GTDX400GD
GE® 6.0 cu. ft. capacity DuraDrum™ gas dryer
Dimensions and Installation Information (in inches)
Exhaust Option: When viewed from the front of the unit, exhaust 3-way
via rear, left and bottom. Dryer is shipped exhausted to the rear. Alternate
exhausting knockouts are supplied.
Gas: An individual, properly-grounded branch circuit, with a three-prong
grounding-type receptacle, protected by a 15 or 20 amp circuit breaker or a
time-delay fuse is required.
Gas Dryer Electric Rating: 120V, 60Hz, 6A
Gas (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas. LP
gas supply requires a conversion kit. Check installation instructions for correct
kit and have a qualified gas technician install a conversion kit. See dryer
ducting information for proper installation.
Note: Dryer wall outlet must be located within 36" of service cord entry and
accessible when dryer is mounted in position.
Installation Information: For complete information, see installation instructions
packed with your dryer.
Special Installation Requirements
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label
on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side; 3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of
60 sq. in. of open area equally distributed. If this closet contains both a washer and a
dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
geappliances.com or call GE Answer Center®
service, 800.626.2000.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with
the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
Dryer Exhausting Information : Use metal duct only, vertical and
horizontal ducting.
Specification Revised 3/14
370238
GTDX400GD
GE® 6.0 cu. ft. capacity DuraDrum™ gas dryer
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4" diameter all rigid metal
exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semirigid) ducting can be used (Kit WX08X10077). In special installations, it may be
necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct.
A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid
metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4” diameter
can be maintained throughout the entire length of the transition duct. Please see
installation instruction packed with your dryer for complete instructions when using
flexible metal (foil type) ducting.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the
side or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated
is shown in the table. A turn of 45° or less may be ignored. Two 45° turns within the
duct length should be treated as a 90° elbow. A turn over 45° should be treated as a
90° elbow.
Dryers must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any
enclosed house floor (crawl space), or into an attic, since the accumulated lint could
create a fire hazard or moisture could cause damage. Never terminate the exhaust
into a common duct or plenum with a kitchen exhaust, since the combination of lint
and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts,
bird nesting, etc. The wall cap must also be located at least 12" above the ground or
any other obstruction with the opening pointed down.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
Dryer exhausting information—use metal
duct only vertical and horizontal ducting
Best performance
Maximum length
A
Number
Domestic dryer models
GE Frontload Long Vent 7.0
cu. ft. capacity electric dryer
(GFDL)
All Long Vent 6.0 - 8.0 cu. ft.
capacity electric & gas dryers
(GTDL)
All 6.0 - 8.3 cu. ft. capacity
models electric and gas dryers
(GFDS, GFDR, GFDN, GTDS,
GTDN, GHDN, GHDS, GTDP,
GLDP, GTDX, HTDP, HTDX)
DCVH480
All 3.6 cu. ft. (DSKS, DSKP)
electric dryers
Laundry Center GTUP270,
GTUN275
Laundry Center GTUP240
For every extra 90° elbow, reduce the allowable vent system length by 10 ft.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to the chart.
The total vent system length includes all the straight portions and elbows of the system (transition
duct included).
Laundry Center length includes factory-installed elbow that does not impact vent length.
of 4" dia rigid
metal duct
Exhaust hood type
of 90°
turns
0 200 ft. 175 f t.
1 185 ft. 165 f t.
2 175 ft. 155 ft.
3 165 f t. 145 ft.
4 155 ft. 135 f t.
5 145 ft. 125 ft.
0 150 ft. 125 ft.
1 135 f t. 115 ft.
2 125 ft. 105 ft.
3 115 ft. 95 ft.
4 105 ft. 85 ft.
5 95 ft. 75 ft.
0 90 ft. 60 ft.
1 60 ft. 45 ft.
2 45 ft . 35 f t.
3 35 ft. 25 ft.
4 25 ft. 15 ft.
0 90 ft. 60 ft.
1 60 ft. 45 ft.
2 45 ft . 35 f t.
3 35 ft. 25 ft.
0 46 ft. 37 f t.
1 37 ft. 30 ft.
2 30 ft. 22 f t.
3 23 ft. 15 ft.
0 56 ft. 42 ft.
1 48 ft. 34 ft.
2 40 ft. 26 ft.
3 32 ft. 18 ft.
0 43 ft. 36 ft.
1 33 ft . 26 ft.
2 24 f t. 16 ft.
A
4"
opening
Specification Revised 3/14