GE GFDS170EH0WW, GFDS170EH1WW, GFDS170EH2WW, GFDS170GH0WW, GFDS170GH1WW Installation Guide

...
0 (0)
Installati
Instructi
n
ns
Dryers
01
i Questions? Call800.GE.CARES {800.432.2737)orvisitour Web siteat:GEAppliances.com J
A
All safety messages will follow the safety alert symbol and the word "DANGER","WARNING", or "CAUTION".These
words are defined as:
Indicates a hazardoussituation which, if not avoided,will resultin death or seriousinJury.
Indicates a hazardoussituation which, if not avoided, could result indeath or seriousinJury.
Indicates a hazardoussituation which, if not avoided, could result inminor or moderate inJury.
BEFORE YOU BEGIN
Readthese instructions completely and carefully.
IMPORTANT- savetheseinstructionsforlocal
electrical inspector's use.
IMPORTANT- Observeallgoverning codesand
ordinances.
Installthe clothes dryer according to the manufacturer's
instructions and local codes.
Note to Installer - Be sure to leavethese instructions
with the Consumer.
Note to Consumer - Keepthese instructions for future
reference.
Clothes dryer installation must be performed by a
qualified installer.
Thisdryer must be exhausted to the outdoors.
Before the old dryer is removed from service or
discarded, remove the dryer door.
Service information and the wiring diagram are located
in the control console.
Do not allow children on or inthe appliance. Close
supervision of children isnecessary when the appliance
is used near children.
Proper installation isthe responsibility of the installer.
Product failure due to improper installation is not
covered under the Warranty.
Install the dryer where the temperature is above 50°F
for satisfactory operation of the dryer control system.
Remove and discard existing plastic or metal foil duct
and replace with U/_-Iistedduct.
Printed in Mexico
- Fire Hazard
Clothes dryer installation must be performed by a
qualified installer.
Install the clothes dryer according to these
instructions and local codes.
DO NOT install a clothes dryer with flexible plastic
venting materials. If flexible metal (semi-rigid or
foil-type) duct is installed, it must be UL-listed and
installed in accordance with the instructions found
in "Connecting the Dryer to House Vent" later in
this manual. Flexible vent materials are known to
collapse, be easily crushed and trap lint. These
conditions will obstruct dryer airflow and increase
the risk of fire.
DO NOT install or store this appliance in any
location where it could be exposed to water or
weather.
To reduce the risk of severe inJuryor death, follow
all installation instructions.
Save these instructions. (Installers: Be sure to leave
these instructions with the customer.)
IIIIIII11111111IIIIIIIIIIIIIIIIIIIIIIIII
234D2274P001
31-16748 o4-14 GE
Installation Instructions
UNPACKING YOUR DRYER
Tilt the dryer sideways and remove the foam
shipping pads by pulling at the sides and breaking
them away from the dryer legs. Be sure to remove all
of the foam pieces around the legs.
Remove the bag containing the literature.
q
ROUGH-IN
DIMENSIONS
Front View
27"
(68.6cm)
©
NOTE:
Dryer height can be adjusted to match washer height
With Pedestal: 52.1" (152.55 cm)
Stacked: 84" (215.56 cm)
39.3"
(99.8cm)
I 33" (83.8 cm)
39.3"
(99.8 cm)
Side View
I 4.4"
(11.2 cm)
STEAM WATER HOSES:
GEstrongly recommends the useof factory specified parts.
Thesehosesare manufactured andtested to meet GE
specifications.
GEstrongly recommends the useof new water supply hoses.
Hosesdegrade overtime and need to bereplaced every 5
years to reducethe risk of hose failures and water damage.
Parts and Accessories
Order on-line at GEAppliencePorts.com, 24 hours a day or
by phone at 800.626.2002during normal businesshours.
Part Number
WE25iv153
OR
WE1M847
WEliVt848
plvl14X10056
WX14X10007
Accessory
CompleteKit(hoses,Y-adapter
washers)(included)
LongHoseand
ShortHose
Dryerdooropeningventbrush
(notincluded)
LintEaterTM Dryerrotarytube brush
(notincluded)
POWER CORDS:
GEstrongly recommends the useof factory specified parts.
Selectthe power cord to fit your installation requirements.
Order on-line at GEApplianceParts.com, 24 hours a day or
by phone at 800.626.2002during normal businesshours.
Part Number Type Length Amperage
WX9X2 3-Prong . 4 Feet . 30
WX9X3 3-Prong 5 Feet 30
WX9X4 3-Prong 6 Feet 30
WX9X18 4-Prong 4 Feet 30
WX9X19 4-Prong 5 Feet 30
WX9X20 4-Prong 6 Feet 30
Installation Instructions
REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
_- Explosion Hazard
Keepflammable materials and vapors, such as gasoline,
away from dryer.
Placedryer at least Z8"(46 cm) above the floor for a
garage installation.
Failureto do so can result in death, explosion, or fire.
, If the dryer is approved for installation in an
alcove or closet, it will be stated on a label on the
dryer back.
, The dryer MUST be vented to the outdoors. See
the EXHAUSTING THE DRYERsection.
, Minimum clearance between dryer cabinet and
adjacent walls or other surfaces is:
0" either side
3" front
3" rear
52" from floor to overhead cabinets
, Consideration must be given to provide adequate
clearance for installation and service.
, Closet ventilation openings required: 2 louvers
each 60 square inches (387 square cm), located 3
inches (7.6 cm) from top and bottom of door.
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT
THE REAR OF THE DRYER, MINIMUM CLEARANCE
FROM THE WALL iS 5.5 in.
Gas Dryers Only:
, No other fuel burning appliance shall be installed
in the same closet as a gas dryer.
, The dryer must be disconnected from the gas
supply piping during pressure testing at pressures
greater than 1,_psi (3.5 kPa).
, A 1/8 inch NPT minimum plugged tapping,
accessible for test gauge connection, must be
installed immediately upstream of the gas supply
connection to the dryer.
MINIMUM CLEARANCE OTHER THAN
ALCOVE OR CLOSET INSTALLATION
Minimum clearance to combustible surfaces and
for air opening are: O" both sides, 1" front, 3" rear
and 1" top. Consideration must be given to provide
adequate clearance for installation and service.
MOBILE OR MANUFACTURED HOME
INSTALLATION
, Installation must conform to the
MANUFACTURED HOME CONSTRUCTION AND
SAFETYSTANDARD, TITLE 24, PART32-80 or
Standard CAN/CSA-Z240 MH, or, when such
standard is not applicable, with AMERICAN
NATIONAL STANDARD FOR MOBILE HOME,
ANSI/NFPA NO. 50lB.
, The dryer MUST be vented to the outdoors. The
exhaust vent must be securely fastened to a
non-combustible portion of the mobile home.
, The vent MUST NOT be terminated beneath a
mobile or manufactured home.
, The vent duct material MUST BE METAL.
, KIT 14-D346-33 MUST be used to attach the dryer
securely to the structure.
, The vent MUST NOT be connected to any other
duct, vent or chimney.
, Do not use sheet metal screws or other
fastening devices which extend into the interior
of the exhaust vent.
, Provide an opening with a free area of at least
25 square inches for introduction of outside air
into the dryer room.
, See the sections for electrical connection
information.
Installation Instructions
CONNECTING INLET HOSES
CONNECTING iNLET HOSES
To produce steam, the dryer must connect to
the cold water supply. Since the washer must
also connect to the cold water, a "Y" connector
is inserted to allow both inlet hoses to make that
connection at the same time.
NOTE: Use the new inlet hoses provided; never use
old hoses.
. Turn the cold water faucet off. Remove the
washer inlet hose from the washer fill valve
connector (cold).
2. Ensure the rubber flat washer is in place and
screw the female coupling of the short hose
onto the washer fill valve connector. Tighten by
hand until firmly seated.
3. Attach the female end of the "Y" connector to
the male coupling of the short hose. Ensure the
rubber flat washer is in place. Tighten by hand
until firmly seated.
4. Insert the filter screen in the coupling of the
washer's inlet hose. If a rubber flat washer is
already in place remove it before installing the
filter screen. Attach this coupling to one male
end of the "Y" connector. Tighten by hand until
firmly seated.
5. Ensure the rubber flat washer is in place and
attach the dryer's long inlet hose to the other
male end of the "Y" connector. Tighten by hand
until firmly seated.
.
Ensure the rubber flat washer is in place and
attach the other end of the dryer's long inlet
hose to the fill valve connector at the bottom
of the dryer back panel. Tighten by hand until
firmly seated.
CONNECTING INLET HOSES (cont.)
7. Using pliers, tighten all the couplings with an
additional two-thirds turn.
NOTE: Do not overtighten. Damage to the couplings
may result.
8, Turn the water faucet on.
9. Check for leaks around the "Y" connector, faucet
and hose couplings.
WATER SUPPLY REgUIREIENTS
Hot and cold water faucets MUST be installed
within 42 in. (107 cm) of your washer's water
inlet. The faucets MUST be 3/4 in. (1.9 cm) garden
hose-type so inlet hoses can be connected. Water
pressure MUST be between 10 and 120 pounds
per square inch. Your water department can
advise you of your water pressure.
NOTE: A water softener is recommended to reduce
buildup of scale inside the steam generator if the
home water supply is very hard.
Installation Instructions
CONNECTING A GAS
TOOLS YOU WILL NEED
DRYER(ski
17lO" Adjustable
wrenches (2)
178" Pipe wrench
0 Flat-blade
screwdriver
13Level
17Slip-joint pliers
MATERIALS YOU WILL NEED
04" dia. metal elbow
17Pipe compound or
PTFEtape
17Flexible gas line
connector
%
174" dia., UL-listed
flexible metal duct (if
needed)
17Gloves
0
C1Soap solution for
leak detection
17Duct clamps (2) or
Spring clamps (2)
1:3Safety glasses
}
04" dia. metal duct
(recommended)
13Exhaust hood
17Duct tape
OGas pipe adapters (2),
elbow and pipe plug
) for electric dryers)
Before beginning the installation, turn off
the circuit breaker(s) or remove the dryer's circuit
fuse(s) at the electrical box. Be sure the dryer cord
is unplugged from the wall.
Turn the dryer's gas shut-off valve in the supply
line to the OFF position.
Shut-off
Valve
Disconnect and discard old flexible gas connector
and ducting material.
Installation Instructions
CONNECTING A GAS DRYER (cant,)
GAS REQUIREMENTS
o
o
o
_'- Explosion Hazard
Use a new CSAInternational approved flexible
gas supply line. Never reuse old flexible
connectors.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LPgas, have a qualified person
make sure gas pressure does not exceed 13"
water column.
. Examples of a qualified person include: licensed
heating personnel, authorized gas company
personnel, and authorized service personnel.
. Failure to do so can result in death, explosion,
or fire.
This gas dryer is equipped with a Valve & Burner
Assembly for use only with natural gas, Using
conversion kit WE25X0217, your local service
organization can convert this dryer for use with
propane (LP)gas. ALL CONVERSIONS MUST BE
MADE BY PROPERLYTRAINED AND QUALIFIED
PERSONNELAND IN ACCORDANCE WITH LOCAL
CODES AND ORDINANCE REQUIREMENTS.
DRYER GAS SUPPLY CONNECTION
2 !!
t5/8"
"- 3/8" NPT MALETHREAD GAS SUPPLY
NOTE:Add to vertical dimension
the distance between cabinet
bottom to floor.
. You must use with this dryer a flexible metal
connector (listed connector ANSI Z21.24/CSA 6.10).
The length of the connect shall not exceed 3 ft.
GAS SUPPLY
, A 1/8" National Pipe Taper thread plugged
tapping, accessible for test gauge connection,
must be installed immediately upstream of the
gas supply connection to the dryer. Contact
your local gas utility should you have questions
on the installation of the plugged tapping.
, Supply line is to be 1/2" rigid pipe and equipped
with an accessible shutoff within 6 feet of, and
in the same room with, the dryer.
, Use pipe thread compound appropriate for
natural or LP gas or use PTFEtape.
, Connect flexible metal connector to dryer and
gas supply.
, The installation must conform with local codes,
or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54,
or the Natural Gas and Propane Installation
Code, CSA B149.1.
IN THE COMMONWEALTH OF
MASSACHUSETTS
,, This product must be installed by a licensed
plumber or gas fitter.
. When using ball-type gas shut-off valves, they
shall be the T-handle type.
. A flexible gas connector, when used, must not
exceed 3 feet.
ADJUSTING FOR ELEVATION
Gas clothes dryers input ratings are based on
sea level operation and need not be adjusted
for operation at or below 2000 ft. elevation. For
operation at elevations above 2000 ft., input
ratings should be reduced at a rate of 4 percent
for each 1000 ft. above sea level.
Installation must conform to local codes and
ordinances or, in their absence, the NATIONAL
FUEL GAS CODE, ANSI Z223.
Installation Instructions
CONNECTING THE DRYER TO THE GAS
SUPPLY
@
Install a female 3/8" NPT elbow at the end of the
dryer gas inlet.
Install a 3/8" flare union adapter to the female
elbow.
IMPORTANT: Use a pipe wrench to securely hold
on to the end of the dryer gas inlet to prevent
twisting the inlet.
NOTE: Apply pipe compound or PTFEtape to the
threads of the adapter and dryer gas inlet.
New Metal--_ /
Flexible Gas
Line Connector _g'_@Q
Adapter _ _i
Elbowj
Items not supplied
j Adapter
1/8" NPT
Pipe Plug for
J Checking Gas
Inlet Pressure
l_kl- Shut-Off Valve
-,_--- Pipe size at
least 1/2"
r_ Attach the flexible metal gas line connector to
the adapter.
Apply pipe compound to the
adapter and dryer gas inlet.
r_ Tighten the flexible gas line connection, using
two adjustable wrenches.
CONNECTING THE DRYERTO THE GAS
SUPPLYIcont.}
@Install a 1/8" NPT plugged topping to the dryer
gas line shut-off valve for checking gas inlet
pressure.
Install a flare union adapter to the plugged
topping.
NOTE: Apply pipe compound or PTFEtope
to the threads of the adapter and plugged
topping.
oArPPITYFPitPe;°tm Pa_und_0
male threads. __ W PlaUp_1_dg
r_ Tighten all connections, using two adjustable
wrenches. Do not overtighten.
EF1Open the gas shut-off valve.
Installation Instructions
CONNECTING A GAS DRYER (cont.)
TEST FOR LEAKS
Never use an open flame to test for gas leaks.
Check all connections for leaks with soapy solution
or equivalent.
Apply a soap solution. The leak test solution must
not contain ammonia, which could cause damage
to the brass fittings.
If leaks are found, close the valve, retighten the
joint and repeat the soap test.
Open Gos
ELECTRICAL CONNECTION
INFORMATION FOR GAS DRYERS
_,dL
_ - Electrical Shock Hazard
i
Plug into a grounded 3 prong outlet.
DO NOT remove ground prong.
DO NOT use an adapter.
DO NOT use an extension cord.
Failure to do so can result in death, fire or electrical
shock.
ELECTRICAL CONNECTION
INFORMATION FOR GAS DRYERS (cont.}
The dryer must be electrically grounded in
accordance with local codes, or in the absence of
local codes, with the National Electrical Code, ANSI/
NFPA 70 or Canadian Electrical Code, CSA C22.1
This appliance must be supplied with 120V, 60Hz,
and be connected to a properly grounded branch
circuit protected by a 15 or 20 amp circuit breaker
or time delay fuse. If electrical supply provided
does not meet these requirements, it is the owner's
responsibility to have a licensed electrician install a
properly grounded 3-prong outlet.
Ensure proper
ground exists
before use.
If local codes permit an external ground wire
(not provided) may be added by attaching to the
green ground screw on the rear of the dryer, and
to a grounded metal cold water pipe or other
established ground.
Ground
Screw
Installation Instructions
CONNECTING AN ELECTRIC DRYER
(Skip for gos dryers ond if your dryer olreody hos o power cord ottoched)
TOOLS YOU WILL NEED
C1Slip-joint pliers 17Phillips screwdriver
17Flat-blade crewdriver 17Level
MATERIALS YOU WILL NEED
174" dia. metal elbow
173/4" strain relief
IUL recognized)
04" duct
clamps (2)or
4" spring clamps (2)
0 Safety glasses
)
04" dia. metal duct
(recommended)
174" dia., UL-listed
flexible metal duct (if
needed)
17Gloves
0 Exhaust hood
17Duct tape
17Dryer power cord kit
(not provided with
dryer)
UL rated 120/240V,
30A with 3 or 4 prongs.
Identify the plug type
as per the house
receptacle before
purchasing line cord.
(5
174" Cover Plate (Kit
WE1H454)
Before making the electrical connection, turn off
the circuit breaker(s) or remove the dryer's circuit
fuse(s) at the electrical box. Be sure the dryer cord
is unplugged from the wall. NEVER LEAVE THE
ACCESS COVER OFF THE TERMINAL BLOCK.
CONNECTING AN
Installation Instructions
ELECTRICDRYER{cont.}
ELECTRICAL CONNECTION
INFORMATION FOR ELECTRIC DRYERS
For electrical connections using a
power cord:
- Fire Hazard
Use a new UL-listed 240V 30 amp dryer power supply
cord with closed ring terminals or spade terminals with
upturned ends.
Use a UL-listed strain relief.
Disconnect power before making electrical
connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining two supply wires to remaining two
terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical
shock.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected dryer: This dryer
must be grounded. In the event of a malfunction
or breakdown, grounding will reduce the risk
of electric shock by providing a path of least
resistance for electric current. This dryer uses a
cord having an equipment-grounding conductor
and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed
and grounded in accordance with all local codes
and ordinances.
Improper connection of the
equipment-grounding conductor
can result in a risk of electrical shock. Check with a
qualified electrician, or service representative or
personnel, if you are in doubt as to whether the
appliance is properly grounded. DO NOT modify the
plug on the power supply cord. If it will not fit the
outlet, have a proper outlet installed by a qualified
electrician.
SAVE THESE INSTRUCTIONS
ELECTRICAL CONNECTION
INFORMATION FOR ELECTRIC DRYERS
For direct wire connections:
- Fire Hazard
Use 10 gauge copper wire.
Use a UL-listed strain relief.
Disconnect power before making electrical
connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining two supply wires to remaining two
terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical
shock.
GROUNDING INSTRUCTIONS
For a permanently connected dryer: This
dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-
grounding conductor must be run with the circuit
conductors and connected to the equipment-
grounding terminal on the appliance.
Improper connection of the
equipment-grounding conductor
can result in a risk of electrical shock. Check with a
qualified electrician, or service representative or
personnel, if you are in doubt as to whether the
appliance is properly grounded.
SAVETHESEINSTRUCTIONS
10
Loading...
+ 22 hidden pages