GE EFNA Installation Guide

GE
Lighting
Evolve
(EFNA)
BEFORE YOU BEGIN
Read these instructions completely and carefully. Save these instructions for future use.
Risk of electrical shock. Disconnect power before servicing or installing product.
Risk of injury or damage. Unit will fall if not installed properly. Follow installation instructions.
Risk of fire. Use supply wire specied on nameplate.
LED Flood Light
WARNING
WARNING
WARNING
Installation Guide
GEH-6033
Not
e: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
CAUTION
Risk of injury. Wear safety glasses and gloves during
installation and servicing.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-003. This Class [A] RFLD complies with the Canadian standard NMB-003
imagination at work
applications, and should not be used in areas of limited ventilation, or in high ambient temperature enclosures.
• Best results will be obtained if installed and maintained according to the recommendations that follow.
• This luminaire is designed to operate in ambient temperatures ranging from -40°C to 50°C. This ood light is provided with either trunnion mounting, or pipe mounting.
SPECIFICATIONS
• Weight: 20.5 lbs. (9.3 kg)
• EPA: Horizontal Mounting: 0.56 sq. ft. max (0.05 sq M)
• IP rating: Optical 66, Standard Electrical Enclosure: UL 1598 Wet Location Rated.
UNPACKING
1
• This luminaire has been properly packed so that no parts should have been damaged during transit.
• Inspect to conrm.
HANDLING
2
• Damage may occur if luminaire is improperly handled outside of pack.
• Do not impact or stack luminaire after removal from packaging.
MOUNTING
3
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Follow installation instructions.
Follow Installation Instructions
1. Pipe Mounted Units:
on 1-7/8-inch O.D. through 2-3/8-inch O.D. or 2-7/8 O.D. through 3-inch O.D. pipes. Set screws are used to clamp the oodlight security to the pipe. Tighten set screws to 15 foot-pounds (20.3 N•m). Sliptter is designed to mount on a vertical pipe pointed upward such that gravity acts to hold oodlight in place while the set screws are tightened. Do not mount unit up-side-down.
The sliptter can be mounted
2.875 in.
4 Holes
FIGURE 2
• Open Wiring compartment cover located on the mounting bracket. Make electrical connections and close wiring compartment cover. Seal wall mounting ange to the mounting surface with silicone, caulk, or equivalent.
.4387 in.
4.375 in.
3. Trunnion Mounted Units: Mount directly on a
at surface. The Trunnion bracket has a clearance hole for a 3/4-inch bolt used for attachment. Tighten side trunnion bolts to 15-20 foot pounds.
• Connect xture supply leads inside of customer supplied junction box.
Note: Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements.
AIMING
3
1. Downward Aiming: On any orientations where
the glass is facing downward, remove the two power door drain hole screws.
Set Screws
FIGURE 1
• Open wiring compartment cover located on the mounting bracket. Make electrical connections and close wiring compartment cover.
Note: Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements.
2. Wall Mounted Units: The wall mounting plate
is provided with four .438-inch clearance holes spaced
4.375(H) x 2.875(V) inches for mounting. Do no mount the unit such that the hinge side of door is higher than
the latch side of door.
IMPORTANT: make sure all four rear drain holes are in place on downward orientations
Remove Drain Screw for downward position
Drain Screw remain for downward position
FIGURE 3
2. Vertical Aiming
When glass is in vertical orientation remove two drain screws from adapter as shown in Figure 4
IMPORTANT: make sure both power door drain screws and all four rear drain hole screws are in
place in the vertical orientation.
Drain Screws remain for forward position
Remove Drain Screw for upward position
FIGURE 6
External Dimming Control (If Applicable):
• Gray Lead = 0VDC (-)
• Violet Lead = Up To 10VDC (+)
Remove Drain Screw for forward position
Drain Screws remain for forward position
FIGURE 4
3. Upward Aiming
When the glass is facing upward, remove the four rear drain hole screws.
IMPORTANT: make sure both power door drain screws are in place on upward orientations
Dimming Input/Output Control Voltage1 Low (0-1.25V) H igh( 7.5 -10V ) Nominal Input Wattage2
Nominal Lumen Output
10% of Max 100%
2
• 1 Linear Transition between Low and High
• 2 Component and system tolerance may affect the
end point levels and linearity of transition
PE
Dimming Control (If Applicable):
• No external connections for Dimming are required when the GE Dimming PE Control and GE Dimming
PE Receptacle is used.
• All dimming control connections will be made between the Dimming PE and Luminaire through the
included PE Receptacle.
• Refer to instructions included with GE Dimming PE Control regarding appropriate settings for dimming
control.
Drain Screw remain for upward position
FIGURE 5
MAINTENANCE / CLEANING
5
WARNING
Risk of electric shock. Make certain power is off before
attempting any maintenance.
• To maintain high efciency of the lens, occasional cleaning of the outer lens surface may be needed, with frequency dependent on local conditions.
• Use a mild soap or detergent, which is essentially neutral pH (pH approximately 6 to 8), nonabrasive, and which contains no chlorinated or aromatic
hydrocarbons.
• Wash thoroughly, using a soft cloth.
• Rinse with clean, cold water and wipe dry.
STORAGE
6
• Prior to installation, units should NOT be stored outside in corrugated boxes (cardboard boxes) alone.
• Until installation, all units should be placed in a covered dry storage area. The storage area should not exceed -40°C (-40°F) to 50°C (122°F).
- This can be preferably in a roofed area or with a tarp that is secured in such a way to keep water off of the corrugated boxes (cardboard boxes).
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufciently for the purchaser’s purposes, the matter should be referred to GE Lighting.
GE Lighting • 1-888-MY-GE-LED (1 - 888 - 69 - 43 - 533) • www.gelighting.com
GE Lighting is a subsidiary of the General Electric Company. Evolve and the GE brand and logo are trademarks of the General Electric Company. © 2014 GE Lighting. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
35-201578-225 (Rev 10/23/14)