READ THOROUGHLY BEFORE INSTALLING
Lighting Solutions
WARNING
Risk of electric shock
Turn power off before servicingsee instructions
GENERAL
This luminaire is designed for use in outdoor applica­tions and must adhere to 25°C Max ambient temperature limitation. Install and maintain it according to the following recommendations.
the National Electrical Code and any applicable
local code requirements.
Verify that supply voltage is correct by comparing it
to nameplate.
CAUTION
Unit will fall if not installed properly
Follow installation instructions
GEH-5757D
INSTRUCTIONS
GE Edison V Luminaire
TRADITIONAL
COLONIAL
GLOBE
IF SINGLE VOLTAGE:
All single voltage ballasts are pre-wired such that user need only connect the supply conductors.
IF MULTIVOLT: (120/208/240/277 volts)
Connect the ballast lead with the insulated terminal to the desired voltage terminal as indicated on the ballast terminal nameplate.
IF MULTIWATT:
Multiwatt ballasts are available in various combinations of wattage. See wiring instructions on wiring tag inside the luminaire.
GLOBE
TRADITIONAL
STANDARD
GLOBE
BALLAST COVER
OPTIONAL OUTLET RECEPTACLE When used the access door should be re-installed with the plug cord positioned through wire way.
Wire way for optional outlet receptacle
LINE
GROUND
LINE OR NEUTRAL
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to GE Lighting Solutions.
TERMINAL BOARD
MOUNTING SET SCREWS (3 FURNISHED) TORQUE TO 18-22 FOOT-POUNDS
GLOBE SET SCREWS (FURNISHED)
BASE CASTING
OPTIONAL PHOTO CONTROL (Ordered separately) Rotate base casting so that PE window points away from other light sources.
ACCESS DOOR Remove door to install power
connections and optional photo control.
LAMPS
CAUTION
Risk of burn
Allow lamp/fixture to cool before
handling
Use only lamps specified on nameplate. Observe
lamp manufacturer’s recommendations and restric-
tions on lamp operation, particularly ballast type,
burning position, etc.
LAMP TIGHTNESS: The lamp should be securely inserted to NEMA-EEI specified torque of 35 inch­pounds, which is best achieved by very firmly tightening to insure application of sufficient torque. Tightening must be sufficient to fully depress and load center contact of socket.
MAINTENANCE
Clean globe by washing with mild non-abrasive deter­gent solution. Rinse with clean water.
g
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
GE Lighting Solutions is a subsidiary of the General Electric Company. Evolve and other trademarks belong to GE Lighting Solutions. The GE brand and logo are trademarks of the General Electric Company. © 2011 GE Lighting Solutions. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
16943533----888
35-201578-W2 (6/04) GELS