GE AIR F24, GE AIR F34, GE AIR F41 Service Manual

1
GE Consumer & Industrial Appliances
Split System Air Conditioner
Model numbers:
GE AIR F24 GE AIR F34 GE AIR F41
2
3
4
IInnttrroodduuccttiioonn aanndd FFeeaattuurrees
s
MMooddeell RReemmaarrkkss
GE AIR F24 1PH 230V 50Hz R407C
5
MMooddeell
RReemmaarrkkss
GE AIR F34
3PH 400V 50Hz R407C
6
MMooddeell
RReemmaarrkkss
GE AIR F41
3PH 400V 50Hz R407C
7
Model GE AIR F24 Function Cooling Heating Power (Phase-Frequency-Voltage) 1Ph 50Hz 230V Tot a l C a pa c i t y (W) 7000 8500 Rated power (W) 3000 3050 Rated current (A) 14.6 15.1 Air flow volume (m3/h) 1170 Dehumidify volume (L/h) 2.3 C.O.P/EER (W/W) 2.3 2.79
Model GE AIR F24 IN Fan motor speed (r/min) (H/M/L) 1360/1280/1240 Output power of motor(W) 100 Fan type-piece Centrifugal Fan-4 Diameter-length (mm) ф125×134 Evaporator Aluminum fin-copper tube Pipe diameter ф7
Row-fin distance (mm) 3-1.6
Extended area of heat exchange (I×H×L) 1.042×0.19 Swing motor model MP35CA Power of motor (W) 4
Fuse (A) PCB5A Transformer 0.2A
Sound (pressure level) dB(A) ≤47 Dimension (W/D/H) (mm) 1300×188×600 Dimension of package (W/D/H) (mm) 1414×248×724
Indoor unit
Net weight/gross weight (kg) 32/36 Model GE AIR F24 OUT Input Power 2900 2950 Running Current 14.2 14.7 Compressor Model C-RN220H5B
Compressor Type Rotary Type
LRA(A) 75 Compressor Overload Protector Type Internal Inherent Protector Throttle Method Capillary Starting Method Capacitor
Range of working temperature( )℃ 7≤T≤43℃℃
Condenser Aluminum fin-copper tube Pipe diameter ф9.52 Row-fin distance (mm) 2-1.8 Extended area of heat exchange (I×H×L)mm
725×813
Fan motor speed (rpm) 60/780 Fan type-piece Axial Flow Fan-1 Fan Diameter (mm) Ф450
Defrosting Method Auto
Sound (pressure level) dB(A) ≤58 Dimension (W/D/H) (mm) 950×412×840 Dimension of package (W/D/H) (mm) 1100×450×920 Net weight/gross weight (kg) 75/87
Outdoor Unit
Refrigerant/Refrigerant Charge (kg) R407C/2.5 Length 5
Liquid Pipe (mm) Ф9.52(3/8”) Outer
Diameter
Gas Pipe (mm) Ф 16(5/8”) Height (m) 5
Connecting
Pipe
Max. Distance
Length (m) 10
8
Model GE AIR F34 GE AIR F41 Function Cooling Heating Cooling Heating Power (Phase-Frequency-Voltage) 3Ph - 400V - 50Hz 3Ph - 400V - 50Hz Tot a l C a pa c i t y (W) 10000 11500 12000 13000 Rated power (W) 4400 4400 5000 4600 Rated current (A) 7.5 7.5 8.3 7.8 Air flow volume (m3/h) 2100 2200 Dehumidify volume (L/h) 2.6 3.4 C.O.P/EER (W/W) 2.27 2.61 2.4 2.83
Model GE AIR F34 IN GE AIR F41 IN Fan motor speed (r/min) (H/M/L) 1140/1070/980 1110/1000/900 Output power of motor(W) 150 150 Fan type-piece Centrifugal Fan-4 Centrifugal Fan-4 Diameter-length (mm) ф145×175 ф155×175 Evaporator Aluminum fin-copper tube Aluminum fin-copper tube Pipe diameter ф7 ф7
Row-fin distance (mm) 3-1.6 3-1.6
Extended area of heat exchange (I×H×L)
1.34×0.25 1.34×0.25
Swing motor model MP35CA MP35CA Power of motor (W) 4 4 Fuse (A) PCB5A Transformer 0.2A PCB5A Transformer 0.2A Sound (pressure level) dB(A) ≤52 ≤55 Dimension (W/D/H) (mm) 1590×238×695 1590×238×695 Dimension of package (W/D/H) (mm) 1770×330×830 1714×330×830
Indoor unit
Net weight/gross weight (kg) 42/53 42/51 Model GE AIR F34 OUT GE AIR F41 OUT Compressor Model C-SBN303H8A C-SBN353H8A Input Power 4250 4250 4850 4450 Running Current 6.9 7 7.6 7.1
Compressor Type Rotary Type Rotary Type
LRA(A) 42 55 Compressor Overload Protector Type Internal Inherent Protector Internal Inherent Protector Throttle Method Capillary Capillary Starting Method Capacitor Capacitor
Range of working temperature( )℃ 2≤T≤43℃℃ 2≤T≤43℃℃
Condenser Aluminum fin-copper tube Aluminum fin-copper tube Pipe diameter ф9.52 ф9.52 Row-fin distance (mm) 2-1.4 2-1.8 Working Area mm2 813×930 725×1218 Fan motor speed (rpm) 920 840 Fan type-piece Axial Flow Fan-1 Axial Flow Fan-2 Fan Diameter (mm) Ф482 Ф450
Defrosting Method Auto Auto
Sound (pressure level) dB(A) ≤62 ≤63 Dimension (W/D/H) (mm) 1040×410×840 1250×950×412 Dimension of package (W/D/H) (mm) 1100×450×880 1295×1110×450 Net weight/gross weight (kg) 90/105 112/133
Outdoor Unit
Refrigerant/Refrigerant Charge (kg) R407C/3.1 R407C/3.4 Length 5 5
Liquid Pipe (mm) Ф12(1/2”) Ф12(1/2”) Outer
Diameter
Gas Pipe (mm) ф19(3/4”) ф19(3/4”) Height (m) 5 5
Connecting
Pipe
Max. Distance
Length (m) 10 10
9
CCoommppoonneenntt NNaammee
Applicable to GE AIR F24/ GE AIR F34
Indoor unit Swing Assy.
Air outlet
Decorative panel
Air inlet Water outlet
Front grill
Remote controller
Outdoor Unit
Air outlet
Connecting pipe
Air outlet grill
Drainage pipe
Air outlet
10
Applicable to GE AIR F41
Indoor unit
Swing Assy. Air outlet
Decorative panel
Air inlet Water outlet
Front grill
Remote controller
Outdoor Unit
Air outlet grill
Air outlet
Connecting pipe
Air outlet grill
Air outlet
Drainage pipe
11
OOvveerraallll aanndd IInnssttaalllliinngg DDiimmeennssiioon
n
Overall and Installing Dimension of Indoor Unit
Applicable to GE AIR F24 IN
Overall dimension
Installing dimension
12
Applicable to GE AIR F34 IN/ GE AIR F41 IN
13
Overall and Installing Dimension of Outdoor Unit
Applicable to GE AIR F24 OUT/ GE AIR F34 OUT
Unit: mm
Bolt Nut
Wrench
14
Applicable to GE AIR F41 OUT
Unit: mm
Bolt Nut
Wrench
15
SSyysstteemm DDiiaaggrraamm
System Diagram for Cooling-and-Heating Unit
Capillary
4-way valve
Evaporator Condenser
Gas-liquid
Cooling separator Compressor Heating
Switch on the power to start the unit. Low-pressure refrigerant vapor from evaporator is absorbed into the compressor, where it is compressed into high-temp. and high-pressure gas. The gas refrigerant is then diverted to condenser, where it is liquidized after heat exchange with outdoor air. After that, the liquidized refrigerant flows through capillary for decrease of temperature and pressure and then enters into evaporator, where it becomes low-temp. and low-pressure refrigerant vapor after heat exchange with indoor air to be regulated. This process is repeated in cycle to achieve the purpose of cooling. (Under heating mode, the 4-way valve will change the flow of refrigerant, so that the condenser absorbs heats and the evaporator gives out heats, thus to achieve the purpose of heating).
Loading...