GFDS260GF/265GF
GE® 8.1 cu. ft. capacity Front Load gas dryer with steam
Dimensions and Installation Information (in inches)
Gas Dryer Rating
120V
Exhaust Options: 3-way via rear, left, and bottom.
Circuit Requirements: An individual, properly grounded
branch circuit, protected by a 15-20 amp circuit breaker
or a time-delay fuse, is required.
Note: Dryer wall outlet must be located within 36”
of service cord entry and accessible when dryer is
mounted in position.
Installation Information: For complete information, see
installation instructions packed with your dryer.
60Hz, 8A, 850W
52"
25-3/8"
4-5/8"
2-1/4"
For answers to your Monogram,® Cafe™ Series
or Profile™ Series appliance questions, visit
our website at geappliances.com or call GE
Answer Center® service, 800.626.2000.
5-7/8
39-2/5
3-5/8
Specification Revised 3/14
360504
GFDS260GF/265GF
GE® 8.1 cu. ft. capacity Front Load gas dryer with steam
Special Installation Requirements:
Stacked Installation:
Brackets for stacking dryer over washer are not included
with the washer.
Order part no. GEFLSTACK or part no. WE25X10018.
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it
will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls
or other surfaces are: 0" either side, 3" front and rear
• Minimum vertical space from floor to overhead cabinets,
ceilings, etc. is 52".
• Closet doors must be louvered or otherwise ventilated and must
contain a minimum of 60 sq. in. of open area equally distributed.
If this closet contains both a washer and a dryer, doors
must contain a minimum of 120 sq. in. of open area equally
distributed.
• No other fuel-burning appliance shall be installed in the same
closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the
absence of local codes, with the National Electric Code and
National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearance other than Alcove or Closet Installations:
• Minimum clearances to combustible surfaces 0" both sides,
3" rear.
For more information on venting kits and accessories,
please call 1-800-GE-CARES.
5-3/8
1-5/8
11-5/8
Stacked Dimensions (in inches)
79-5/8
C
3-5/8
Pedestal Dimensions (in inches)
GFXP1308F
This optional 13" pedestal raises
the door opening and height of
the washer or dryer.
27-7/8
13
29-3/4
®
For answers to your Monogram,
or Profile™ Series appliance questions, visit
our website at geappliances.com or call GE
Answer Center® service, 800.626.2000.
Cafe™ Series
Specification Revised 3/14
360504