GE DBLR333EE0CC, DBLR333EE0WW, DBLR333EE1CC, DBLR333EE1WW, DBLR333EE2CC Installation Guide

...
Installation
ElectricDryer
Instructions
Questions on Installation? Call: 1-8OO-GECARES (US)
I
BEFOREYOU BEGIN
IMPORTANT -Savethese
instructions for local inspector's use.
IMPORTANT -Observeall
governing codes and ordinances.
Note to Installer - Be sure to leave these instructions with the customer.
Note to Customer - Keep these instructions with your Use and Care Book for furore reference.
Exhausting the dryer to the outdoors is strongly recom-
mended to prevent large amounts of moisture from being blown into the room.
Before the old dryer is removed from service or discarded, remove the dryer door.
Service information and the wiring diagram are located in the control console.
Do not allow children on or in the appliance. Close supervision of children is necessary when the appliance is
used near children.
or Visit our Web site at: www.GEAppliances.com (US)
37
I
FORYOUR SAFETY:
WARNING
Use only rigid metal or flexible metal 4-in. diameter ductwork for exhausting to tile outdoors. Never use plastic or other combustible, easy-to-puncture ductwork.
This appliance must be properly grounded and installed as described in these instructions.
Do not install or store appliance in an area where it will be exposed to water and/or weather
Install tile dryer where the temperature is above ,50°F for satisfactory operation of the dryer control system.
NOTE: Installation and service of this dryer requires basic mechanical and electrical skills. It is your responsibility to contact a qualified
installer to make the electrical connections,
TOOLS YOU
WILL NEED
SLIPJOINTPLIERS
[_
FLATBLADESCREWDRIVER
PHILLIPSSCREWDRIVER
Step 1
Step 2
Step 3 Step 4 Step 5 Step 6 Step 7
Prepare the Area and Exhaust for Installation of New Dryer (see section 1).
Check and Ensure the Existing External Exhaust is Clean (see section 1) and Meets Attached Installation
Specifications (see section 3). Remove the Foam Shipping Pads (see section 1). Move the Dryer to the Desired Location.
Connect the Power Supply (see section 2).
Connect the External Exhaust (see section 4). Level Your Dryer (see section ,_).
MATERIALSYOU WILL NEED
4" DIA.METALDUCT
(RECOMMENDED) DUCT
4"DIA.FLEXIBLEMETALDUCT
(IFNEEDED)
4" CLAMPS(2)
OR 4"SPRING CLAMPS(2)
%
4"DIA.METAL
ELBOW
DUCTTAPE GLOVES ULRECOGNIZED
EXHAUSTHOOD SAFETYGLASSES
(NOTPROVIDED
ULRATED120/240V,30A
_ 3/4"_RELIEF
Step 8
Step 9
Check the Operation of the Power Supply and Venting.
Place the Owners Manual and the Installation Instructions in a Location Where They Will Be
Noticed By tile Owner.
For Alcove or Closet Installation, see section 6. For Bathroom or Bedroom Installation, see section 7.
For Mobile or Manufactured Home see, section 8. For side or bottom exhaust, see section 9.
WITH3OR4PRONGS.
IDENTIFYTHEPLUGTYPE
ASPERTHEHOUSE
RECEPTACLEBEFORE PURCHASINGLINECORD.
DRYERPOWER
CORDKIT
WITHDRYER)
Installation Instructions
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration must be given to provide adequate clearance for installation and service.
[] PREPARING FOR INSTALLATION
OF NEW DRYER
EXTERNAL DUCT OPENING
DUCTTAPEOR DUCTCLAMP
4"METALDUCT
DUCTTAPEOR DUCTCLAMP
TIP: Install your dryer before installing your washer. This will allow better access when installing dryer exhaust.
REMOVING LINT FROM WALL EXHAUST OPENING
[] ELECTRICAL CONNECTION
INFORMATION
WARNING- TO REDUCE THE RISK OF
FIRE, ELECTRICAL SHOCK AND PERSONAL INJURY:
DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE.
Dryer must be electrically grounded in accordance with local codes and ordinances, or in the absence of local
codes, in accordance with the NATIONAL ELECTRI- CAL CODE, ANSI/NFPA NO. 70.
ELECTRICAL REQUIREMENTS
This dryer must be connected to an individual branch circuit, protected by the required time-delay fuses or circuit breakers. A
four or three-wire, single phase, 120/240V or 120/208V, 60Hz, 30 amp circuit is required.
If the electric supply does not meet the above specifications, then call a licensed electrician.
GROUNDING INSTRUCTIONS
This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-gxounding conductor nmst be nm with the circuit conductors and connected to the equipment- grounding terminal on the appliance.
INTERNALDUCT
WALL
CHECKTHATEXHAUST
DAMPEROPENS
ANDCLOSESFREELY.
TILTTHEDRYERSIDEWAYS ANDREMOVETHEFOAM SHIPPINGPADSBY PULLINGATTHESIDES ANDBREAKINGTHEM AWAYFROMTHEDRYER LEGS.BESURETO REMOVEALLOFTHE FOAMPIECESAROUND THELEGS,
CONNECTING DRYER USING 4-WIRE CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION)
NOTE: Since January 1, 1996, the National Electric Code requires that new constructions utilize a 4 wire connection
to an electric dryer.
REMOVEGROUNDSTRAP- ANDDISCARD.KEEPGREEN GROUNDSCREW
HOT WIRE RELOCATEGREEN
GROUNDSCREW HERE
GREENOR
2 WITHUPTURNEDENDS(
Installation Instructions
1. Turn off the circuit breaker (s) (30 amp) or remove the dryer's circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from tile wall receptacle.
3. Remove the power cord cover located at the lower back.
4. Remove and discard ground strap. Keep the green ground screw for step 7.
5. Install 3/4 in. UL recognized strain relief to power cord entry hole. Bring power cord through strain relief.
6. Connect power cord as follows:
7. Attach ground wire of power cord with the green ground
8. Properly secure power cord to strain relief.
9. Reinstall the coven
A. Connect the 2 hot lines to the outer screws of
the terminal block (marked L1 and L2).
B. Connect the neutral (white) line to tile center of
the terminal block (marked N).
screw (hole above strain relief bracket). Tighten all terminal block screws (3) completely.
,_WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
CONNECTING DRYER USING 3-WIRE CONNECTION
IFREQUIRED,BYLOCALCODE, INSTALLEXTERNALGROUND
(NOTPROVIDED)TOGROUNDED METAL,COLDWATERPIPE,OR GREEN GROUND
OTHERESTABLISHEDGROUNDGROUND _TRAP DETERMINEDBYAQUALIFIEDSCREW
ELECTRICIAN. HOT
WIRE
NEUTRAL (White) WIRE
3#10AWGMINIMUMCOPPER
COVER CONDUCTORSOR120/240V30APOWER
SUPPLYCORDKITMARKEDFORUSE WITHDRYERS& PROVIDEDWITHCLOSED
LOOPORSPADETERMINALSWITH UPTURNEDENDS(NOTSUPPLIED).
1. Tm'n off the circuit breaker (s) (30 amp) or remove the dryer's
circuit fuse at the electrical box.
2. Be sure the dryer cord is unplugged from the wall.
3. Remove tile power cord cover located at the lower back.
4. Install 3/4 in. UL recognized strain relief to power cord entry hole. Bring power cord through strain relief.
5. Connect power cord as Mlows:
A. Connect the 2 hot lines to the outer screws of the
terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of
the terminal block (marked N).
6. Be sure ground strap is connected to neutral (center) terminal of block and to green ground screw on cabinet
rear. Tighten all terminal block screws (3) completely.
7. Properly secure power cord to strain relief.
8. Reinstall tile cover.
,_WARNING: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
STRAINRELIEF BRACKET
3/4",UL RECOGNIZED
HOT
/
RELIEF
[] EXHAUST INFORMATION
A
JIIWARNING - USE ONLY METAL 4-IN. DUCT.
DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE.
Using exhaust longer than specified length will:
Increase the drying times and the energy cost.
Reduce the dryer life.
Accumulate lint, creating a potential fire hazard.
The correct exhaust installation is YOUR RESPONSIBILITY. Problems due to incorrect installation are not covered
by the warranty.
The MAXIMUM ALLOWABLE length of the exhaust system depends upon the type of duct, nmnber of turns, the type of
exhaust hood (wall cap), and all conditions noted below. Both rigid and flexible metal duct are shown in the table below.
EXHAUST LENGTH
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90_ Rigid Flexible Rigid Flexible
Elbows Metal Metal Metal Metal
0 90 Feet 55 Feet 60 Feet 45 Feet
1 60 Feet 40 Feet 45 Feet 30 Feet 2 45 Feet 30 Feet 35 Feet 20 Feet 3 35 Feet 20 Feet 25 Feet 15 Feet 4 25 Feet 15 Feet 15 Feet 10 Feet
If using flexible metal duct, please refer to page 5.
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
Terminate in a manner to prevent back draf& or entry of birds or other wildlifK
Termination should present minimal resistance to the exhaust air flow and should require little or no maintenance to prevent clogging.
Never install a screen in or over tfie exhaust duct. This could cause lint build up.
Wall caps must be installed at least 12 in. above g_ound level or any other obstruction with the opening pointed down.
If roof vents or louvered plenums are used, they must be equivalent to a 4-in. dampened wall cap in regard to resistance to air flow, prevention of back drafts, and maintenance required to prevent cloggting.
SEPARATION OF TURNS
For best performance, separate all turns by at least 4 ft. of straight duct, including distance between last turn and exhaust hood.
TURNS OTHER THAN 90°
One turn of 450 or less may be ignored.
Two 450 turns should be treated as one 90 ° turn.
Each turn over 45 o should be treated as one 900 turn.
SEALING OFJOINTS
All joints should be tight to avoid leaks. The male end of each section of duct must point away from the dryer.
Do not assemble the ductwork with fasteners that extend into the duct. They will serve as a collection point fbr lint.
Duct joints can be made air and moisture-tight by wrapping the overlapped joints with duct tape.
Horizontal runs should slope down toward tile outdoors 1/2 inch per foot
INSULATION Duct work that runs through an unheated area or is near air conditioning
should be insulated to reduce condensation and lint build-up.
3
Use only for short
run installations
4"DIA.
Installation Instructions
[] EXHAUST CONNECTION
,_,WARNING - TO REDUCE THE RISK
STANDARD REAR EXHAUST
(Vented above floor level)
OF FIRE OR PERSONAL INJURY:
Exhausting the dryer to the outdoors is strongly recom- mended to prevent large amounts of moisture from
being blown into the room.
Use only metal duct.
Do not terminate exhaust in a chimney, any gas vent,
under an enclosed floor (crawl space), or into an attic. The accumulated lint could create a fire hazard.
Provide an access for inspection and cleaning of the
exhaust system, especially at turns. Inspect and clean at
least once a year.
Never terminate the exhaust into a common duct with a
kitchen exhaust. A combination of lint and grease could
create a fire hazard.
Do not obstruct incoming or exhausted air.
THIS DRYER COMES READY FOR REAR
EXHAUSTING. IF SPACE IS LIMITED, USE
THE INSTRUCTIONS IN SECTION 9 TO
EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET,
STANDARD REAR EXHAUST
(Vented at floor level)
ELBOWHIGHLY
_ RECOMMENDED
RECOMMENDED
= CONFIGURATION
TO MINIMI7E
EXHAUST BLOCKAGE.
ELBOWHIGHLY RECOMMENDED
NOTE: ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING.
[] LEVELING AND STABILIZING
YOUR DRYER
STANDTHEDRYERUPRIGHTNEARTHEFINALLOCATIONANDADJUST
THE4LEVELINGLEGS,ATTHECORNERS,TOENSURETHATTHEDRYER
ISLEVELFROMSIDETOSIDEANDFRONTTOREAR.
FORSTRAIGHT LINEINSTALLATION,
CONNECTTHE DRYEREXHAUST TOTHEEXTERNAL EXHAUSTHOODUSIN( DUCTTAPEORCLAMR
CUTTHEMETALEXHAUST DUCT(NOTSUPPLIED)TOTHE
PROPERLENGTH.
LEVEL FRON_TO-BACK, LEVEL
SIDE-TO-SIDE,
4LEVELING LEGS
NOTE:WESTRONGLYRECOMMENDSOLIDMETALEXHAUSTDUCTING. HOWEVER,IFFLEXIBLEDUCTINGISUSEDITMUSTBEMETALNOTPLASTIC. 4
Installation Instructions, Indoor Exhausting
USING FLEXIBLE METAL DUCTS
If rigid allmmtal duct cannot be used, then flexible allmmtal ducting can be used, but it will reduce the maxinmnl recotmnended duct
length. In special installations when it is impossible to use only metal ducting, then ULdisted clothes dryer flexible metal transition duct may be used as transition venting between the dryer and wall connection only. The use of this ducting will affect dry time.
If flexible transition duct is necessary, the following directions must be followed.
Use the Shortest Length Possible.
Stretch the Duct to Its Maxinmm Length to avoid kinks.
Do Not Crush or Collapse the Duct.
Never Use Transition Duct Inside the Wall or Inside the Dryer.
Avoid Resting the Duct on Sharp Objects.
Venting Must Conform to Local Building Codes.
ELBOWHIGHLY RECOMMENDED
INDOOR EXHAUSTING
NOTE: MOBILE HOME, BEDROOM, BATHROOM,
ALCOVE OR CLOSET INSTALLATIONS
MUST BE EXHAUSTED TO THE OUTDOORS
OTHER INSTALLATIONS: If tile installation makes it impossible to exhaust to tile outdoors, a 4" exhaust
deflector (WE25X278) must be installed. A clearance of 8" is required between tile rear of tile dryer and the wall, and
tile deflector should be pointing up.
NOTE: EXHAUSTING TO THE OUTDOORS IS
STRONGLY RECOMMENDED, EXHAUSTING INDOORS MAY CAUSE LINT ACCUMULATION, AND MOISTURE DAMAGE INCLUDING MOLD AND MILDEW,
[] ALCOVE OR CLOSET INSTALLATION
If your dryer is approved for installation in an alcove or
closet, it will be stated on a label on the dryer back.
The dryer MUST be vented to the outdoors. See the EXHAUST INFORMATION sections 3 & 4.
Minimum clearance between dryer cabinet and adjacent walls or other surfaces is:
0 in. either side 3 in. front and rear
Minimum vertical space from floor to overhead cabinets,
ceiling, etc. is 52 in.
Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally
distributed. If the closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open
area equally distributed.
DONOTUSE EXCESSIVE EXHAUST
ELBOWSHIGHLY
)(
)(
b ONOT
CRUSH FLEXIBLE
EXHAUST
AGAINST WALL._
)
[] BATHROOM OR BEDROOM
INSTALLATION
The dryer MUST be vented to the outdoors. See
EXHAUST INFORMATION section 3 & 4.
Tile installation must conform with local codes or, in the
absence of local codes, with the NATIONAL ELECTRI-
CAL CODE, ANSI/NFPA NO. 70.
[] MOBILE OR MANUFACTURED
HOME INSTALLATION
Installation must conform to the MANUFACTURED
HOME CONSTRUCTION & SAFETY STANDARD,
TITLE 24, PART 32-80 or, when such standard is not applicable, with AMERICAN NATIONAL STANDARD
FOR MOBILE HOME, ANSI/NFPA NO. 50lB.
The dryer MUST be vented to the outdoors with the
termination securely fastened to the mobile home structure. (See EXHAUST INFORMATION
section 3 & 4.)
The vent MUST NOT be terminated beneath a mobile or manufactured home.
The vent duct material MUST BE METAL.
Do not use sheet metal screws or other fastening devices which extend into the interior of the exhaust vent.
See section 2 for electrical connection information.
5
Installation Instructions
[] DRYER EXHAUST TO RIGHT, LEFT
OR BOTTOM CABINET
iF=
I/A,WARNING- BEFORE PERFORMING
THIS EXHAUST INSTALLATION, BE SURE TO DISCONNECT THE DRYER FROM ITS
ELECTRICAL SUPPLY. PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES
WHEN WORKING INSIDE THE CABINET.
BE SURE TO WEAR GLOVES
REMOVE SCREW
ANDSAVE.
REMOVE DESIRED KNOCKOUT (ONEONLY),
Detach and remove the bottom, right or left side knockout as desired. Remove the screw inside the dryer exhaust duct and save. Pull the duct out of the dryer.
FIXINGHOLE
ADDING NEW DUCT
FIXING HOLE
_ PORTION"A"
RIGHTOR LEFTSIDE
EXHAUST
Reconnect tile cut portion (A) of tile duct to tile blower housing. Make sure that the shortened duct is aligned with the tab in tile base. Use the screw saved previously to secure tile duct in place through the tab on tile appliance base.
ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT OR RIGHT SIDE OF CABINET
Preassemble 4" elbow with 4" duct. _¥rap duct tape around joint.
Insert duct assembly, elbow first, through tile side opening
and connect tile elbow to the dryer internal duct.
CAUTION: Be sure not to pull or damage the
electrical wires inside the dryer
when inserting the duct.
{
B A
Cut the duct as shown and keep portion A.
TAB LOCATION
BENDTAB UP45o
Through the rear opening, locate the tab in the middle of the appliance base. Lift the tab to about 45° using a fiat
blade screwdriver.
EXHAUSTCAN BEADDEDTO
LEFTORRIGHTSIDE
\
Apply duct tape as shown on the joint between the dryer
internal duct and the elbow.
DUCT
CAUTION: Internal duct joints must be
secured with tape, otherwise they may separate and cause
6
a safety hazard.
J
DUCT
TAPE
Installation Instructions
ADDING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET
Insert the elbow through tile rear opening and connect it to
the dryer internal duct.
Apply duct tape on the joint between tile dryer internal duct and elbow, as shown on page 6.
CAUTION:
Internal duct joints must be secured with tape, otherwise they may separate and cause a
safety hazard.
ADDING COVER PLATE TO REAR OF CABINET (SIDES AND BOTTOM EXHAUST)
IT0qCHANGING DIRECTION OF
DOOR OPENING
1. ()pen tile door and remove tile filler plugs opposite tile
hinges. _¥ith tile door completely open, remove the bottom screws from each hinge on tile dryer face. Insert these screws about halfway into tile TOP holes, for each hinge on tile opposite side (where you removed tile filler plugs). Apply firm pressure to get tile screw started.
2. Loosen tile top screws from each hinge on tile dryer face halfway. _¥ith one hand holding the top of the door and the other hand holding the bottom, remove the door from the dryer by lifting it UP and OUT.
3. Rotate the door 180°. Insert the door on the opposite side of the opening by moving the door IN and DOWN until the top hinge and the bottom hinge are resting on the top screws inserted in step 1.
4. Remove the remaining screws from the side of the opening from which the door was removed. With these screws secure each hinge at the bottom. Tighten the two top screws on each hinge. Reinsert the plastic plugs on
the side from which the door was removed.
LOOSENTHETOP
REMOVETHE SCREWSFROM BOTTOMSCREW EACHHINGEON FROMEACHHINGE THEDRYERFACE ONTHEDRYER HALFWAY.
Connect standard metal elbows and ducts to complete tile
exhaust system. Cover back opening with a plate (Kit WE 1M454) available from your local service provider. Place dryer in final location.
- NEVER LEAVE THE BACK I
OPENING WITHOUT THE PLATL (KitWE1M454)I
TO REGISTER YOUR DRYER
CALL TOLL-FREE
1-888-269-1192
Promptregistrationconfirmsyour rightto protectionunderthe
termsof yourwarranty.
www.GEAppliances.com (US)
For Questions on Installation, Call: 1-800-626-2003 (US)
500A187PO_7 2 Ill ()N Ihlb # 31 15175
MOVETHEDOORINAND DOWNUNTILTHETOPHINGE ANDTHEBOTTOMHINGEARE RESTINGONTHETOPSCREWS INSERTEDINSTEP1,
SECUREEACHHINGE
ATTHEBOTTOMAND TIGHTENTHETWOTOP
SCREWSOFEACHHINGE.
[] SERVICING
_k WARNING- LABEL ALL WIRES
PRIOR TO DISCONNECTING WHEN
SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION AFTER
SERVICING/IN STALLATION.
For servicing phone numbers for replacement parts, and
other information, refer to Owner's Manual or visit our
Web site.
7