GTDP180GD
GE® 6.8 cu. ft. capacity DuraDrum™ gas dryer
Dimensions and Installation Information (in inches)
Exhaust Options: When viewed from the front of the unit, exhaust 3-way
via rear, left and bottom. Dryer is shipped exhausted to the rear. Alternate
exhausting knockouts are supplied.
Electric: An individual, properly-grounded branch circuit, with a three-prong
grounding-type receptacle, protected by a 15 or 20 amp circuit breaker or a
time-delay fuse, is required.
Gas Dryer Electric Rating: 120V, 60Hz, 6A
Gas (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas.
LP gas supply requires a conversion kit. Check installation instructions for
correct kit and have a qualified gas technician install a conversion kit.
See dryer ducting information for proper installation.
Note: Dryer wall outlet must be located within 36” of service cord entry and
accessible when dryer is mounted in position.
Installation Information: For complete information, see installation
instructions packed with your dryer.
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on
a label on the dryer back.
• The dryer MUST be exhausted to the outside
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces
are: 0" either side and 3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
• Closet doors must be louvered or otherwise ventilated and must contain a
minimum of 60 sq. in. of open area equally distributed. If this closet contains both
a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area
equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a
ga s dryer.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Specification Revised 3/14
Listed by
Underwriters
Laboratories
370132
GTDP180GD
GE® 6.8 cu. ft. capacity DuraDrum™ gas dryer
Special Installation Requirements
Ducting Materials: 4-way via rear, right, left and bottom.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust
to the side or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be
tolerated is shown in the table. The maximum length for flexible ducts are
less than for rigid duct.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should
be treated as a 90° elbow.
A turn over 45° should be treated as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended to prevent large
amounts of moisture and lint from being blown into the room. Gas dryers or any
dryer located in a closet must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any
enclosed house floor (crawl space), or into an attic, since the accumulated lint could
create a fire hazard or moisture could cause damage. Never terminate the exhaust
into a common duct or plenum with a kitchen exhaust, since the combination of lint
and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts,
bird nesting, etc. The wall cap must also be located at least 12" above the ground or
any other obstruction with the opening pointed down.
Other terminations, such as louvered wall boxes, are acceptable provided they are
equivalent to a 4" opening dampered wall cap.
For more information on venting kits and accessories, please call 1-800-GE CARES.
Listed by
Underwriters
Laboratories
Dryer exhausting information—use metal
duct only vertical and horizontal ducting
Best performance
Maximum length
A
Number
Domestic dryer models
GE Frontload Long Vent 7.0
cu. ft. capacity electric dryer
(GFDL)
All Long Vent 6.0 cu. ft.
capacity electric & gas dryers
All 6.0 - 8.3 cu. ft. capacity
models electric and gas dryers
(GFDS, GFDR, GFDN, GTDS,
GTDN, GHDN, GHDS, GTDP,
GLDP, GTDX, HTDP, HTDX)
DCVH480
All 3.6 cu. ft. (DSKS, DSKP)
electric dryers
Laundry Center GTUP270,
GTUN275
Laundry Center GTUP240
For every extra 90° elbow, reduce the allowable vent system length by 10 ft.
Two 45° elbows will be treated like one 90° elbow.
For the side exhaust installations, add one 90° elbow to the chart.
The total vent system length includes all the straight portions and elbows of the system (transition
duct included).
Laundry Center length includes factory-installed elbow that does not impact vent length.
of 4" dia rigid
metal duct
Exhaust hood type
of 90°
turns
0 200 ft. 175 f t.
1 185 ft. 165 f t.
2 175 ft. 155 ft.
3 165 f t. 145 ft.
4 155 ft. 135 ft .
5 145 ft . 125 ft.
0 150 ft. 125 ft.
1 135 f t. 115 ft.
2 125 ft. 105 ft.
3 115 ft. 95 ft.
4 105 ft. 85 ft.
5 95 ft. 75 ft.
0 90 ft. 60 ft.
1 60 ft. 45 f t.
2 45 ft . 35 f t.
3 35 ft. 25 ft.
4 25 ft. 15 ft.
0 90 ft. 60 ft.
1 60 ft. 45 f t.
2 45 ft . 35 f t.
3 35 ft. 25 ft.
0 46 ft. 37 f t.
1 37 ft. 30 ft.
2 30 ft. 22 ft.
3 23 ft. 15 ft.
0 56 ft. 42 ft.
1 48 ft. 34 ft.
2 40 ft. 26 ft.
3 32 ft. 18 ft.
0 43 ft. 36 ft.
1 33 ft . 26 ft.
2 24 f t. 16 f t.
A
4"
opening
Specification Revised 3/14
B
2-1 /2"
opening
370132