BEFORE YOU BEGIN
Readtheseinstructionscompletelyendcarefully.
inspector's use.
IMPORTANT- Observe all governing codes and ordinances.
Noteto Installer - Besureto leavetheseinstructionswith the customer.
Noteto Customer- Keeptheseinstructionswithyour Owner's Manualfor future reference.
Before the old dryer is removed from serviceor discarded, removethe dryer door.
Inspect the dryer exhaust outlet and straighten the outlet
walls ifthey are bent.
Serviceinformation andthe wiring diagram are locatedinthe controlconsole.
Donot allowchildrenonor in theappliance.Closesupervision of children is necessary when the appliance is used near
children.
Install the dryer where the temperature is above 50°F for satisfactoryoperation ofthe dryercontrol system. Product failure due to improper installation is not covered under the warranty.
01
WARNING RISK OF FIRE
, To reduce the risk of severe injury or death, follow all
installation instructions. Clothes dryer installation must be performed by a
qualified installer.
Install the clothes dryer according to these instructions
and in accordance with local codes. This dryer must be exhausted to the outdoors.
Use only 4" rigid metal ducting for exhausting the
clothes dryer to the outdoors.
DONOTinstall a clothes dryer with flexible plastic ducting materials. If flexible metal (semi-rigid or foil-type) duct is installed, it must be ULlisted and installed in accordance with the instructions found in Connecting The Dryer To House Vent on page 5 of this manual. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct dryer airflow and
increase the risk of fire.
Do not install or store this appliance in any location where it could be exposed to water and or weather. Save these instructions. (Installers: Be sure to leave these instructions with the customer).
Install the clothes dryer according to the manufacturer's instructions and local codes.
NOTE: Installation and service of this dryer
requires basic mechanical and electrical
skills. It is your responsibility to contact a qualified installer to make the electrical
connections.
TOOLS YOU WILL NEED
SLIPJOINTPLIERS
FLATBLADESCREWDRIVER
Step ! Prepare the Area and Exhaust for Installation of
New Dryer (seesection 1).
Step 2 Check and Ensure the Existing External Exhaust is Clean (seesection 1)and MeetsAttached Installation
Specifications (seesection 3). Step 3 Remove the Foam Shipping Pads (seesection 1). Step 4 Hove the Dryer to the Desired Location. Step 5 Connect the Power Supply (see section 2). Step 6 Connect the External Exhaust (seesection 4).
PHILLIPSSCREWDRIVER
MATERIALS YOU WILL NEED
4"DIAFLEXIBLEMETAL(SEMI-RIGID)
KITWXOBX1BB77(INCLUDES2ELBOWS)
4"DIAFLEXIBLEMETAL(FOILTYPE)
4"DIAM_TALDUCT V/ll
(RECOMUENDED)
ULLISTEDTRANSITIONDUCT
(IFNEEDED)
ULLISTEDTRANSITIONDUCT(IFNEEDED)
Step 7 Level Your Dryer (seesection 5). Step 8 Check the Operation of the Power Supply & Venting. Step 9 Place Owner's Manual and Installation Instructions in a location where they will be noticed by the owner.
For Alcove or Closet Installation, see section 6. For Bathroom or Bedroom Installation, see section 7. For Mobile or Manufactured Home see, section 8. Forgarage installation (ifallowed bylocalcodes),seesection9.
For side or bottom exhaust, see section 10.
8"DUCT #'DIA METAL
CLAMPS(2) ELBOW
OR
#'SPRING
CLAMPS(2)
"--L4J
EXHAUST SAFETY
HOOD GLASSES
DUCTTAPE GLOVES
3/4"STRAIN
RELIEF
ULRECOGNIZED
DRYERPOWER
CORDKIT
(NOTPROVIDED
WITHDRYER) ULRATED 120/240V3OA
WITH3OR4PROGS IDENTIFYTHEPLUG
TYPEASPERTHE HOUSERECEPTACLE BEFOREPURCHASING
LINECORD
IIIIIIIIIIIiill
234D22JGPOOJ
3"1-'16734 JO-J5 GE
IIIIII
Installation instructions
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and i in. rear.
Consideration must be given to provide adequate clearance for installation and service.
FIIPREPARING FOR INSTALLATION OF
NEW DRYER
TIP: Install your dryer before installing your washer. This will allow better access when installing dryer
exhaust.
REMOVING LINT FROM WALL EXHAUST OPENING
, Remove and discard existing plastic or metal
foil transition duct and replace with UL listed transition duct.
WALL
INTERNALDUCT
OPENING ../HOODDAMPEROPENS
CHECKTHATEXHAUST
ANDCLOSESFREELY.
TILTTHE DRYERSIDEWAYS AND REMOVETHE FOAM SHIPPING PADS BY
PULLING ATTHE SIDES AND BREAKING THEM AWAY FROM THE DRYER LEGS. BESURETO
REMOVEALL OF THE FOAM PIECESAROUND THE LEGS,
CONNECTING DRYER USING 4-WIRE CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTES: Since January :1, :1996, the National Electric code requires that the new constructions utilize a
4-wire connection to an electric dryer.
WARNING: Onlyo 4-conductorcordshall
be used when the appliance is installed in a location
where grounding through the neutral conductor is
prohibited. Grounding through the neutral is prohibited
for the new branch-circuit installations, mobile homes,
recreational vehicles, and areas where local codes prohibit grounding through the neutral conduction.
Remove ground strop _ Hot Relocote
and discord, Keep [ ___._Wire green green ground screw _ _ ,/ _'--_k ground
, _/.._. "_ here
_ Hot _;/. V_I. .
F21ELECTRICAL CONNECTION INFORMATION
t WARNING - TOREDUCETHE
RISKOF FIRE, ELECTRICAL SHOCK AND
PERSONAL INJURY: ,, DO NOT USE AN EXTENSION CORD OR AN
ADAPTER PLUG WITH THIS APPLIANCE.
Dryer must be electrically grounded in accordance with
local codes and ordinances, or in the absence of local codes,in accordance with the NATIONALELECTRICAL CODE,ANSI/NFPANO.70.
ELECTRICAL REQUIREMENTS
This dryer must be connected to an individual branch circuit,
protected by the requiredtime-delay fusesor circuit breakers.
A four or three-wire, single phase, 120/240V or 120/208V,
60Hz,:30amp circuit isrequired.Ifthe electricsupply doesnot meet the above specifications,then call a licensedelectrician.
GROUNDING INSTRUCTIONS
Thisdryer must beconnectedto agrounded metal,permanent wiring system, or an equipment-grounding conductor must
be run with the circuit conductors and connected to the equipment-grounding terminal onthe appliance.
c I _ I I_-j
over_ } _ Stroin 3/4" UL
-- _ Bracket Stroin Relief
4 #t0 AWG minimum copper conductors or 120/240V 30A power supply cord kit marked for usewith dryers and provided with closed loop or spode terminals with upturned ends (not supplied).
/ I Relief Recognized
!. Turn off the circuit breaker(s)(30 amp)or remove the
dryer's circuit fuse at the electrical box,
2.Be sure the dryer cord is unplugged from the wall receptacle,
3.Removethe power cord cover located at the lower back.
4.Remove and discard ground strap. Keep the green ground screw for step 7.
5.Install 3/4 in. UL recognized strain relief to power cord entry hole. Bring power cord through strain relief.
6.Connect power cord as follows:
A.Connect the 2 hot lines to the outer screws of
the terminal block (marked L! and L2).
B.Connect the neutral (white) lineto the center of
the terminal block (marked N).
7.Attach ground wire of power cord with the green ground screw (hole above strain relief bracket). Tighten all terminal block screws (3)securely.
8.Properly secure power cord to strain relief.
9.Reinstall the cover.
COVER OFF OF THE TERMINAL BLOCK.
I WARNING: NEVER LEAVE THE !
2
Installation instructions
CONNECTING DRYER USING 3-WIRE CONNECTION
If required, by local code, install external ground {not provided) to
grounded metal, cold water pipe, or other established ground determined by a qualified electrician.
Hot
Wire
Green Ground Screw
& Ground Strap
Fuse
Cover
3 #10 AWG minimum copper conductors or 120/240V 30A power supply cord kit marked for usewith dryers and provided with closed loop or spade terminals with upturned ends (not supplied).
Strain 3/4" UL
Relief Recognized Bracket Strain Relief
3-wire Connection
Not for use in Canada. DONOTuse for Mobile Home Installations. NOTfor use on new construction. NOTfor use on recreational vehicles.
NOTfor use in areas where local codes prohibit grounding
through the neutral conduction.
1.Turn off the circuit breaker(s)(30 amp) or remove the dryer's circuit fuse at the electrical box.
2.Be sure the dryer cord is unplugged from the wall.
3.Remove the power cord cover located at the lower back.
4. Install 3/4 in. UL recognized strain relief to power cord entry hole. Bring power cord through strain relief.
5.Connect power cord as follows: A. Connect the 2 hot lines to the outer screws of
the terminal block (marked L1 and L2).
B.Connect the neutral (white) line to the center of
the terminal block (marked N).
6.Be sure ground strap is connected to neutral (center)
terminal of block and to green ground screw on cabinet rear.Tighten all terminal block screws (3)securely.
7.Properly secure power cord to strain relief.
8. Reinstall the cover.
WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
[-3]EXHAUST INFORMATION
i WARNING -INCANADAANDINTHE
UNITED STATES, THE REQUIRED EXHAUST DUCT DIAMETER IS 4 IN (102mm). DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE.
Usingexhaust longer than specified length will: . Increasethe drying times andthe energy cost. , Reducethe dryer life. , Accumulate lint, creating a potential fire hazard.
Thecorrect exhaust installation isYOUR
RESPONSIBILITY.Problems due to incorrect installation are not covered by the warranty.
Removeand discard existing plasticor metal foil transition duct and replacewith ULlisted transition duct. TheMAXIMUMALLOWABLEduct length and number of bends of the exhaust systemdepends upon the typeof duct, number of turns,the type of exhaust hood (wallcap), and all conditions noted below.The maximum duct length for rigid metal duct isshown inthe table below.
EXHAUST LENGTH
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended Use only for short
......14I....... I I--2"2
No. of 90 ° Rigid Rigid
EIb ows Metal Metal
0 90 Feet 60 Feet
1 60 Feet 45 Feet 2 45 Feet 35 Feet 3 35 Feet 25 Feet
4 25 Feet 15 Feet
. Forevery extra 90°elbow, reduce the allowable vent system
length by 10ft.
. Two/45°elbows will betreated likeone 90°elbow. . Forthe side exhaust installations, add one 90° elbow to the
chart.
, Thetotal vent system length includesallthe straight portions
and elbows of the system (transitionduct included).
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
, Terminate in a manner to prevent back drafts or entry of
birdsor other wildlife.
. Termination should present minimal resistance to the
exhaust air flow and should requirelittle or no maintenance to prevent clogging.
. Never install a screenin or overthe exhaustduct. Thiscould
cause lint build up.
, Wall caps must be installed atleast !2 in. above ground
level or any other obstruction with the opening pointed
down.
SEPARATIONOFTURNS
For best performance, separate all turns by at least 4 ft.
of straight duct, including distance between last turn and exhaust hood.
TURNSOTHERTHAN90°
. Oneturn of 450orlessmay be ignored. . Two 450turns should be treated as one 900turn.
. Eachturn over 450should betreated as one 900turn.
run installations
3