215C1219P001 49-50234-3 02-09 JR
GNSV70RBL
GNSV75RWW
Owner’s Manual and
Installation Instructions
Safety Instructions
System Overview . . . . . . . . . . . . .3–5
Installation Instructions . . . .6–12
Battery Installation . . . . . . . . . . . . . . . .11
Faucet Installation . . . . . . . . . . . . . . . .7, 8
Feed Water Supply . . . . . . . . . . . . . . .6, 7
Filter Replacement . . . . . . . . . . . . . . . . .12
Flush Procedure . . . . . . . . . . . . . . . . . . .12
Installing the Tubing . . . . . . . . . . . . . . .11
System Installation . . . . . . . . . . . . . .9, 10
Troubleshooting Tips . . . . . . . . . .13

Consumer Support

Consumer Support . . . . . . . .Back Cover
Parts List/Catalog . . . . . . . . . . . . . . . . . .14
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . .15
GNSV70RBL and GNSV75RWW are Tested and Certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine: Taste and Odor and Particulate Class I and Standard 53 for the reduction of Lead, Cyst, Turbidity, Asbestos, Mercury, Lindane, Atrazine, Benzene and VOC.
2
IMPORTANT SAFETY INFORMATION.
WARNING:
Read entire manual. Failure to follow all guides and rules could cause personal injury or property
damage.
Check with your local public works department for plumbing codes. You must follow their guidelines as you install the Water Filtration system.
SAFETY PRECAUTIONS
Use the Water Filtration system on a potable, safe-to-drink, home COLD water supply only. The filter canisters will not purify the water, or make it safe to drink.
Do not use on a hot water supply (100°F max.). Install on a cold water line only.
WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
PROPER INSTALLATION
This Water Filtration system must be properly installed and located in accordance with the Installation Instructions before it is used.
CAUTION:To reduce the risk of property damage due to water leakage, install or store where it will not be exposed to
temperatures below freezing or exposed to any type of weather. Water freezing in the system may damage it and may result in water leakage, damaging property. Change the filter out if it was exposed to freezing temperatures. Do not attempt to treat water over 100°F.
WARNING: Discard all unused and packaging material after installation. Small parts remaining after installation could
be a choke hazard.
Your Water Filtration system will withstand up to 120 pounds per square inch (psi) water pressure. If your house water supply pressure is higher than 80 psi, install a pressure reducing valve before installing the Water Filtration system.
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
Specifications Guidelines.
The Water Filtration System Uses the Following Canisters
Models GNSV70RBL and GNSV75RWW
FQSVF Filter (160 gallon capacity) Filter—White canisters with green band
Reduces dirt, rust and sediment
Reduces Chlorine: Taste and Odor
Reduces Lead
Reduces filterable Cysts (such as cryptosporidium and giardia)
Reduces Turbidity
Reduces Asbestos
Reduces Mercury
Reduces Lindane
Reduces Atrazine
Reduces Benzene
Reduces VOC
0.5–1 micron nominal particulate reduction
This system conforms to NSF/ANSI 42 and 53 for the specific performance claims as verified and sustained by test data. See Performance Data Sheet for details.
Installation Overview
Locate the drinking water system on the cold water supply pipe, under the kitchen and/or bathroom sink, to filter the cold drinking water.
3
Sink
Water Supply Valve
Filtered Water Faucet
Inlet Outlet
Filter Canisters
Manifold
Hot Cold
Performance Data Sheet.
SmartWater Filtration System GNSV70RBL and GNSV75RWW Using Filter FQSVF
This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
Actual performance may vary with local water conditions.
WARNING:
Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection
before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
Standard No. 42: Aesthetic Effects
USEPA Influent Influent
Effluent % Reduction
Min. Required
Parameter MCL Challenge Concentration Average Average Maximum Average Minimum Reduction
Chlorine 2.0 mg/L + 10% 2.00 mg/L <0.05 mg/L <0.05 mg/L 97.50% 97.50% >50% T & O — Particulate** ≥ 10000 particles 4100000 #/mL 76500 #/mL 110000 #/mL 98.10% 97.30% >85%
Standard No. 53: Health Effects
Turbidity 0.5 NTU*** 11 + 1 NTU*** 11.0 NTU 0.1 NTU 0.1 NTU 98.80% 98.20% 0.5 NTU Cysts 99.95% red. Min. 50000L 140000 #/L 1 #/L 1 #/L >99.99% >99.99% 99.95% Asbestos 99% red. 280 MF/L <0.17 MF/L <0.17 MF/L >99.00% >99.00% 99% Lead, 0.010 mg/L 0.15 mg/L + 10% 0.150 mg/L <0.001 mg/L <0.001 mg/L >99.30% >99.30% 0.010 mg/L
pH 6.5 Lead, 0.010 mg/L 0.15 mg/L + 10% 0.140 mg/L <0.001 mg/L <0.001 mg/L >99.30% >99.30% 0.010 mg/L
pH 8.5 Mercury, 0.002 mg/L 0.006 mg/L ± 10% 0.0065 mg/L <0.0002 mg/L <0.0002 mg/L 96.60% >96.70% 0.002 mg/L
pH 6.5 Mercury, 0.002 mg/L 0.006 mg/L ± 10% 0.0059 mg/L <0.0002 mg/L <0.0002 mg/L 96.60% 96.70% 0.002 mg/L
pH 8.5 Lindane 0.0002 mg/L 0.002 mg/L ± 10% 0.00193 mg/L <0.00002 mg/L 0.00005 mg/L >98.80% 98.80% 0.0002 mg/L Benzene 0.001 mg/L 0.015 mg/L ± 10% 0.014 mg/L <0.0005 mg/L <0.0005 mg/L >96.40% >96.40% 0.005 mg/L Atrazine 0.003 mg/L 0.009 mg/L ± 10% 0.00873 mg/L <0.0005 mg/L <0.0005 mg/L >94.10% >94.10% 0.003 mg/L
VOC Reduction
Chloroform 0. 080 mg/L 0.300 ± 10% 0.340 mg/L 0.00098 mg/L 0.00620 mg/L 97.90% 98.20% 95% *Tested using a flow rate of 0.60 gpm (2.27 l/min); pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C) **Measurement in particles/mL. Particles used were 0.5–1 microns. ***NTU—Nephelometric Turbidity Units
Operating Specifications
Capacity: certified for up to 160 gallons (605 l); up to six months Pressure requirement: 35–120 psi (2.8–8.2 bar) Temperature: 33–100°F (0.6–38°C) Flow rate: 0.60 gpm (2.27 l/min)
4
Replacement Filter Canisters/Estimated Replacement Costs
FQSVF—Replacement filter canister $35–40 For replacement parts, call toll-free 800.626.2002 (U.S.), 800.663.6060 (Canada–English), 800.361.3869 (Canada–French)
IOWA RESIDENTS ONLY:
Store or Seller’s Name
Address
City State Zip Telephone
Seller’s signature
Customer’s signature Date
Maximum Permissible
Product Water Concentration
State of California
Department of Health Services
Water Treatment Device
Certificate Number
160104 -
Trademark/Model Designation
GXSV65 F FQSVF GQSV65 F FQSVF GNSV70 FBL FQSVF GNSV75 FWW FQSVF GXSV65 R FQSVF GNSV75 RWW FQSVF GNSV70 RBL FQSVF
Manufacturer: General Electric Company
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants:
Microbiological Contaminants and Turbidity
Cysts Turbidity
Organic Contaminants
Atrazine Lindane Benzene VOCs
Alachlor Atrazine Benzene Carbofuran Carbon Tetrachloride Chlorobenzene Chloropicrin 2,4-D DBCP o-Dichlorobenzene p-Dichlorobenzene 1,2-Dichloroethane 1,1-Dichloroethylene cis-1,2-Dichloroethylene trans-1,2-Dichloroethylene 1,2-Dichloropropane cis-1,3-Dichloropropylene Dinoseb
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
Date Issued: February 9, 2009
160 galRated Service Capacity: 0.6 gpm
Endrin Ethylbenzene EDB Haloacetonitriles (HAN)
Bromochloroacetonitrile Dibromoacetonitrile Dichloroacetonitrile Trichloroacetonitrile
Haloketones (HK)
1,1-Dichloro-2-Propanone
1,1,1-Trichloro-2-Propanone Heptachlor Heptachlor Epoxide Hexachlorobutadiene Hexachlorocyclopentadiene Lindane Methoxychlor Pentachlorophenol
Rated Service Flow:
Replacement Element(s)
Inorganic/Radiological Contaminants
Asbestos Lead Mercury
Simazine Styrene 1,1,2,2-Tetrachloroethane Tetrachloroethylene Toluene 2,4,5-TP (Silvex) Tribromoacetic Acid 1,2,4-Trichlorobenzene 1,1,1-Trichloroethane 1,1,2-Trichloroethane Trichloroethylene Trihalomethanes (THMs)
Bromodichloromethane Bromoform Chloroform Chlorodibromomethane
Xylenes
1
Influent challenge levels are average influent concentrations determined in surrogate qualification testing.
2
μg/L means Micrograms Per Liter.
3
Maximum product water level was not observed but was set at the detection limit of the analysis.
4
Maximum product level is set at a value determined in surrogate qualification testing.
5
Chemical reduction percent and maximum product water level calculated at chloroform 95% breakthrough point as determined in surrogate qualification testing.
6
The surrogate test results for heptachlor Epoxide demonstrated a 98% reduction. These data were used to calculate an upper occurrence concentration, which would produce a maximum product water level at the MCL.
Organic Chemicals Reduced by Chloroform Surrogate Testing
Avg.
1
Max.
Contaminant Influent (μg/L)
2
Effluent (μg/L)
2
Alachlor 50 1.0
3
Atrazine 100 3.0
3
Benzene 81 1.0
3
Carbofuran 190 1.0
3
Carbon Tetrachloride 78 1.8
4
Chlorobenzene 77 1.0
3
Chloropicrin 15 0.2
4
2,4-D 110 1.7
4
Dibromochloropropane (DBCP) 52 0.02
3
o-Dichlorobenzene 80 1.0
3
p-Dichlorobenzene 40 1.0
3
1,2-Dichloroethane 88 4.8
5
1,1-Dichloroethylene 83 1.0
3
cis-1,2-Dichloroethylene 170 0.5
3
trans-1,2-Dichloroethylene 86 1.0
3
1,2-Dichloropropane 80 1.0
3
cis-1,3-Dichloropropylene 79 1.0
3
Dinoseb 170 0.2
4
Endrin 53 0.59
4
Ethylbenzene 88 1.0
3
Ethylene Dibromide (EDB) 44 0.02
3
Haloacetonitriles (HAN):
Bromochloroacetonitrile 22 0.5
4
Dibromoacetonitrile 24 0.6
4
Dichloroacetonitrile 9.6 0.2
4
Trichloroacetonitrile 15 0.3
4
Testing was performed under standard laboratory conditions; actual performance may vary.
NOTE: Substances reduced are not necessarily in your water. Filter must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.
WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst
reduction may be used on disinfected waters that contain filterable cysts.
Performance Data Sheet.
5
Loading...
+ 11 hidden pages