DSXH43GVWW—GE 6.0 Cu. Ft. Capacity Spacemaker®Gas Dryer
GE Appliances
Specification Revised 6/00
Dryer Dimensions (in inches)
Dryer Installation Options
Exhaust Options:
Gas—3-way via rear, right and bottom. Dryer is shipped exhausted to the rear. Alternate
exhausting knockouts are supplied.
Gas Dryer Electric Rating: 120V, 60Hz, 6A
An individual properly-grounded branch circuit, with a three-prong grounding-type receptacle,
protected by a 15 or 20 amp circuit breaker or a time-delay fuse is required.
Gas (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas supply
requires a conversion kit. Check installation instructions for correct kit and have a qualified
gas technician install a conversion kit. See dryer ducting information for proper installation.
Note: Dryer wall outlet must be located within 36" of service cord entry and accessible
when dryer is mounted in position.
Installation Information: For complete information, see installation instructions packed
with your dryer.
REAR VIEW
26-7/8
3-3/4
1
36
Under
Counter
34-5/8"
3/16"
Gas Pipe Connection
Electric
Connection
2-9/16
13-9/16
SIDE VIEW
25-3/4
47-1/2
4-3/4
Optional
Vent Knockout
Door Open
90°
4-3/8
3/4
27" Min.
27" Min.
70-5/8
Note:
27"
Min.
34-5/8"
Min.
Custom Sized
Countertop Required
54" Min.
Listed by
Underwriters
Laboratories
For answers to your Monogram,
®
GE Profile Performance Series,
™
GE Profile™or GE appliance questions, call
GE Answer Center®service, 800.626.2000.
Stacked in Cabinet Installation Undercounter Installation
Note:
Closet Installation Requires Additional
Minimum Clearances:
A Minimum of 120 Square Inches of Openi
Equally Divided at the Top and Bottom of
the Closet Door is Required.
.
Top of Dryer to Ceiling 15"
Back of Dryer to Wall 4"
Front of Dryer/Washer 1"
to Closet Door
R
DSXH43GVWW—GE 6.0 Cu. Ft. Capacity Spacemaker®Gas Dryer
GE Appliances
Specification Revised 6/00
Dryer Exhausting Information—Use Metal Duct Only
For complete information, see installation instructions packed with your dryer.
Ducting Materials:
For best performance, this dryer should be vented with 4” diameter all rigid metal exhaust duct. If “all rigid metal” duct cannot be used, then “flexible
all metal” venting can be used, but it will reduce the maximum recommended duct length.
Exhaust Length Calculation:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn.
2. The maximum length of 4’ rigid (aluminum or galvanized) duct which can be tolerated is shown in the table. The maximum length for flexible
ducts are less than for rigid duct.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated
as a 90° elbow.
Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room.
Gas dryers or any dryer located in a closet must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the
accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a
kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least
12” above the ground or any other obstruction with the opening pointed down. Other terminations, such as louvered wall boxes, are acceptable
provided they are equivalent to a 4” opening dampered wall cap.
For answers to your Monogram,
®
GE Profile Performance Series,
™
GE Profile™or GE appliance questions, call
GE Answer Center®service, 800.626.2000.
Listed by
Underwriters
Laboratories
Special Installation Requirements
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on
a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0” either side
3” front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
• Closet doors must be louvered or otherwise ventilated and must contain a
minimum of 60 sq. in. of open area equally distributed. If this closet contains
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open
area equally distributed.
• The closet should be vented to the outdoors to prevent gas pocketing in case of a
gas leak in the supply line.
• No other fuel-burning appliance shall be installed in the same closet with the dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.
Minimum Clearances other than Alcove or Closet Installation:
•Minimum clearances to combustible surfaces
0” both sides
3” rear
0 60 ft. 48 ft. 30 ft. 18 ft.
1 52 ft. 40 ft. 22 ft. 14 ft.
2 44 ft. 32 ft. 14 ft. 10 ft.
Front Loading 3 32 ft. 24 ft.
Dryers 4 28 ft. 16 ft.
Number
of
90°
Turns
Maximum Length of 4"
Dia.
Rigid Metal Duct
Maximum Length of 4"
Dia. Flexible Metal Duct
Exhaust Hood Type
Exhaust Hood Type
A
4" Opening
B
2-1/2"
Opening
A
4" Opening
B
2-1/2"
Opening