GFDS150GD
GE® 7.5 cu. ft. capacity frontload gas dryer with Steam and stainless steel drum
Dimensions and Installation Information (in inches)
Gas Dryer Rating
120V
Exhaust Options: 3-way via rear, left, and bottom.
Circuit Requirements: An individual, properly grounded
branch circuit, protected by a 15-20 amp circuit breaker
or a time-delay fuse, is required.
Note: Dryer wall outlet must be located within 36”
of service cord entry and accessible when dryer is
mounted in position.
Installation Information: For complete information, see
installation instructions packed with your dryer.
60Hz, 6A
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
geappliances.com or call GE Answer Center®
service, 800.626.2000.
Specification Revised 9/12
360495
GFDS150GD
GE® 7.5 cu. ft. capacity frontload gas dryer with Steam and stainless steel drum
Special Installation Requirements:
Stacked Installation:
Brackets for stacking dryer over washer are not included with the washer.
Order part no. GEFLSTACK or part no. WE25X10018.
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be
stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other
surfaces are: 0" either side, 3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
• Closet doors must be louvered or otherwise ventilated and must contain a
minimum of 60 sq. in. of open area equally distributed. If this closet contains
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of
open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with
a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of
local codes, with the National Electric Code and National Fuel Gas Code,
ANSI Z223 for gas dryers.
Minimum Clearance other than Alcove or Closet Installations:
• Minimum clearances to combustible surfaces 0" both sides, 3" rear.
For more information on venting kits and accessories,
please call 1-800-GE-CARES.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
geappliances.com or call GE Answer Center®
service, 800.626.2000.
Stacked Dimensions (in inches)
24
3-1/4
Pedestal Dimensions (in inches)
SBSD137HWW - white
This optional 13" pedestal raises
the door opening and height of
the washer or dryer. Feet on 13"
pedestal allow it to adjust to
13-3/8" height.
1/2
27
13
28-3/4
Specification Revised 9/12