONNECTING A GAS DRYER (skip for electric dryers)

TOOLS YOU WILL NEED

10” Adjustable

Flat-blade

wrenches (2)

screwdriver

8” Pipe wrench

Level

 

Slip-joint pliers

 

MATERIALS YOU WILL NEED

4” dia. metal elbow

4” dia., UL-listed

 

flexible metal duct

 

(if needed)

Pipe compound or

Gloves

PTFE tape

Flexible gas line

Soap solution for

connector

leak detection

Duct clamps (2) or

Exhaust hood

Spring clamps (2)

 

Safety glasses

Duct tape

 

4” dia. metal duct (recommended)

Gas pipe adapters (2), elbow and pipe plug

4” Cover Plate (Kit

WE1M454)

Before beginning the installation, turn off

the circuit breaker(s) or remove the dryer’s circuit fuse(s) at the electrical box. Be sure the dryer cord is unplugged from the wall.

Turn the dryer’s gas shut-off valve in the supply line to the OFF position.

Shut-off

Valve

Disconnect and discard old flexible gas connector and ducting material.

5

Installation Instructions

CONNECTING A GAS DRYER (skip for electric dryers) (cont.)

GAS REQUIREMENTS

WARNING - Explosion Hazard

Use a new CSA International approved flexible gas supply line. Never reuse old flexible connectors.

,QVWDOO D VKXW RII YDOYH6HFXUHO\ WLJKWHQ DOO JDV FRQQHFWLRQV

,I FRQQHFWHG WR /3 JDV KDYH D TXDOLILHG SHUVRQ make sure gas pressure does not exceed 13” water column.

([DPSOHV RI D TXDOLILHG SHUVRQ LQFOXGH OLFHQVHG heating personnel, authorized gas company personnel, and authorized service personnel.

)DLOXUH WR GR VR FDQ UHVXOW LQ GHDWK H[SORVLRQ or fire.

This gas dryer is equipped with a valve and burner assembly for use only with natural gas. Using conversion kit WE25X217, your local service organization can convert this dryer for use with propane (LP) gas. (To convert from propane (LP) to natural gas, conversion kit WE25X218 will be

XWLOL]HG $// &219(56,216 0867 %( 0$'( %< 3523(5/< 75$,1(' $1' 48$/,),(' 3(56211(/ $1' ,1 $&&25'$1&( :,7+ /2&$/ &2'(6 $1' 25',1$1&( 5(48,5(0(176

DRYER GAS SUPPLY CONNECTION

1-7/8"

3-1/8"

3/8" NPT MALE THREAD GAS SUPPLY

NOTE: Add to vertical dimension the distance between cabinet bottom to floor.

<RX PXVW XVH ZLWK WKLV GU\HU D IOH[LEOH PHWDO connector (listed connector ANSI Z21.24/CSA 6.10). The length of the connect shall not exceed 3 ft.

GAS SUPPLY

A 1/8” National Pipe Taper thread plugged tapping, accessible for test gauge connection, must be installed immediately upstream of the gas supply connection to the dryer. Contact your local gas utility should you have questions on the installation of the plugged tapping.

Supply line is to be 1/2” rigid pipe and equipped with an accessible shutoff within 6 feet of, and in the same room with, the dryer.

Use pipe thread compound appropriate for natural or LP gas or use PTFE tape.

Connect flexible metal connector to dryer and gas supply.

The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1.

IN THE COMMONWEALTH OF

MASSACHUSETTS

This product must be installed by a licensed plumber or gas fitter.

When using ball-type gas shut-off valves, they shall be the T-handle type.

A flexible gas connector, when used, must not exceed 3 feet.

ADJUSTING FOR ELEVATION

Gas clothes dryers input ratings are based on sea level operation and need not be adjusted for operation at or below 2000 ft. elevation. For operation at elevations above 2000 ft., input ratings should be reduced at a rate of 4 percent for each 1000 ft. above sea level.

Installation must conform to local codes and ordinances or, in their absence, the NATIONAL FUEL GAS CODE, ANSI Z223.

6

GE GTV21GSSJWW, GTV21ESSJWW, GTX18ESSJWW, GTX18GSSJWW, GTD18GSSJWW Installation Guide

Installation Instructions

CONNECTING THE DRYER TO THE GAS SUPPLY

AInstall a female 3/8” NPT elbow at the end of the dryer gas inlet.

Install a 3/8” flare union adapter to the female elbow.

IMPORTANT: Use a pipe wrench to securely hold on to the end of the dryer gas inlet to prevent twisting the inlet.

NOTE: Apply pipe compound or PTFE tape to the threads of the adapter and dryer gas inlet.

New Metal

 

 

Flexible Gas

 

Adapter

Line Connector

 

1/8” NPT

 

 

Adapter

 

Pipe Plug for

 

Checking Gas

Elbow

 

Inlet Pressure

 

 

Items not supplied

 

Shut-Off Valve

3/8” NPT

Pipe size at

 

least 1/2”

BAttach the flexible metal gas line connector to the adapter.

Apply pipe compound to the adapter and dryer gas inlet

CTighten the flexible gas line connection, using two adjustable wrenches.

CONNECTING THE DRYER TO THE GAS

SUPPLY (cont.)

DInstall a 1/8” NPT plugged tapping to the dryer gas line shut-off valve for checking gas inlet pressure.

Install a flare union adapter to the plugged tapping.

NOTE: Apply pipe compound or PTFE tape to the threads of the adapter and plugged tapping.

Apply pipe compound

 

or PTFE tape to all

 

male threads.

Plugged

 

Tapping

Shut-Off

Valve

ETighten all connections, using two adjustable wrenches. Do not overtighten.

F Open the gas shut-off valve.

7

Installation Instructions

CONNECTING A GAS DRYER (skip for electric dryers) (cont.)

TEST FOR LEAKS

Never use an open flame to test for gas leaks.

Check all connections for leaks with soapy solution or equivalent.

Apply a soap solution. The leak test solution must not contain ammonia, which could cause damage to the brass fittings.

If leaks are found, close the valve, retighten the joint and repeat the soap test.

Open Gas

Valve

ELECTRICAL CONNECTION INFORMATION FOR GAS DRYERS

WARNING - Electrical Shock Hazard

Plug into a grounded 3 prong outlet. DO NOT remove ground prong.

DO NOT use an adapter.

DO NOT use an extension cord.

Failure to do so can result in death, fire or electrical shock.

ELECTRICAL CONNECTION INFORMATION FOR GAS DRYERS (cont.)

The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/ NFPA 70 or Canadian Electrical Code, CSA C22.1

This appliance must be supplied with 120V, 60Hz, and be connected to a properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time delay fuse. If electrical supply provided does not meet these requirements, it is the owner’s responsibility to have a licensed electrician install a properly grounded 3-prong outlet.

Ensure proper ground exists before use.

If local codes permit an external ground wire (not provided) may be added by attaching to the green ground screw on the rear of the dryer, and to a grounded metal cold water pipe or other established ground.

Ground

Screw

8

Installation Instructions

CONNECTING AN ELECTRIC DRYER

(Skip for gas dryers and if your dryer already has a power cord attached)

TOOLS YOU WILL NEED

Before making the electrical connection, turn off

 

 

the circuit breaker(s) or remove the dryer’s circuit

 

 

fuse(s) at the electrical box. Be sure the dryer cord

 

 

is unplugged from the wall. 1(9(5 /($9( 7+(

Slip-joint pliers

Phillips screwdriver

$&&(66 &29(5 2)) 7+( 7(50,1$/ %/2&.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flat-blade crewdriver

Level

MATERIALS YOU WILL NEED

4” dia. metal elbow

3/4” strain relief (UL recognized)

4” duct clamps (2) or

4” spring clamps (2)

Safety glasses

4” dia. metal duct (recommended)

4” dia., UL-listed flexible metal duct (if needed)

Gloves

Exhaust hood

Duct tape

Dryer power cord kit (not provided with dryer)

UL rated 120/240V, 30A with 3 or 4 prongs. Identify the plug type as per the house receptacle before purchasing line cord.

4” Cover Plate (Kit WE1M454)

9

Installation Instructions

CONNECTING AN ELECTRIC DRYER (cont.)

(Skip for gas dryers and if your dryer already has a power cord attached)

ELECTRICAL CONNECTION INFORMATION FOR ELECTRIC DRYERS

For electrical connections using a power cord:

WARNING - Fire Hazard

Use a new UL-listed 240V 30 amp dryer power supply cord with closed ring terminals or spade terminals with upturned ends.

Use a UL-listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal.

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining two supply wires to remaining two terminals.

Securely tighten all electrical connections.

5HSODFH WKH WHUPLQDO EORFN FRYHU

Failure to do so can result in death, fire or electrical shock.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer: This dryer must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk

of electric shock by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Improper connection of the

WARNING equipment-grounding conductor can result in a risk of electrical shock. Check with a qualified electrician, or service representative or personnel, if you are in doubt as to whether the appliance is properly grounded. DO NOT modify the plug on the power supply cord. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

ELECTRICAL CONNECTION INFORMATION FOR ELECTRIC DRYERS

For direct wire connections:

WARNING - Fire Hazard

Use 10 gauge copper wire. Use a UL-listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal.

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining two supply wires to remaining two terminals.

Securely tighten all electrical connections.

5HSODFH WKH WHUPLQDO EORFN FRYHU

Failure to do so can result in death, fire or electrical shock.

GROUNDING INSTRUCTIONS

For a permanently connected dryer: This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-

grounding conductor must be run with the circuit conductors and connected to the equipmentgrounding terminal on the appliance.

Improper connection of the

WARNING equipment-grounding conductor can result in a risk of electrical shock. Check with a qualified electrician, or service representative or personnel, if you are in doubt as to whether the appliance is properly grounded.

SAVE THESE INSTRUCTIONS

10

Installation Instructions

CONNECTING DRYER USING 4-WIRE CONNECTION (MUST BE USED FOR MOBILE HOME INSTALLATION)

NOTE: Since January 1, 1996, the National Electrical Code requires that new constructions use a 4-wire connection to an electric dryer. A 4-wire cord must also be used where local codes do not permit grounding through the neutral.

3-wire connection is NOT for use on new construction.

5HPRYH JURXQG VWUDS

Hot

5HORFDWH

and discard. Keep

Wire

green

green ground screw

 

ground

 

 

screw

 

 

here

 

 

Green

 

Screws

Wire

 

 

 

(2)

 

 

Neutral

 

 

(white)

 

 

Screw

 

 

Hot

 

 

Wire

 

 

Fuse

 

Cover

Strain

3/4” UL

 

5HOLHI

5HFRJQL]HG

 

Bracket

6WUDLQ 5HOLHI

4 #10 AWG minimum copper conductors or 120/240V 30A power supply cord kit marked for use with dryers and provided with closed loop or spade terminals with upturned ends (not supplied).

1.Turn off the circuit breaker(s) (30 amp) or remove the dryer’s circuit fuse at the electrical box.

2.Be sure the dryer cord is unplugged from the wall receptacle.

3.5HPRYH WKH SRZHU FRUG FRYHU ORFDWHG DW WKH ORZHU EDFN

4. 5HPRYH DQG GLVFDUG JURXQG VWUDS .HHS WKH JUHHQ ground screw for Step 7.

5.Install 3/4 in. UL-recognized strain relief to power cord entry hole. Bring power cord through strain relief.

6.Connect power cord as follows:

A.Connect the 2 hot lines to the outer screws of the terminal block (marked L1 and L2).

B.Connect the neutral (white) line to the center of the terminal block (marked N).

7.Attach ground wire of power cord with the green ground screw (hole above strain relief bracket). Tighten all terminal block screws (3) securely.

8.Properly secure power cord to strain relief.

9. 5HLQVWDOO WKH FRYHU

NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK.

CONNECTING DRYER USING 3-WIRE CONNECTION

If required, by local code, install external ground (not provided) to grounded metal, cold water pipe, or other established ground determined by a qualified electrician.

 

Hot

 

 

Wire

 

Green Ground Screw

 

 

& Ground Strap

 

 

 

Screws

 

 

(2)

 

 

Neutral

 

 

(white)

 

 

Screw

 

 

Hot

 

 

Wire

 

 

Fuse

 

Cover

Strain

3/4” UL

 

5HOLHI

5HFRJQL]HG

 

Bracket

6WUDLQ 5HOLHI

3 #10 AWG minimum copper conductors or 120/240V 30A power supply cord kit marked for use with dryers and provided with closed loop or spade terminals with upturned ends (not supplied).

3-wire Connection

Not for use in Canada.

DO NOT use for Mobile Home Installations. NOT for use on new construction.

NOT for use on recreational vehicles.

NOT for use in areas where local codes prohibit grounding through the neutral conduction.

1.Turn off the circuit breaker(s) (30 amp) or remove the dryer’s circuit fuse at the electrical box.

2. Be sure the dryer cord is unplugged from the wall receptacle.

3.5HPRYH WKH SRZHU FRUG FRYHU ORFDWHG DW WKH ORZHU back.

4.Install 3/4-in. UL-recognized strain relief to power cord entry hole. Bring power cord through strain relief.

5.Connect power cord as follows:

A.Connect the 2 hot lines to the outer screws of the terminal block (marked L1 and L2).

B.Connect the neutral (white) line to the center of the terminal block (marked N).

6. Be sure ground strap is connected to neutral (center) terminal of block and to green ground screw on cabinet rear. Tighten all terminal block screws (3) securely.

7. Properly secure power cord to strain relief.

8. 5HLQVWDOO WKH FRYHU

NEVER LEAVE THE COVER OFF OF THE TERMINAL BLOCK.

11

Installation Instructions

EXHAUSTING THE DRYER

WARNING - Fire Hazard

This dryer MUST be vented to the outdoors.

Use only 4” rigid metal ducting for the home exhaust vent.

Use only 4” rigid metal or UL-LISTED transition duct to connect the dryer to the home exhaust duct.

DO NOT use a plastic vent.

DO NOT exhaust into a chimney, kitchen exhaust, gas vent, wall, ceiling, attic, crawl space, or concealed space of a building.

DO NOT install a screen in or over the exhaust duct.

DO NOT use duct longer than specified in the exhaust length table.

Failure to follow these instructions can result in death or fire.

TOOLS AND MATERIALS YOU WILL NEED TO INSTALL EXHAUST DUCT

Phillips-head screwdriver

Duct tape or duct clamp

5LJLG RU 8/ OLVWHG flexible metal 4” (10.2 cm) duct

Drill with 1/8” drill bit (for bottom venting)

Hacksaw

Vent hood

PARTS AVAILABLE FROM LOCAL

 

SERVICE ORGANIZATIONS

 

5LJLG 0HWDO 'XFW &RPSRQHQWV

 

WX8X63

4 x 1 Duct

 

WX8X64

4 x 2 Duct

 

WX8X51

4 Elbow

 

WX8X59

4 Aluminum Hood

 

Flexible Metal Duct Components

 

WX8X58

4 Clamps (2)

 

WX8X59

4 Aluminum Hood

 

WX08X10077 8/ /LVWHG )OH[LEOH 0HWDO 6HPL 5LJLG

 

 

Duct, 2 Clamps, 2 Close Elbows

 

WE1M454

Cover rear exhaust opening

12

 

 

 

 

CONNECTING THE DRYER TO HOUSE VENT

RIGID METAL TRANSITION DUCT

For best drying performance, a rigid metal transition duct is recommended.

5LJLG PHWDO WUDQVLWLRQ GXFWV UHGXFH WKH ULVN RI FUXVKLQJ and kinking.

UL-LISTED FLEXIBLE METAL CLOTHES DRYER TRANSITION DUCT

If rigid metal cannot be used, then UL-LISTED flexible

PHWDO FORWKHV GU\HU WUDQVLWLRQ GXFW *( SDUWV ²

PM08X10085, WX08X10085 or WX08X10077) can be used.

Never install transition duct in walls, ceilings, floors or other enclosed spaces.

Total length of transition duct should not exceed 8’ (2.4 m).

For many applications, installing elbows at both the dryer and the wall is highly recommended (see illustrations at right). Elbows allow the dryer to sit

close to the wall without kinking and/or crushing the transition duct, maximizing drying performance.

Avoid resting the duct on sharp objects.

UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT

In special installations, it may be necessary to connect the dryer to the home exhaust vent using flexible metal

IRLO W\SH WUDQVLWLRQ GXFW 8/²/,67(' XQLYHUVDO IOH[LEOH

GU\HU WUDQVLWLRQ GXFW *( SDUWV ² 30 ; RU :; ; may be used ONLY in installations where rigid metal or flexible metal transition ducting cannot be used AND where a 4” diameter can be maintained throughout the entire length of the transition duct.

In Canada and the United States, only transition ducts that

comply with “UL 2158A STANDARD FOR CLOTHES DRYER TRANSITION DUCT” shall be used.

Avoid resting the duct on sharp objects.

For best drying performance:

1.Slide one end of the duct over the clothes dryer outlet pipe.

2.Secure the duct with a clamp.

3.With the dryer in its permanent position, extend the duct to its full length. Allow 2” of duct to overlap the exhaust pipe. Cut off and remove excess duct. Keep the duct as straight as possible for maximum airflow.

4.Secure the duct to the exhaust pipe with the other clamp.

Loading...
+ 28 hidden pages