GE DHDSR46GG9WW, DNCK440GG9WC, GHDN520GD0WS, GHDN520GD1WS, GHDN520GD2WS Installation Guide

...
Installation
Instructions l'°so r'er1@
Questions on Installation? Call: 800.GE.CARES (US)
or visit our web site at: www.GEAppliances.com (US)
BEFOREYOU BEGIN
Read these instructions completely and
carefully.
IN PORTANT-Save these instructions for
IMPORTANT- Observe all governing codes
and ordinances.
Note to Installer - Besureto leavethese instructionswith the customer.
Note to Customer - Keep these instructions with your Owner's Hanual for future reference.
Before the old dryer is removed from service or discarded, remove the dryer door.
inspect the dryer exhaust outlet and straighten the outlet walls if they are bent.
Service information and the wiring diagram
are locatedin thecontrolconsole.
Donot allowchildren on or inthe appliance. Closesupervisionof childrenis necessarywhen theappliance isusednear children.
installthe dryer wherethe temperatureis aboveSO°Ffor satisfactory operationofthe dryercontrol system.
Productfailuredue to improper installationis not coveredunderthe Warranty.
WARNING RISK OF FIRE
To reducethe risk ofsevereinjuryor death, follow all installationinstructions.
Clothesdryer installationmust be performed bya qualifiedinstaller.
Installthe clothesdryer accordingto theseinstructionsand inaccordance with local codes.Inthe absenceof localcodes,installationmust complywith National FuelGas Code,ANSIZ22].l/NFPA54or the CanadianNaturalGasand PropaneInstallationCode,
CSAB149.1.
CaliforniaSafeDrinkingWaterand ToxicEnforcementAct.
Thisact requiresthe governor of Californiato publish alistof substancesknownto the
state tocause cancer,birth defectsor other reproductiveharm and requiresbusinesses to warn customersofpotential exposureto suchsubstances.Gasappliancescan
causeminor exposuretofour of thesesubstances,namelybenzene,carbonmonoxide,
formaldehydeand soot, causedprimarily by the incompletecombustionof naturalgas
or LPfuels.Properlyadjusted dryerswitiminimizeincompletecombustion. Exposure
to these substancescan beminimizedfurther byproperlyventingthe dryerto the
outdoors.
Thisdryer must be exhaustedto the outdoors.
Useonly4" rigid metalducting for exhaustingthe clothesdryer to the outdoors.
DONOTinstall aclothesdryer with flexible plasticducting materials.If flexiblemetal (semi-rigidorfoil-type) duct isinstalled,itmustbe ULlisted andinstalledin accordance
with the instructionsfound in "ConnectingTheDryerToHouseVent" onpage6 ofthis
manual.Flexibleventing materials areknownto collapse,beeasiiy crushed,and trap lint.Theseconditionswilt obstruct dryerairflow and increasethe riskof fire.
Donot installor store this appliancein any locationwhere it could beexposedto water andorweather.
Savetheseinstructions.(Installers:Besureto leavethese instructionswith the customer).
In the state of Massachusetts:
Installation must beperformed by a qualified or licensedcontractor, plumber,or gasfitter qualified or licensedby the state.
Whenusing ball-type gasshut-offvalves, they shall beT-handletype.
Aflexible gasconnector, when used,must not exceed3 feet.
TOOLS YOU
WILL NEED
(x2)
10"ADJUSTABLEWRENCHES
, ic................._)
8"PIPEWRENCH LEVEL
SLIPJOINTPLIERS FLATBLADESCREWDRIVER
Step 1Verify Your Gas Installation (see section 2). Step 2 Prepare the Area and Exhaust for Installation of
New Dryer (see section 1).
Step ] Check and Insure the Existing External Exhaust is
Clean (see section 1) and Meets Attached Installation Specifications (see section 6).
Step 4 Remove the Foam Shipping Pads (see section 1). Step 5 Move the Dryer to the Desired Location.
Step 6 Level Your Dryer (see section 8). Step 7 Connect the Gas Supply (see section ]) and check for
leaks (see section 4).
4"DIA.METALDUCT I====_
(RECOMMENDED)
4"DIA.FLEXIBLEMETAL(SEMI-RIGID)
ULLISTEDTRANSITIONDUCT
KITWXO8X10077(INCLUDES2ELBOWS)
4"DIA.FLEXIBLEMETAL(FOILTYPE)
(IFNEEDED)
ULLISTEDTRANSITIONDUCT
(IFNEEDED.)
MATERIALSYOUWILLNEED
)
4"DIAMMETALELBOW
4"DUCTCLAMPS DUCTTAPE
OR SAFETYGLASSES
4"SPRINGCLAMPS
Step 8 Connect the External Exhaust (see section 7). Step 9 Connect the Power Supply (see section 5).
Step 10 Check the Operation of the Power Supply, Gas
Connections, and Venting.
Step 11 Place the Owner's Manual and the Installation
Instructions in a location where they will be noticed by the owner.
For Alcove or Closet Installation see section 9. For Bathroom or Bedroom Installation see section 10.
For Mobile or Manufactured Home see section 11. For garage installation (if allowed by local codes), see section 12.
EXHAUSTHOOD COMPOUND
FLEXIBLEGASLINECONNECTOR GLOVES
PIPE
SOAPSOLUTION
FORLEAKDETECTION
234D1582PO03 31-16225-2 03-12 GE
Installation Instructions
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and J_in. rear.
Consideration must be given to provide adequate clearance for installation and service.
[] PREPARING FOR INSTALLATION
OF NEW DRYER
TIP:Install your dryer before installing your washer. This will allow better access when installing dryer
exhaust.
DISCONN_TING GAS
TURNGAS
SHUT-OFFVALVE1(7_ DISCONNECTANDDISCARDOLD
TOTHEOFF
POSITION.x'_ _--_ OLDTRANSITIONDUCTING
_u FLEXIBLEGASCONNECTORAND
MATERIAL,REPLACEWITHNEW CSA(AGA)APPROVEDFLEXIBLE
GASLINECONNECTORANDUL APPROVEDTRANSITIONDUCT.
WARNING - NEVERREUSEOLD
FLEXIBLE CON NECTORS. The use of old flexible connectors can cause leaks
and personal injury. Always use new flexible connec- tors when installing gas appliances.
REMOVING LINT FROM WALL EXHAUST OPENING
[] GAS REQUIREMENTS
tLWARNING
Installation must conform to local codes and
ordinances, or in their absence, the NATIONAL FUEL GASCODE,ANSI Z223.
This gas drger is equipped with a Valve & Burner
Assemblg for use onlg with natural gas. Using conversion kit WE25X0217, gour local service organization can convert this drger for use with propane (LP)gas. ALL CONVERSIONSMUSTBEMADE BY PROPERLYTRAINED AND QUALIFIEDPERSONNELAND
IN ACCORDANCEWITH LOCALCODESAND ORDINANCE REQUIREMENTS.
The dryer must be disconnected from the gas supply
piping system during any pressure testing of that system at a test pressure in excess of O.5PSI(3.4 KPa).
The dryer must be isolated from the gas supply piping
system bg closing the equipment shut-off valve during ang pressure testing of the gas supply piping of test pressure equal to or less than 0.5 PSI(3.4 KPa).
DRYERGASSUPPLYCONNECTION
Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition
duct.
WALL
INTERNALDUCT OPENING HOODDAMPEROPENS
CHECKTHATEXHAUST
ANDCLOSESFREELY.
TILTTHE DRYERSIDEWAYS AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING ATTHE SIDES AND BREAKING THEM AWAY FROM THE DRYER
LEGS.BE SURETO
REMOVEALL OFTHE
FOAM PIECESAROUND THE LEGS.
A 2-5/8" 3/8"NPTMALETHREADGASSUPPLY
NOTE:Addtoverticaldimension
thedistancebetweencabinet
;AS SUPPLY
bottomtofloor.
A 1/8-in.National PipeTaper thread plugged tapping, accessible for test gauge connection, must be installed immediately upstream of the gas supply connection to the dryer. Contact your local gas utility should you have questions on the installation of the plugged tapping. Supply line is to be 1/2-in. rigid pipe and equipped with an accessible shut-off within 6 ft. of, and in the same room with the dryer.
Use pipe thread sealer compound or Teflon tape appro- priate for natural or LPgas. You must use with this dryer a flexible metal connector listed connector ANSIZ21.24/CSA 6.10.The length of the
connect shall not exceed 3 ft. Connect flexible metal connector to dryer and gas supply.
Open shut-off valve.
ADJUSTING FOR ELEVATION
Gasclothes dryers input ratings are based on sea level operation and need not be adjusted for operation at or
below 2000 ft. elevation. For operation at elevations above 2000 ft., input ratings
should be reduced at a rate of 4 percent for each lO00 ft. above sea level.
Installation must conform to local codes and ordinances or, in their absence,the NATIONALFUELGASCODE,ANSIZ223.
2
Installation Instructions
IYI RECONNECTING GAS
Listed connector ANSt Z21.24 / CSA 6.10
1/8" NPT PIPE
NEW METAL PLUG FOR FLEXIBLEGAS INLETPRESSURE
LINECONNECTOR
ADAPTER
3/8" NPT
ELBOW
ITEMSNOT SUPPLIED _AT LEAST1/2"
Note: The connector and fittings are designed for use only on the original installation and are not to be reused for another appliance or at another location. Keep flare end of adaptor free of grease, oil and thread sealant.
GAS
SHUT-OFF
PIPE SIZE
APPLYPIPECOMPOUND
TOALL MALETHREADS.
CAUTION: Use adapters as shown. Connector
nuts must not be connected directly to pipe threads.
APPLYPIPECOMPOUND TOTHEADAPTERAND
DRYERGASINLET.
TIGHTENTHE FLEXIBLE"_
GASLINEUSINGTWO_ I
TIGHTEN ALL CONNECTIONS
USINGTWO ADJUSTABLE WRENCHES. DO NOT OVERTORQUE GAS CONNECTIONS!
I%-1LEAK TEST
WARNING: NEVERUSEANOPEN
FLAME TO TEST FOR GAS LEAKS.
OPEN
GASVALVE.
ADJUSTABLEWRENCHE& _
Check all connections for teoks with soopg solution or equivalent. Apptg soap solution. Leek test solution must not contain ammo-
niawhich could cause damage to the brass fittings.IfleaksGre
found, close v(]lve, retighten the joint, and repeat the soap test.
3
Installation Instructions
[] ELECTRICAL CONNECTION
INFORMATION
WARNING - TOREDUCETHE
RISK OF FIRE, ELECTRICAL SHOCK,
AND PERSONAL INJURY:
DO NOT USEAN EXTENSIONCORDORAN ADAPTER PLUGWITH THIS APPLIANCE.
Dryer must be electrically grounded in accordance with local codes and ordinances, or inthe absence of local codes, in accordance with the NATIONAL
ELECTRICALCODE,ANSI/NFPANO.70.
ELECTRICAL REQUIREMENTS
This appliance must be supplied with 120V,60Hz, and connected to a properly grounded branch circuit,
protected by a 15- or 20- amp circuit breaker or time- delay fuse. If electrical supply provided does not meet the above specifications, it is recommended that (] licensed electrician install an approved outlet.
WARNING - THISDRYERIS
EQUIPPED A THREE-PRONG (GROUNDING) PLUG FOR YOUR PROTECTION AGAINST
SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. DO NOT CUT
OR REMOVE THE GROUNDING PRONG FROM THIS PLUG.
I-_ EXHAUST INFORMATION
WARNING -IN CANADA AND IN THE
UNITED STATES,THE REQUIRED EXHAUST DUCT DIAMETER IS 4 IN (102mm). DO NOT USEDUCT LONGER THAN SPECIFIED IN THE EXHAUST
LENGTH TABLE. Usingexhaustlongerthan specifiedlengthwill:
increasethedrying timesand theenergycost. Reducethe dryerlife.
Accumulatelint,creatinga potential firehazard. Thecorrect exhaustinstallation isYOURRESPONSIBILITY.
Problemsdueto incorrect installation are not covered by the warranty.
Removeanddiscardexisting plasticor metalfoil transition duct and replacewith ULlistedtransition duct.
TheMAXIMUMALLOWABLEduct lengthand numberof bendsof theexhaust systemdependsuponthetype of duct, numberof turns,the type of exhausthood (wallcap),and all conditionsnoted below.Themaximumduct length for rigid
metal duct isshowninthetable below.
EXHAUST LENGTH
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90° Rigid,
Elbows Hetal
0 60 Feet 1 45 Feet
2 35 Feet 3 25 Feet
Rigid,
Metal
90 Feet 60 Feet
45 Feet 35 Feet
Use only for short
run installations
4" DIA
.......II-.
ENSUREPROPERGROUND EXISTSBEFOREUSE.
IF LOCAL CODES PERMIT, AN EXTERNAL GROUND WIRE (NOT PROVIDED), WHICH MEETS
LOCAL CODES, MAY BE ADDED
BYATTACHING TO THE GREEN GROUND SCREW ON THE REAR
OF THE DRYER, AND TO A GROUNDED
METAL COLD WATER PIPE OR OTHER
ESTABLISHED GROUND.
EXHAUST SYSTEM CHECK LIST
HOOD ORWALL CAP
Terminateina mannerto preventback draftsor entry of birds or otherwildlife.
Terminationshouldpresentminimalresistanceto the exhaust air flow and shouldrequirelittleor nomaintenanceto prevent
clogging.
Neverinstalla screenin or overtheexhaustduct.Thiscould causelint buildup.
Wallcapsmust beinstalledat least12in. abovegroundlevel or anyother obstructionwith the openingpointeddown.
SEPARATIONOFTURNS Forbest performance,separateallturns byat least4ft. of straightduct, includingdistance betweenlastturn andexhaust
hood.
TURNSOTHERTHAN900
Oneturn of 450or lessmaybe ignored.
Two450turnsshouldbetreated as one 900turn.
Eachturn over450shouldbetreated asone 900turn.
SEALINGOFJOINTS
Alljointsshouldbetight to avoidleaks.Themale endof each sectionof duct must pointawayfrom thedryer.
Donotassemblethe ductwork with fastenersthat extend into the duct. Theywill serveasa collectionpointfor lint.
Ductjoints canbe madeair andmoisture-tightbywrapping the overlappedjoints with duct tape.
Horizontal runs should slope down toward the outdoors
1/4 inch per foot.
INSULATION Ductwork that runsthroughanunheatedareaor is near air
conditioningshouldbeinsulatedto reducecondensationand lintbuild-up.