DSXH43EFWW
SIDE VIEW
25-3/4
47-1/2
4-3/4
Optional
Vent Knockout
Door Open
90
°
4-3/8
3/4
REAR VIEW
26-7/8
3-3/4
1
36
Under
Counter
34-5/8"
3/16"
Gas Pipe Connection
Electric
Connection
2-9/16
13-9/16
70-5/8
SIDE VIEW
25-3/4
47-1/2
4-3/4
Optional
Vent Knockout
Door Open
90
°
4-3/8
3/4
GE® Extra-Large 5.7 Cu. Ft. Capacity Frontload Electric Dryer
Dimensions and Installation Information (in inches)
Exhaust Options: Electric—4-way via rear, right, left
and bottom.
Circuit Requirements: Electric—An individual,
properly-grounded branch circuit, protected by a 30amp circuit breaker or a time-delay fuse, is required.
Electric Dryer Rating:
120/240V, 3-wire, 5600W, 24A
120/208V, 3-wire, 4400W, 22A
Note: Dryer wall outlet must be located within 36”
of service cord entry and accessible when dryer is
mounted in position.
Installation Information: For complete information,
see installation instructions packed with your dryer.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Specification Created 9/05
Listed by
Underwriters
Laboratories
360426
![](/html/93/93ee/93ee24b1a2762b485fd00c5727feaa01155358cb6505cc15604f4a4ded2774a3/bg2.png)
Washer
Top Sheet
Drye
r
Top Sheet
Countertop
14''
29''
56''-60''
Lip on All Sides
3/4" High x 3/4"
Wide
Max.
DSXH43EFWW
GE® Extra-Large 5.7 Cu. Ft. Capacity Frontload Electric Dryer
Dimensions and Installation Information (in inches)
Special Installation Requirements
Undercounter Installation
Accessory mounting kits are required for undercounter installation. To order,
call 1-800-848-7722.
Stacked Installation: Brackets for stacking dryer over washer are included with
the washer.
Alcove or Closet Installation:If your dryer is approved for installation in an
alcove or closet, it will be stated on a label on the dryer back. The dryer MUST
be exhausted to the outdoors. Minimum clearances between dryer cabinet and
adjacent walls or other surfaces are: 0" either side, 3" front and rear Minimum
vertical space from floor to overhead cabinets, ceilings, etc. is 52". Closet doors
must be louvered or otherwise ventilated and must contain a minimum of 60
sq. in. of open area equally distributed. If this closet contains both a washer
and a dryer, doors must contain a minimum of 120 sq. in. of open area equally
distributed. The closet should be vented to the outdoors to prevent gas pocketing
in case of a gas leak in the supply line. No other fuel-burning appliance shall be
installed in the same closet with the dryer.
Bathroom or Bedroom Installation: The dryer must be exhausted to the
outdoors. The installation must conform with the local codes, or in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.
Minimum Clearances other than Alcove or Closet Installations:
Minimum clearances to combustible surfaces: 0" both sides, 3" rear
Free-Standing Installation
Stacked Installation
Raised/ Built-in Installation
Undercounter Installation
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.