[] Two Phillips head countertop mounting screws taped to dishwasher
Materials required:
[] 90° elbow
(3/8"NPT external thread on one end and opposite end sized to fit water supply)
[] Thread seal tape [] UL Listed Wire nuts (3)
Fornew installations only: [] Air gap for drain hose, if required [] Waste tee for house plumbing, if applicable
[] Electrical cable or power cord, ifapplicable [] Screwtype hose clamps
[] Strain relief for electrical connection [] Hand shut-off valve (recommended)
[] Water line 3/8"min. copper or 1/2"min. plastic [] Coupler for extending drain line, ifapplicable
Electrical Cable
or Power Cord
StrainRelief Tape
A,r Waste() )
Gap Tee
Installationofthisdishwasherrequiresbasicmechanicaland electricalskills.Properinstallation is the responsibilityof the
cover of the Owners Manual for warranty information. The dishwasher MUST beinstalledto allow for future removal from the enclosure if service isrequired.
Screw Type Clamps
HotWaterLine
ThreadSeal
Wire Nuts
Shut-Off
Valve
Coupler
Toolsrequired:
[] Phillips head and flat blade screwdrivers [] Adjustable wrench (6") [] Level
[] Carpenters square [] Measuring tape
[] Safety glasses [] Flashlight
Fornew installations only: [] Tubing cutter
[] Drill and appropriate bits [] Holesaw set
SafetyGlasses
FlatBlade Screwdriver
Adjustable
Wrench
Measuring Tape
Flashlight Hole
Saw Set
__Sc rePhillipsHead
wdri_
_Tubing // Drill
_Cutter _/ andBits _-_
Square
Level
The rough cabinet opening must have a minimum width and depth of 24",and approximately 34-1/2"high from floor to
underside of the countertop. Figure A
The backwall should be free of pipes or wires. Figure A
Adjacent cabinets should be square and plumbto ensure a good fit. Figure A
For corner installation, allow 2" min. clearance between dishwasher and adjacent cabinet or wall or other appliances. Figure B
This'v%ll Area
)[
Ppesorwires
34--1/2":_1/4" UndersideoF
Countertop
to%or
Countertop
E
Dishwasher _\l
25"
FigureB
Clearancefor Door Openi_g2" Min}mum
DRAIN REQUIREMENTS
Follow local codes and ordinances.
Dishwasher drain hose must not exceed 10feet in length for proper drainage.
Dishwasher must be connected to waste line with an air gap (not supplied) or 32" minimum, high drain loop depend-
ing on local codes and ordinances to prevent backflow into
the dishwasher.
Air gapmust be used if waste tee or disposer connection is less than 18inches above floor to prevent siphoning.
Cab}_etsSquae a_dPlumb
Make sure the floor is level inside the opening and even with the finished floor of the kitchen.
The dishwasher must be installed no more than 10feet from
sink for proper drainage.
This dishwasher must befully enclosed onthe top, sides
and back.
The dishwasher must not support any part of the enclosure.
METHOD1-Air Gapwith Waste Teeor Disposer
WasteTeeInstallation
FigureC
DisposerInstallation
DRAIN PREPARATION The type of drain installation depends onanswers to the
following questions: [] Do local codes or ordinances require an air gap?
[] Will waste tee or disposer connection be less than 18"
abovefloor?
[] Will installation have a drain loop lessthan 32"above floor?
If the answer to ANY of the 3 questions above is YES, Method
1 MUST be used. Otherwise either Method 1 or Method 2 may
be used. Figure C or Figure D.
An air gap MUST BE USEDif the drain hose is connected to waste tee or disposer lower than 18"above the floor level.
Failure to provide the proper drain connection height with air gap or 32"minimum, high drain loop will result in improper
dra n ng of the d shwasher wh ch may cause damage.
METHOD 2-High Drain with Waste Tee or Disposer Providea method to attach drain hose to underside of
countertop. Attachment will be made in a later step.
g:--
Waste Tee Installation Figure D
Install waste tee or disposer and air gap according to manufacturer's instructions.
CABINET PREPARATION Drill 1-1/2"inch diameter hole in the cabinet wall within the
shaded area shown in Figure A for the drain hose. Make sure there are no sharp edges. Drain hose will be passedthrough
this hole and connected to the drain in a later step.
DisposerInstallation
WARNING
FORPERSONALSAFETY:REMOVEHOUSE
FUSEOROPEN CIRCUITBREAKERBEFORE
BEGINNINGINSTALLATION. DONOTUSEAN EXTENSIONCORDDRADAPTER PLUG
WITH THIS APPLIANCE.
ELECTRICALREQUIREMENTS:
This appliance must be supplied with 120V,60 Hz.,and connected to an individual, properly grounded branch
circuit, protected by a 15or 20ampere circuit breaker or
time delay fuse.
Wiring must be 2wire with ground.
Ifthe electrical supply provided does not meet the
above requirements, call a licensed electrician before
proceeding.
GROUNDING INSTRUCTION
This appliance must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding conduc-
tor must be run with the circuit conductors and be connected to the equipment-grounding terminal orlead on the appliance.
-1-1/2"Dia.Flole(Max,)
FigureE
CABINET PREPARATION & WIRE ROUTING
Wiring may enter from either side, the rear, or from the floor within the shaded area shown in Figure E.
Cuthole 1-1/2"max. dia.within the shaded area to admit the
electrical cable or power cord. The hole must be free of sharp edges. If the cabinet wall partition is metal,the edge
ofthe hole must be covered with a rubber protector.
4"
Cabinet
Black_"
White
WARNING
THEIMPROPERCONNECTIONOFTHEEQUIPMENT-
GROUNDINGCONDUCTORCAN RESULTINA RISK
OFELECTRICSHOCK.CHECKWITH A QUALIFIEDELECTRICIAN ORSERVICEREPRESENTATIVEIFYOUAREINDOUBT
WHETHERTHEAPPLIANCEIS PROPERLYGROUNDED.
1.The hot water line may enter from either side, the rear or from the floor within the shaded area shown in Figure E
2.Cut a hole approximately 1-1/2"dia. within the shaded area to
admit the line.
3.Turn off the water supply.
4. Install a hand shut-off valve in the supply line in anaccessible location, such as under the sink. (The shut-off valve is optional, but recommended and may be required by local codes.)
5.Water connection is on left side of dishwasher. Install the hot water inlet line, using no less than 3/8" O.D.copper tubing or
1/2"O.D.plastic tubing. Route line as shown in Figure E Extend
the water line forward at least 19"from rear wall.
6.Adjust the water heater to deliver water between the temperatures of 120°Fand 150°E
7. Flushwater line to clean out debris.
8.The water pressure of the hot water supply line must be
20-120PSI.
ELECTRICALCONNECTIONS TO DISHWASHER
Electrical connection is on right side of dishwasher.
Forcable direct connections the cable must be routed as shown in Figure E.Cable must extend a minimum of 24"from
the rear wall.
Forpower cord connections, install a3-prong grounding
type receptacle in the rear wall of sink cabinet next to the
dishwasher. The receptacle should be installed at least
6", but not more than 18",from the cabinet opening for
dishwasher.
Cabinet Face
2" FromFloor
FigureF