GE DBLR333EG7WW, DBSR463EG7WW, DBXR300EG6WS, DBXR463EG0CC, DBXR463EG0WW Installation Guide

...
nstallati nst cti
Questions on Installation? Call" 1-800-GECARES (US)
lectric
or Visit our Web site at: www.GEAppliances.com (US)
Drye
BEFOREYOU BEGIN
Read these instructions completely and
e
IMFORTANT- S.,,ethese
instructions fbr local inspector's use.
"IMPORTANT- Obse,,,e
all governingcodes and ordinances°
* Note to Installer- Be sure to leave these
instructions with the custotner.
* Note to Customer - Keep these instruc>
ions with your Use and Care Book for furore reference.
* Before the old dryer is removed flom
service or discarded, remove the d_Ter door.
* Service infbrmation and the wiring dia-
gram are located in the control console.
* Do not allow children on or in the appli-
ance. Close supe_wision of children is necessa_ T when the appliance is used
near children.
* Install the (bTer where the temperature
is above 50°F for satisfilctory operation of the d_Ter control system.
kWARN I N G RIsKOF
* To reduce the risk of severe i_i m T or death, fbllow all installation instruc-
tions.
* Clothes d_Ter insmlla6on must be performed by a qualified installer. * Install the clothes d_Ter according to these instructions and in accordance
with local codes.
* This d_Ter must be exhausted to the outdoors. * Use only 4" rigid metal duc6ng for exbaus6ng the clothes d_Ter to the
outdoors.
* DO NOT install a clothes d,Ter with flexible plastic ducdng materials. If
flexible metal (semi-rigid or fbil-type) duct is installed, it must be UL listed and installed in accordance with the instructions found in "Connecting The D,Ter To House Vent" on page 5 of this manual. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct dryer airflow and increase the risk of fire.
* Do not install or store this appliance in any location where it coukt be
exposed to water and or weather.
* Save these instructions. (Installers: Be sure to leave these instructions with
the customer).
NOTE: installation and service of this dryer requires basic mechanical and electrical skills, it is your responsibility to
contact a qualified installer to make the electrical connections.
TOOLS YOU
WiLL NEED
SLIPJOINTPLIERS
FLATBLADESCREWDRIVER
PHILLIPSSCREWDRIVER
%
Step 1
Step 2
Step 3 Step 4 Step 5 Step 6 Step 7
Prepare the Area and Exhaust for Installation of New Dryer (see section 1).
Check and Ensure the Existing External Exhaust is Clean (see sec6on 1) and Meets Attached Installa6on Specifications (see sec6on 3).
Remove the Foam Shipping Pads (see sec6on 1). Move the DtTer to the Desired Location.
Connect the Power Supply (see secdon 2).
Connect the External Exhaust (see secdon 4). Level Your D_Ter (see sec6on 5).
MATERIALS YOU
)
4" DIA.METALDUCT
(RECOMMENDED)
4"DIA,FLEXIBLEMETALSEMI-RIGID)
ULLSTEDTRANSTONDUCT
KITWXO8X10077(INCLUDES2ELBOWS)
4"DIA.FLEXIBLEMETALFOILTYPE)
(IFNEEDED)
ULLSTEDTRANSTONDUCT
(IFNEEDED.)
4"DUCT
CLAMPS(2)
OR
4"SPRING
CLAMPS(2)
WiLL NEED
%
4"DIA.METAL
ELBOW
DUCTTAPE
Step 8
Step 9
For Alcove or Closet Installation, see section 6. For Bathroom or Bedroom Installation, see section 7.
For Mobile or Manufi_cmred Home see, section S. For side or bottom exhaust, see section 9.
EXHAUST SAFETY
HOOD GLASSES
3/4"STRAIN
GLOVES RELIEF
ULRECOGNIZED
Check the Operation of the Power Supply
an d Ve n tin g.
Place the Owners Manual and the Installation Instructions in a Locadon Where They Will Be
Noticed By the Owner.
DRYERPOWER
CORDKIT
(NOTPROVIDED
WITHDRYER)
ULRATED 120/240V,30A
WITH3OR4PRONGS. IDENTIFYTHEPLUG TYPEASPERTHE HOUSERECEPTACLE BEFOREPURCHASING LINECORD.
Installation instructions
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance m combustible surfhces and for air opening are: 0 in. clearance bod_ sides and 1 in. rear. Consideration must be given m provide adequate clearance ff)r installation and service.
I-f] PREPARING FOR iNSTALLATiON
OF NEW DRYER
TIP: Install your dryer before installing your washer, This will allow better access when installing dryer exhaust.
REMOVING LiNT FROM WALL
EXHAUST OPENING
* Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition duct°
WALL
/
INTERNALDUCT
OPENING DAMPEROPENS
CHECKTHATEXHAUST
ANDCLOSESFREELY.
TILTTHEDRYERSIDEWAYS ANDREMOVETHEFOAM SHIPPINGPADSBY PULLINGATTHESIDES ANDBREAKINGTHEM AWAYFROMTHEDRYER LEGS.BESURETO REMOVEALLOFTHE FOAMPIECESAROUND THELEGS.
[_ ELECTRICAL CONNECTION
iNFORMATiON
A
WARNING- TO REDUCE THE RISK OF
FIRE, ELECTRICAL SHOCKAND PERSONAL INJURY:
e DO NOT USE AN EXTENSION CORD OR AN
ADAt_ER PLUG WITH THIS APPLIANCE.
Dwer must be electrically grounded in accordance with local codes and ordinances, or in the absence of local
codes, in accordance with the NATIONAL ELECTRI- CAL CODE, ANSI/NFPA NO. 70.
ELECTRICAL REQUIREMENTS
This dryer must be connected to an individual branch circuit, protected by the required time-delay fllses or circuit breakers. A Ibm or three-wire, single phase, 120/240V or 120/208V, 60Hz,
30 amp circuit is required.
If the electric supply does not meet the aboxe specifications, then
call a licensed electrician.
GROUNDING INSTRUCTIONS
This dryer must be connected to a grounded metal, permanent wiring system, or an equipmen/-grounding conductor must be run with the circuit conductors and connected to the equipment- grounding terminal on the appliance.
CONNECTING DRYER USING 4-WIRE CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTES: Since January 1,1996, the National Electric code requires that the new constructions utilize a 4-wire connection to
an electric dryer
t_WARNING:only a 4-conductor cord shah be used when the
appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for the new branch-circuit installations, mobile homes, recreational vehicles, and areas where local codes prohibit grounding through the neutral conduction.
REMOVEGROUNDSTRAP - ANDDISCARD,KEEPGREEN
GROUNDSCREW WIRE RELOCATEGREEN
HOT-"'_
GROUNDSCREW HERE
GREENOR
2
Installation
Instructions
i. Turn off the circuit breaker (s) (30 amp) or remox e tlle ch):er's
circuit fuse at the electrical box.
2. Be sure the ch):er cord is unplugged from tile wall receptacle.
3. Remox e tile power cord coxer located at the lower back.
4. Remox e and discard ground strap. Keep tlle green ground screw for step 7.
5. Install 3/4 in. LL recognized strain relief to power
cord entl_ hole. Bring power cord through strain relief.
6. Comlect power cord as follows:
7. Attach ground wire of power cord with tile green ground
8. Properly secure power cord to strain relief.
9. Reinstall tile co_ er.
A. Comlect the 2 hot lines to tile outer screws of
tlle terminal block (marked L1 and L2).
B. Com_ect tlle neutral (white) line to tile center of
tile terminal block (marked N).
screw (hole aboxe strain relief bracket). Tighten all
terminal block screws (3) completely.
_ILWARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK,
CONNECTING DRYER USING 3-WIRE CONNECTION
IFREQUIRED,BYLOCALCODE, INSTALLEXTERNALGROUND
(NOTPROVIDED)TOGROUNDED
METAL,COLDWATERPIPE,OR
OTHERESTABLISHEDGROUND
DETERMINEDBYAQUALIFIED
ELECTRICIAN.
_ 3/4",UL
GREEN GROUND GROUND STRAP
SCREW HOT
WIRE
STRAINRELIEF BRACKET
RECOGNIZED
RELIEF
EXHAUST INFORMATION
_WARNING - IN CANADA AND IN THE UNITED
STATES, THE REQUIRED EXHAUST DUCT DIAMETER
IS 4 IN (102ram). DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE.
Lsing exhaust longer than specified length wilh
" Increase the drying times and tile energy cost. , Reduce the ch)_er life.
The correct exhaust installation is YOUR RESPONSIBILITY. Problems due to incorrect installation are not covered
by the warranty.
Remove and discard existing plastic or metal foil transition duct and replace with LL listed transition duct.
Tlle MAXIML M ALLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct, number of turns, the type of exhaust hood (wall cap), and all conditions noted below. The maximum duct length for rigid
metal duct is shown in the table below.
, Accumulate lint, creating a potential fire hazard.
EXHAUST LENGTH
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended Use only for short
No. of 90 -0 Rigid Rigid
Elbows Metal Metal
0 90 Feet 60 Feet
1 60 Feet 45 Feet 2 45 Feet 35 Feet 3 35 Feet 25 Feet 4 25 Feet 15 Feet
run installations
4" DIA.
_ 2-1/2"
NEUTRAL (White) WIRE
3#10AWGMINIMUMCOPPER
COVER CONDUCTORSOR120/240V30APOWER
SUPPLYCORDKITMARKEDFORUSE WITHDRYERS& PROVIDEDWITHCLOSED
LOOPORSPADETERMINALSWITH UPTURNEDENDS(NOTSUPPLIED).
i. Tm'n off tile circuit breaker(s) (30 amp) or remo_ e tile ch_er's
circuit fuse at the electrical box.
2. Be sure the ch_er cord is unplugged Kom the wall.
3. Remoxe the power cord coxer located at tile lower back.
4. Install 3/4 in. LL recognized strain relief to power cord entl?_ bole. Bring power cord through strain relief.
5. Connect power cord as follows:
A. Com_ect the 2 hot lines to the outer screws of tile
terminal block (marked L1 and L2).
B. Com_ect the neutral {white) line to tile center of
the terminal block {marked N).
6. Be sure grotmd strap is com_ected to neutral (center) terminal of block and to green ground screw on cabinet rear. Tighten all terminal block screws (3) completely.
7. Properly secure power cord to strain relief.
S. Reinstall tile co_ er.
A
HOT
,AHb_WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL (AP
Terminate in a manner to prevent back drafts o1 entry of birds or other wildlife.
Termination should present minimal resistance to the exhaust air flow and should require little or no maintenance to prevent clogging.
Never install a screen in or over the exhaust duct.This could cause lint build up.
Wall caps must be installed at least 12 in. above ground level or any other obstruction with the opening pointed down.
SEPARATION OF TURNS For best performance, separate all turns by at least 4 ft. of straight duct,
including distance between last ttHn and exhaust hood. TURNS OTHER THAN 90°
* Oile tt_in of 45 ° or less may be ignored.
* TWO45 ° ttH'i1S should be treated as one 90 ° ttH'i1.
, Each ttH'n over 45 ° should be treated as one 90 ° ttwn.
SEALING OF JOINTS
_Mljoints should be tight to avoid leaks. The male end of each section of duct must point away flom the dryer.
Do not assemble the d uctwork with fasteners that extend into the d t_ct.
They will serve as a collection point for lint.
Duct joints can be made air and moisture-tight by wrapping the
overlapped joints with d t_ct rope.
Horizontal runs should slope down toward the outdoors inch per foot
INSULATION Duct work that runs through an unheated area or is near air conditioning
should be insulated to reduce condensation and lint build-up.
3
Installation
[-4-]EXHAUST CONNECTION
_ WARNING - TO REDUCE THE RISK
OF FIRE OR PERSONAL INJURY:
* This clothes dIyer must be exhausted to the outdoors. * Use only 4" rigid metal ducting for the home exhaust
duct.
. Use only 4" rigid metal or UI,-listed flexible metal
(semi-rigid or foil-type) duct to connect the d_Ter to the
home exhaust duct. It must be installed in accordance
with the instructions found in "Connecting The Dryer To House Vent" on page 5 of this manual.
* Do not terminate exhaust in a chimney, a wall, a
ceiling, gas vent, crawl space, attic, under an enclosed
floor, or in any other concealed space of a building° The accumulated lint could create a fire hazard.
* Never terminate the exhaust into a common duct with
a kitchen exhaust system. A combination of grease and lint creates a potential fire hazard.
* Do not use duct longer than specified in the exhaust
length table. Longer ducts can accumulate lint,
creating a potential fire hazard.
* Never install a screen in or over the exhaust duct. This
will cause lint to accumulate, creating a potential fire
hazard.
* Do not assemble ducta, vork with any fasteners that
extend into the duct. These fasteners can accumulate
lint, creating a potential fire hazard.
* Do not obstruct incoming or exhausted air. * Provide an access for inspection and cleaning of the
exhaust system, especially at turns and joints. Exhaust
system shall be inspected and cleaned at least once a year.
THiS DRYER COMES READY FOR REAR
EXHAUSTING. iF SPACE iS LiMiTED, USE
THE iNSTRUCTiONS iN SECTION 9 TO
EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET.
STANDARD REAR EXHAUST
{Vented at floor level)
instructions
STANDARD REAR EXHAUST
{Vented above floor level)
ELBOWHIGHLY
_ RECOMMENDED
RECOMMENDED CONFIGURATION
TOMINIMIZE
EXHAUST BLOCKAGE.
ELBOWHIGHLY RECOMMENDED--
=
NOTE: ELBOWS WiLL PREVENT DUCT
KiNKiNG AND COLLAPSING.
[_ LEVELING AND STABiLiZiNG
YOUR DRYER
STANDTHEDRYERUPRIGHTNEARTHEFINALLOCATIONANDADJUST THE4LEVELINGLEGS,ATTHECORNERS,TOENSURETHATTHEDRYER
ISLEVELFROMSIDETOSIDEANDFRONTTOREAR.
LEVEL FRONT-TO-BACK.
LEVEL SIDE-TO-SIDE.
FORSTRAIGHTLINEINSTALLATION, CONNECTTHEDRYEREXHAUSTTO
THEEXTERNALEXHAUSTHOOD USINGDUCTTAPEORCLAMP.
EXTERNAL DUCT
OPENING
DUCTTAPEOR DUCTCLAMP
4"METALDUCT (CUTTOPROPER
LENGTH)
NOTE:WESTRONGLYRECOMMENDSOLIDMETALEXHAUSTDUCTING. HOWEVER,IFFLEXIBLEDUCTINGISUSEDITMUSTBEUL-LISTEDMETAL
NOTPLASTIC.
DUCTTAPEOR DUCTCLAMP
4LEVELING LEGS
4
Installation instructions, indoor Exhausting
CONNECTING THE DRYER
TO HOUSE VENT
RIGID METAL TRANSITION DUCT * For best dxying perfk_rmance, a rigid metal transition
duct is recommended.
* Rigid metal transitions ducts reduce the risk of crush-
ing and kinking.
UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT * If rigid metal duct cannot be used, then Ul,-listed
flexible metal (semi-rigid) ducting can be used (Kit WX08X10077).
* Never install flexible metal duct in walls, ceilings, floors
or other enclosed spaces.
* Total length of flexible metal duct should not exceed 8
feet (2.4m).
* For many applications, installing elbows at both the
diyer and the wall is highly recommended (see illustra- tions below). Elbows allow the d_yer to sit close to the
wall without kinking and or crushing the transition duct, maximizing d,ying perf_rmance.
* Avoid resting the duct on sharp objects.
UL-LISTEDFLEXIBLEMETAL(FOIL-TYPE)TRANSITION DUCT * In special installations, it may be necessai T to connect
the d_Ter to the hot_se vent using a flexible metal (fkfil- type) dt_ct. A UL-listed flexible metal (fkfil-type)dt_ct
may be t]sed ONIX in installations where rigid metal or flexible metal (semi-rigid) ducfing cannot be used AND
where a 4" diameter can be maintained throughout the entire length of the transition dt_ct.
* In Canada and the United States, only the flexible
metal (f_il-type) ducts that comply with the "Outline f_r Clothes D_yer Transition Duct Subject 2158A" shall be
used.
*Never install flexible metal duct in walls, ceilings, floors
or other enclosed spaces.
*Total length of flexible metal duct should not exceed 8
feet (2.4m).
*Avoid resting the duct on sharp objects. *For best drying perf_rmance:
]. Slide one end of the duct over the clothes dryer
outlet pipe.
2. Secure the duct with a clamp.
3. With the d_yer in its permanent position, extend the duct to its fifll length. Allow 9" of duct to overlap the exhaust pipe. Cut offand remove excess duct. Kee I) the duct as straight as possible t_r maximum airflow.
4. Secure the duct to the exhaust pipe with the other clamp.
ELBOWHIGHLY RECOMMENDED
__ SHIGHLY I
MENDED
ALCOVE OR CLOSET iNSTALLATiON
* If yore" dlTer is approved for installation in an alcove or
closet, it will be stated on a label on the dryer back.
° The dryer MUST be vented to the outdoors. See the
EXHAUST INFORMATION sections 3 & 4.
* Minimmn clearance between duer cabinet and adjacent
walls or other surfaces is:
0 in. either side
3 in. Kont and rear
* Minimmn vertical space from floor to overhead cabinets,
ceiling, etc. is 52 in.
* Closet doors must be iouvered or othetwvise ventilated and
must contain a minimum of 60 sq. in. of open area equally distributed. If the closet contains both a washer and a
duet, doors must contain a minimum of 120 sq. in. of open area equally distributed.
BATHROOM OR BEDROOM
INSTALLATION
* The dryerMU ST be vented to the outdoors. See
EXHAUST INFORN_TION section 3 & 4.
* The installation must conform with local codes or, in the
absence of local codes, with the NATIONAL ELECTRI- CAL CODE, ANSI/NFPA NO. 70.
FSqMOBILE OR MANUFACTURED
HOME INSTALLATION
° Installation must conform to the MANUFACTURED
HOME CONSTRUCTION & SAFETY STANDARD,
TITLE 24, PART 32-80 or, when such standard is not
applicable, with %MERICAN NATIONAL STANDARD
FOR MOBILE HOME, ANSI/NFPA NO. 501B.
° The dryer MU ST be vented to the outdoors with the
termination securely fastened to the mobile home
structure. (See EXHAUST INFORMATION section 3 & 4.)
* The vent MUST NOT be terminated beneath a mobile or
mam_factured home.
* The vent duct material MU ST BE METAL. * Do not use sheet metal screws or other fastening devices
which extend into the interior of the exhaust vent.
* See section 2 for electrical connection information.
5
Installation Instructions
I-9-]DRYER EXHAUST TO RIGHT, LEFT
OR BOTTOM CABINET
A
WARNING- BEFORE PERFORMING
THIS EXHAUST INSTALLATION, BE SURE TO DISCONNECT THE DRYER FROM ITS
ELECTRICAL SUPPLY. PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET. BE SURE TO WEAR GLOVES
REMOVE SCREW ANDSAVE.
REMOVE DESIRED KNOCKOUT
(ONEONLY).
Detach and remove the bottom, right or left side knockout as desired. Remove the screw inside the dryer exhaust duct
and save. Pull the duct out of the dryer.
FIXINGHOLE
\
ADDING NEW DUCT
FIXING HOLE
PORTION"A"
RIGHTOR LEFTSIDE EXHAUST
Reconnect the cut portion (A) of the duct to the blower housing. Make sure that the shortened duct is aligned with the tab in the base. Use the screw saved previously to secure the duct in place through the tab on the appliance base.
ADDING ELBOW AND DUCT FOR
EXHAUST TO LEFT OR RIGHT
SIDE OF CABINET
Preassemble 4" elbow with 4" duct. Wrap duct tape
around joint.
Insert duct assembly, elbow first, through the side opening
and connect the elbow to the dryer internal duct.
CAUTION: Be sure not to pull or damage the
electrical wires inside the dryer when inserting the duct.
B A
9"
Cut the duct as shown and keep portion A.
TAB LOCATION
BENDTAB UP45o
Through the rear opening, locate the tab in the middle of the appliance base. Lift the tab to about 45° using a fiat
blade screwdriver.
J_
BEADDEDTO LEFTORRIGHTSIDE
EXHAUSTCAN
. TAPE
...... J-
Apply duct tape as shown on the joint between the dryer
internal duct and the elbow.
DUCT
CAUTION:
Internal duct joints must be
__ secured with tape, otherwisethey may separate and cause
6
a safety hazard.
DUCT
Installation
Instructions
ADDING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET
* Insert tile elbow through the rear opening and connect it
to the dryer internal duct.
* Apply duct tape oil thejoim between tile dryer internal
duct and elbow, as shown oil page 6.
CAUTION:
Internal duct joints must be secured with tape, otherwise they may separate and cause a safety hazard.
ADDING COVER PLATE TO REAR OF CABINET (SIDES AND BOTTOM EXHAUST)
CHANGING DIRECTION OF
DOOR OPENING
1. Open the door and remove the filler plugs opposite the
hinges. With the door completely open, remove the bottom screws from each hinge on the dryer face. Insert these screws about half way into the TOP holes, for each hinge on the opposite side (where you removed the filler plugs). Apply firm pressure to get the screw started.
2. Loosen the top screws from each hinge on the dryer face half way. With one hand hoMing the top of the door and the other hand holding the bottom, remove the door from the dD'er by lifting itUP and OUT.
3. Rotate the door 180 °. Insert the door on the opposite side of the opening by moving the doorlN and DOWN mltil the top hinge and the bottom hinge are resting on the top screws inserted in step 1.
4. Remove the remaining screws from the side of the opening from which the door was removed. With these screws secure each hinge at the bottom. Tighten the two top screws on each hinge. Reinsert the plastic plugs on
the side from which the door was removed.
REMOVETHE BOTTOMSCREW FROMEACHHINGE ONTHEDRYER
LOOSENTHETOP SCREWSFROM EACHHINGEON THEDRYERFACE HALFWAY.
÷
PLATE (KITWE1M454)
Connect standard metal elbows and ducts to complete the exhaust system. Cover back opening with a plate (Fdt WEIM454) available from your local service provider. Place dryer in final location.
_ WARNING-NEVER LEAVETHE BACK ]
OPENING WITHOUT THE PLATE. (KitWglM454)
TO REGISTER YOUR DRYER
CALL TOLL-FREE
1-888-269-1192
Prompt registration confirms your right to protection under the
terms of your warranty.
www.GEAppliances.com (US)
For Questions on Installation, Call: 1-800-GECARES (US)
5(t(t,\4 _tiPO05 Re'J) Pub # 31 16224 7
_.__FAC_
MOVETHEDOORINAND DOWNUNTILTHETOPHINGE ANDTHEBOTTOMHINGEARE
RESTINGONTHETOPSCREWS
INSERTEDINSTEP1.
SECUREEACHHINGE
ATTHEBOTTOMAND
TIGHTENTHETWOTOP SCREWSOFEACHHINGE.
SERVICING
WARNING- LABEL ALL WIRES
PRIOR TO DISCONNECTING WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION AFTER
SERVICING/INST ALIATION.
For servicing t)hone numbers for replacement parts, and
other information, refer to Owner's Manual or visit our
Web sire.
Notes
Loading...