GFDR480GF/485GF
GE® 8.3 cu. ft. capacity RightHeight™ Design Front Load gas dryer with steam
Dimensions and Installation Information (in inches)
Gas Dryer Rating
120V
Exhaust Options: 2-way via rear and left.
Circuit Requirements: An individual, properly grounded
branch circuit, protected by a 15-20 amp circuit breaker
or a time-delay fuse, is required.
Note: Dryer wall outlet must be located within 36”
of service cord entry and accessible when dryer is
mounted in position.
Installation Information: For complete information, see
installation instructions packed with your dryer.
60Hz, 8A, 850W
47
7-3/4
3/4
28
24-3/8
25-7/8
27-7/8
34-3/8
23-1/8
24-3/8
28-1/2
34-1/8
34-1/2
2-1/4
For answers to your Monogram,® Cafe™ Series
or Profile™ Series appliance questions, visit
our website at geappliances.com or call GE
Answer Center® service, 800.626.2000.
Specification Revised 7/14
GFDR480GF/485GF
GE® 8.3 cu. ft. capacity RightHeight™ Design Front Load gas dryer with steam
Special Installation Requirements:
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be
stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other
surfaces are: 0" either side, 3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
• Closet doors must be louvered or otherwise ventilated and must contain a
minimum of 60 sq. in. of open area equally distributed. If this closet contains
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of
open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with
a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of
local codes, with the National Electric Code and National Fuel Gas Code,
ANSI Z223 for gas dryers.
Minimum Clearance other than Alcove or Closet Installations:
• Minimum clearances to combustible surfaces 0" both sides, 3" rear.
For more information on venting kits and accessories,
please call 1-800-GE-CARES.
5-3/8
1-5/8
11-5/8
52"
25-3/8"
4-5/8"
3-5/8
For answers to your Monogram,® Cafe™ Series
or Profile™ Series appliance questions, visit
our website at geappliances.com or call GE
Answer Center® service, 800.626.2000.
2-1/4"
Specification Revised 7/14