GE DSKS433EBWW - Spacemaker 240V Stationary Electric Dryer, DSKS433EB Spacemaker, DSKS433EBWH Spacemaker Dimensions And Installation Information

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
360432
Specification Revised 5/09
Listed by Underwriters Laboratories
DSKS433EB
GE Spacemaker® Stationary Dryer
Dimensions and Installation Information (in inches)
Shown with WSLP1100A or WSLS1100A and Stack Rack DSDR24D
WSLP1500J
Portable
Washer
or
WSLS1500J
Stationary
Washer
DSKS433EB and
DSKS333EC
Dryer
Stack Rack DSDR24D
22-7/8
1-5/8
5-1/2
20
79-1/4
38"
WSLP1500J Portable or
37-1/2"
WSLS1500J Stationary
24-1/2
25-1/2
31-1/2
Top
Vent
WSLP1100A
Stationary
Washer
DSKS333EC
Dryer
Stack Rack DSDR24D
22-7/8
1-5/8
5-1/2
20
77-3/4
38
25-1/2
Top
Vent
31-1/2
24-1/2
33-1/4
46
33-1/4
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service,
800.626.2000.
360432
Specification Revised 5/09
Listed by Underwriters Laboratories
DSKS433EB
GE Spacemaker® Stationary Dryer
Dimensions and Installation Information (in inches)
Special Installation Requirements Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other
surfaces are:
0" either side
3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
• Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces 0" both sides
3" rear
Best performance
Domestic dryer models
Maximum length of 4" dia. rigid metal duct
Number
of
90°
turns
Exhaust hood type
A
4"
opening
B
2-1/2"
opening
DSKS433EB DSKS333EC DSKP333EC WSM2780H
0 1 2 3
46 ft. 38 ft. 31 ft. 24 ft.
37 ft. 30 ft. 22 ft. 15 ft.
WSM2700H
0 1 2 3
56 ft. 46 ft. 34 ft. 32 ft.
42 ft. 36 ft. 28 ft. 18 ft.
WSM2420D WSM2480D
0 1 2
43 ft. 33 ft. 23 ft.
36 ft. 26 ft. 16 ft.